Supra-Clean® and Supra-Poly® Solid Phase Extraction (SPE) Solutions
Imagine how much faster, easier and more efficient your sample preparation would be if your Solid Phase Extraction (SPE) solutions were precisely manufactured for guaranteed reproducibility. Not just column to column. Not just batch to batch. But lot to lot—no matter how many days, weeks or years between production times. That’s exactly the kind of confidence and convenience you can expect with the innovative line of Supra-Clean™ silica-based and Supra-Poly™ polymer-based SPE cartridges and columns from PerkinElmer. Our Precise-Bed Technology™ provides precision and manufacturing tolerances of + – 1%, ensuring guaranteed repeatability and optimized recovery reproducibility. The distribution and size of particles is controlled through stringent manufacturing processes, and each finished product is delivered with an individual quality certificate. Experience the difference for yourself. Or—to be more exact— experience the uniformity.
PerkinElmer’s homogeneous filling and mono-dispersed spherical media not only provide unparalleled reproducibility, they also deliver superior performance. Sample diffusion through the media is better than in other systems, improving flow efficiency and avoiding channeling and clogging due to fines. This enables smaller sample sizes to be used without compromising recovery levels, dramatically reducing solvent volumes, analytical costs and processing times.
18
V1
6
With PerkinElmer SPE solutions, you can work faster and more costeffectively, all while experiencing the complete recovery, reproducibility and reliability you need for consistently excellent results.
V2 IR60-40/63SI
0
SPE Supra-Clean 60-50SI
2
V1 < V2 4
6
PerkinElmer’s smaller, more homogeneous, spherical media deliver sharper, narrower peaks for faster, more accurate sample analysis.
2
Spherical media and consistent particle distribution enable smaller elution volumes and better, more reproducible extraction purification, concentration and recovery.
The unsurpassed reproducibility of SPE solutions is the result of a unique bed-packing technique and spherical media. Columns are evenly and consistently filled with particles sized for optimum distribution, delivering a level of performance unattainable with the irregularly shaped silica used in competitive solutions.
250 x 4.6 mm column Hexane - IsoPropanol (97/3) Flow rate: 1.0 ml/min PSI: 1 bars UV: 254 nm A- Tri-Terbutylbenzene B- Diethyl Phthalate
12
Competitor SPE Column
Consistently. Excellent. Performance.
Performance Comparison of PerkinElmer Spherical SPE Media vs. Leading Irregular SPE Silica.
24
SPE Column
Answering Your Needs. Empowering Your Lab. Ideal for a broad array of analytes and matrices, SPE solutions are available in a variety of formats including Large Reservoir Capacity (LRC) columns, Polypropylene (PP) columns and cartridges, 96 well plate format, and glass columns. Each technology is offered with a wide selection of polymer and silica sorbents. Varied column capacities and bed weights allow you to perform scalable analyses depending upon your required detection limits.
Choose the Best SPE Solution For Your Method To find the ideal SPE column for your particular application, simply follow the flow diagram below, selecting your path based on the options at each junction.
Your Sample
Type of Matrix
Aqueous
Analyte Solubility
Water
Analyte
Analyte Polarity
Polar
Ionic
Neutral
Neutral
Anionic Acids
Ion Exchange Chromatography
Non-Polar
Reversed Phase Chromatography
Non-Polar
Polar
Normal Phase Chromatography
Supra-Clean Florisil (FL-S) Supra-Clean Silica (SI-S) Supra-Clean Amino (NH2-S) Supra-Clean Polyamine (P6)
Supra-Clean Amino (NH2-S) Supra-Poly 1200 m2/g (XWP)* Supra-Poly (ATH, ATL, AEV)* Supra-Poly HLB
Supra-Clean C18 Supra-Clean 300Å C4 Supra-Clean Phenyl (PH-S) Supra-Clean Cyano (CN-S) Supra-Poly Extreme Capacity 1500 m2/g (XC)* Supra-Poly HLB
Supra-Clean Strong Anion Exchange (SAX) Supra-Clean Amino (NH2-S) Supra-Clean Mixed-Mode (MM1) Supra-Clean Mixed-Mode (MM2)
SPE Strong Cation Exchange (SCX) SPE Weak Cation Exchange (WCX) Supra-Clean Mixed-Mode (MM3)
Supra-Clean REC18
Supra-Clean REC18
Supra-Clean C18 Supra-Clean 300Å C4 Supra-Clean Phenyl (PH-S) Supra-Clean LCC
www.perkinelmer.com/spe
Organic Solvents
Cationic Bases
Reversed Phase Chromatography
*AEV = Advanced Environmental ATH = Hydrophobic/Hydrophilic ATL = Lipophilic
Water
path as Ionic analyte)
Moderately Polar
Non-Polar
Follow same path as Organic
Ionic (Follow same
Neutral
Recommended Chromatography
Recommended SPE Products
Organic
HLB = Hydrophilic Lipophylic Balanced XC = Extreme Capacity XWP = Extra Wide Particle
3
A WIDE ARRAY OF
COLUMNS FOR A
BROAD RANGE OF
APPLICATIONS
SUPRA-CLEAN SPHERICAL SILICA
Phase Mechanism Interaction mode Compounds Matrix C18-S Hydrophobic Reversed Phase Polar to Non-Polar compounds Biological fluids, aqueous samples High Recovery REC18 Hydrophobic Reversed Phase Non-polar and mid-polar compounds Biological fluids, aqueous samples including 100% water solvents Phenyl (PH-S) Hydrophobic Reversed Phase
Non-polar to mid-polar Biological fluids aromatic compounds
Silica (SI-S) Hydrophilic Normal Phase Polar compounds Non-polar organics, oils, lipids Amino (NH2-S) Hydrophilic Normal Phase
Polar to Mid-Polar aromatic compounds
Biological fluids, aqueous samples, buffered organics
Strong Cation Ion Exchange Ion Exchange Basic compounds Biological fluids, aqueous samples, Exchange (SCX) buffered organics Weak cation Ion Exchange Ion Exchange Strong basic compounds Biological fluids, aqueous samples Exchange (WCX) Strong Anion Ion Exchange Ion Exchange Acidic compounds Biological fluids, aqueous samples Exchange (SAX) Cyano (CN-S)
Hydrophilic
Normal Phase
Polar to Mid-Polar compounds
Non-polar organics, oils, lipids
Florisil (FL-S) Hydrophilic Normal Phase Polar compounds Ideal for polar compounds in non-polar matrix
Florisil Pesticide (FL-S) Hydrophilic Normal Phase Polar compounds Ideal for polar compounds in non-polar matrix Polyamine (P6) Hydrophilic Reversed Phase
Carboxylic acids, phenolics Aqueous and mid-polar matrices and nitroaromatics
300 A (C4)
Hydrophobic
Reversed Phase
Non-polar to mid-polar compounds
Biological Samples
LCC
Hydrophobic
Reversed Phase
Non-polar to mid-polar compounds
Biological fluids, aqueous samples
Mixed mode (MM1)
Ion Exchange/ Hydrophobic
Reversed Phase / SCX
Basic compounds
Biological samples
Mixed mode (MM2)
Ion Exchange/ Hydrophobic
Reversed Phase / WCX
Very basic compounds
Biological samples
Mixed mode (MM3)
Ion Exchange/ Hydrophobic
Reversed Phase / SAX
Acidic compounds
Biological samples
SUPRA-POLY SPHERICAL POLYMER Extreme Capacity (XC)
Hydrophobic
Reversed Phase
Polar and non-polar
Aqueous or organic
Extreme Capacity Hydrophobic Reversed Phase Polar and non-polar Biological and viscous samples Wide Pore (XWP) Hydrophilic (ATH) Hydrophilic Reversed Phase Mid to non-polar compounds Aqueous or organic
Lipophilic (ATL) Lipophilic Reversed Phase Mid to non-polar compounds Crude samples Environmental (AEV) Hydrophilic/ Hydrophobic Reversed Phase Mid to non-polar compounds Aqueous or Organic HLB Hydrophilic/lipophilic balanced Reversed Phase Mid to non-polar compounds Aqueous or organic
4
Typical Applications Drugs and drug metabolites in biological matrices, trace organic material in water, toxins in food
pH Range
End- capping
Pore Size (A)
Surface Area (m2/g)
Particle Size (um)
2-8
Yes
60
500
50
Comments 18% Carbon Load (CL)
Drugs and drug metabolites in biological 2-8 Yes NA NA 50 matrices, trace organic material in water, toxins in food
High capacity and better recovery especially for high acqueous conditions. 15% CL
Benzodiazepines in biological matrices, extraction of aromatic compounds
2-8
No
60
500
50
9% CL
Aldehydes, amines, pesticides, herbicides, carotenoids, fat soluable vitamins, baflatoxins, fatty acids, and phospholipids
2-8
No
60
500
50
Bare Silica
Basic compounds, polar amine compounds, carbohydrates
2-8
No
60
500
50
5% CL
Cations, antibiotics, drugs, amino acids, 2-8 No 60 450 60 catecholamines, herbicides, nucleic acid bases, nucleosides, and surfactants
Strong Acid - Sulfonic acid; Exchange capacity 0.70 meq/g
Cations, amines, antibiotics, drugs, amino acids, 2-8 No 60 450 60 Weak Acid - Carboxylic acid; Exchange catecholamines, nucleic acid bases, nucleosides, capacity 0.22 meq/g and surfactants Acidic food pigments, organic acids, phenol 2-8 No 60 450 60 compounds, nucleic acids, nucleotides, surfactants Polar compounds in hexane and oil
2-8
Yes
60
500
50
Strong Base - quaternary amine; Exchange capacity 0.30 meq/g 8% CL; Mid-range polarity between silica and C18
Pesticides, Polychlorinated Biphenyls (PCB) 2-8 No NA NA 200
Standard grade. Alternative to silica for viscous matrices due to large particle size.
Pesticides 2-8 No NA NA 200
High purity pesticide grade. Alternative to silica for viscous matrices
Aromatic and naturalproducts; Flavones, Chalkones, Anthraquinones
2-8
No
NA
Hydrophobic peptides and polypeptides Non-polar compounds in aqueous solution
NA
100
Nylon 6
2-8
No
300
-
-
Large pore size for isolation of large biomolecules
2-8
Yes
60
500
50
10% CL; Lower carbon load than C18-S and REC18
Drugs and drug metabolites
2-8
No
60
450
60
Exchange capacity 0.09 meq/g
Drugs and drug metabolites
2-8
No
60
450
60
Exchange capacity 0.10 meq/g
Drugs and drug metabolites
2-8
No
60
450
60
Exchange capacity 0.14 meq/g
Drugs and drug metabolites biological fluids
0-14
No
NA
1500
70
Drugs and drug metabolites biological fluids 0-14 No Wide Pore 1200 90 Mid-polar and non-polar compounds in aqueous and organic solvents
1-13
No
70
800
75
Lipids 0-14 No 70 800 100
High capacity polystyrene-divinylbenzene (PSDVB) High capacity PSDVB for large biomolecules and viscous matrices Mixed hydrophilic/hydrophobic interactions PSDVB; Alternative to high flow silica for mid-polar to non-polar compounds (<3000D) in crude samples
Aqueous environmental compounds that are 1-12 No 70 800 75 not retained on C18
Advanced environmental; Polystyrene-co-2hydroxyethyl methacrylate (PSHEMA)
Mid-polar and non-polar compounds in 0-14 No 80 850 30 & 60 aqueous and organic solvents
Hydrophilic-lipophilic-balanced reversedphase sorbent for acids, bases and neutrals
www.perkinelmer.com/spe
5
PerkinElmer offers a comprehensive selection of SPE products that have been precisely manufactured for guaranteed reproducibility. Not just column to column. Not just batch to batch. But lot to lot — no matter how many days, weeks or years between production times. Supra-Clean and Supra-Poly SPE products are available in a range of media weights, volumes and formats, including easy to order selection kits and application packs.
SUPRA-CLEAN COLUMNS AND 96 WELL PLATES • Pure spherical silica • Pore size 60 - 120 Å • 20 chemistries with pH range 2-8
Supra-Clean C18
Supra-Clean REC18
Columns
Columns
Media Weight
Volume
Part No.
Quantity
Media Weight
Volume
Part No.
Quantity
50 mg
1 ml
N9306476
50
50 mg
1 ml
N9306519
50
100 mg
1 ml
N9306478
100
100 mg
1 ml
N9306520
100
100 mg
3 ml
N9306523
50
100 mg
3 ml
N9306455
50
3 ml
N9306521
50
200 mg
3 ml
N9306462
50
200 mg
500 mg
3 ml
N9306438
50
500 mg
3 ml
N9306522
50
6 ml
N9306633
30
500 mg
3 ml*
N9306642
50
200 mg
200 mg
6 ml
N9306634
30
500 mg
6 ml
N9306457
30
6 ml
N9306491
30
Volume
Part No.
Quantity
500 mg
6 ml
N9306448
30
1g
500 mg
6 ml*
N9306640
30
96 Well Plates
1g
6 ml
N9306422
30
2g
6 ml
N9306430
30
2g
15 ml
N9306479
20
2g
25 ml
N9306475
20
Media Weight
25 mg
2 ml
N9306563
1
50 mg
2 ml
N9306564
1
100 mg
2 ml
N9306565
1
* Not end-capped
Supra-Clean Strong Anion Exchange (SAX)
96 Well Plates Media Weight
Volume
Part No.
Quantity
Columns
25 mg
2 ml
N9306566
1
Media Weight
Volume
Part No.
Quantity
50 mg
2 ml
N9306567
1
50 mg
1 ml
N9306553
50
100 mg
2 ml
N9306568
1
100 mg
1 ml
N9306471
100
100 mg
3 ml
N9306554
50
Supra-Clean C18 Cartridges Media Weight
Volume
Part No.
Quantity
390 mg
--
N9306587
50
910 mg
--
N9306588
50
1690 mg
--
N9306589
50
200 mg
3 ml
N9306482
50
500 mg
3 ml
N9306555
50
500 mg
6 ml
N9306556
30
Volume
Part No.
Quantity
96 Well Plates Media Weight
6
25 mg
2 ml
N9306581
1
50 mg
2 ml
N9306582
1
100 mg
2 ml
N9306583
1
Supra-Clean 300Å C4 96 Well Plates
Columns Media Weight
Volume
Part No.
Quantity
50 mg
1 ml
N9306590
50
100 mg
1 ml
N9306591
100
100 mg
3 ml
N9306592
50
200 mg
3 ml
N9306593
50
Media Weight
Volume
Part No.
Quantity
25 mg
2 ml
N9306578
1
50 mg
2 ml
N9306579
1
100 mg
2 ml
N9306580
1
Supra-Clean Mixed-Mode (MM2) Columns
Supra-Clean Strong Cation Exchange (SCX) Columns Media Weight
Volume
Part No.
Quantity
50 mg
1 ml
N9306536
50
100 mg
1 ml
N9306432
100
100 mg
3 ml
N9306537
50
200 mg
3 ml
N9306538
50
500 mg
3 ml
N9306539
50
500 mg
6 ml
N9306540
30
Media Weight
Volume
Part No.
Quantity
25 mg
2 ml
N9306575
1
50 mg
2 ml
N9306576
1
100 mg
2 ml
N9306577
1
96 Well Plates
Media Weight
Volume
Part No.
Quantity
50 mg
1 ml
N9306548
50
100 mg
1 ml
N9306549
100
100 mg
3 ml
N9306550
50
200 mg
3 ml
N9306551
50
500 mg
3 ml
N9306411
50
500 mg
6 ml
N9306552
30
Supra-Clean Mixed-Mode (MM3) Columns Media Weight
Volume
Part No.
Quantity
500 mg
6 ml
N9306649
30
Supra-Clean Florisil (FL-S) Columns
Supra-Clean Weak Cation Exchange (WCX) Columns Media Weight
Volume
Part No.
Quantity
50 mg
1 ml
N9306544
50
100 mg
1 ml
N9306545
100
100 mg
3 ml
N9306546
50
200 mg
3 ml
N9306547
50
500 mg
3 ml
N9306420
50
500 mg
6 ml
N9306407
30
Media Weight
Volume
Part No.
Quantity
200 mg
3 ml
N9306511
50
500 mg
3 ml
N9306512
50
500 mg
6 ml
N9306494
30
1g
6 ml
N9306413
30
2g
6 ml
N9306513
20
2g
15 ml
N9306514
20
2g
25 ml
N9306515
20
Supra-Clean Florisil (FL-S) Pesticide Grade
Supra-Clean Mixed-Mode (MM1)
Columns
Columns
Media Weight
Volume
Part No.
Quantity
200 mg
3 ml
N9306516
50
50
500 mg
3 ml
N9306400
50
N9306542
100
500 mg
6 ml
N9306517
30
3 ml
N9306419
50
1g
6 ml
N9306436
30
200 mg
3 ml
N9306543
50
2g
6 ml
N9306470
30
500 mg
3 ml
N9306481
50
2g
15 ml
N9306443
20
500 mg
6 ml
N9306416
30
2g
25 ml
N9306447
20
200 mg
15 ml
N9306713
20
Media Weight
Volume
Part No.
Quantity
50 mg
1 ml
N9306541
100 mg
1 ml
100 mg
www.perkinelmer.com/spe
7
Supra-Clean Silica (SI-S)
Supra-Clean Polyamine (P6)
Columns
Columns
Media Weight
Volume
Part No.
Quantity
Media Weight
Volume
Part No.
Quantity
100 mg
3 ml
N9306532
50
500 mg
3 ml
N9306518
50
200 mg
3 ml
N9306444
50
500 mg
6 ml
N9306434
30
500 mg
3 ml
N9306402
50
500 mg
6 ml
N9306466
30
Supra-Clean Phenyl (PH-S)
1g
6 ml
N9306404
30
Columns
2g
6 ml
N9306533
20
2g
15 ml
N9306534
20
2g
25 ml
N9306535
20
Cartridges Media Weight
Volume
Part No.
Quantity
300 mg
--
N9306584
50
Media Weight
Volume
Part No.
Quantity
50 mg
1 ml
N9306401
50
100 mg
1 ml
N9306524
100
100 mg
3 ml
N9306525
50
200 mg
3 ml
N9306490
50
500 mg
3 ml
N9306421
50
6 ml
N9306526
30
6 ml
N9306527
30
700 mg
--
N9306585
50
500 mg
1300 mg
--
N9306586
50
1g 96 Well Plates
Supra-Clean Cyano (CN-S) Columns
Media Weight
Volume
Part No.
Quantity
25 mg
2 ml
N9306569
1
Media Weight
Volume
Part No.
Quantity
50 mg
2 ml
N9306570
1
500 mg
3 ml
N9306645
50
100 mg
2 ml
N9306571
1
500 mg
6 ml
N9306644
30
Supra-Clean LCC Supra-Clean Amino (NH2-S)
Columns
Columns
Media Weight
Volume
Part No.
Quantity
Media Weight
Volume
Part No.
Quantity
500 mg
3 ml
N9306643
50
50 mg
1 ml
N9306528
50
500 mg
6 ml
N9306641
30
100 mg
1 ml
N9306410
100
100 mg
3 ml
N9306529
50
500 mg
3 ml
N9306414
50
200 mg
6 ml
N9306530
50
500 mg
6 ml
N9306531
30
Media Weight
Volume
Part No.
Quantity
96 Well Plates
8
25 mg
2 ml
N9306572
1
50 mg
2 ml
N9306573
1
100 mg
2 ml
N9306574
1
SUPRA-POLY HLB COLUMNS AND 96 WELL PLATES • Contains macro-porous polymers with ultra-pure, pharmaceutical grade spherical particles • Shorter analysis times, greater load capacity and reduced solvent usage • Ideal for high throughput assays
Supra-Poly HLB 30 µm Columns Media Weight
Volume
Part No.
Quantity
30 mg
1 ml
N9306650
50
50 mg
1 ml
N9306655
50
60 mg
1 ml
N9306656
50
100 mg
1 ml
N9306657
50
30 mg
3 ml
N9306651
50
Media Weight
Volume
Part No.
Quantity
200 mg
6 ml*
N9306693
30
500 mg
6 ml
N9306684
30
500 mg
15 ml
N9306685
20
500 mg
6 ml*
N9306694
30
1g
15 ml
N9306686
20
30 mg
15 ml**
N9306688
50
60 mg
15 ml**
N9306689
50
100 mg
15 ml**
N9306690
50
200 mg
15 ml**
N9306691
50
1g
25 ml
N9306687
20
60 mg
3 ml
N9306658
50
100 mg
3 ml
N9306659
50
200 mg
3 ml
N9306660
50
500 mg
3 ml
N9306661
30
100 mg
6 ml*
N9306672
30
150 mg
6 ml
N9306662
30
200 mg
6 ml
N9306663
30
200 mg
6 ml*
N9306673
30
500 mg
6 ml*
N9306674
30
500 mg
6 ml
N9306664
30
500 mg
15 ml
N9306665
20
1g
15 ml
N9306666
20
Media Weight
Volume
30 mg
15 ml**
N9306668
50
30 mg
60 mg
15 ml**
N9306669
50
50 mg
100 mg
15 ml**
N9306670
50
60 mg
200 mg
15 ml**
N9306671
50
1g
25 ml
N9306667
20
Media Weight
Volume
Part No.
Quantity
30 mg
1 ml
N9306652
50
* Glass columns
** LRC columns
30 µm 96 Well Plates Media Weight
Volume
Part No.
Quantity
30 mg
2 ml
N9306698
1
50 mg
2 ml
N9306699
1
60 mg
2 ml
N9306700
1
Part No.
Quantity
2 ml
N9306695
1
2 ml
N9306696
1
2 ml
N9306697
1
60 µm 96 Well Plates
60 µm Columns
50 mg
1 ml
N9306675
50
60 mg
1 ml
N9306676
50
100 mg
1 ml
N9306677
50
30 mg
3 ml
N9306653
50
60 mg
3 ml
N9306678
50
100 mg
3 ml
N9306679
50
200 mg
3 ml
N9306680
50
500 mg
3 ml
N9306681
30
100 mg
6 ml*
N9306692
30
150 mg
6 ml
N9306682
30
200 mg
6 ml
N9306683
30
www.perkinelmer.com/spe
9
SUPRA-POLY COLUMNS AND 96 WELL PLATES • Contains macro-porous polymers with ultra-pure, pharmaceutical grade spherical particles • Shorter analysis times, greater load capacity and reduced solvent usage • Ideal for high throughput assays
Supra-Poly Extreme Capacity 1500 m2/g (XC)
Supra-Poly Environmental (AEV)
Columns
Columns
Media Weight
Volume
Part No.
Quantity
Media Weight
Volume
Part No.
Quantity
30 mg
1 ml
N9306441
50
100 mg
3 ml
N9306648
50
50 mg
1 ml
N9306500
50
60 mg
1 ml
N9306501
50
Supra-Poly Hydrophilic (ATH)
100 mg
1 ml
N9306403
50
Columns
60 mg
3 ml
N9306502
50
100 mg
3 ml
N9306440
50
200 mg
3 ml
N9306428
50
200 mg
6 ml
N9306635
30
500 mg
6 ml
N9306405
30
1g
15 ml
N9306503
20
96 Well Plates
Media Weight
Volume
Part No.
Quantity
100 mg
3 ml
N9306646
50
200 mg
3 ml
N9306638
50
200 mg
6 ml
N9306636
30
Supra-Poly Lipophilic (ATL) Columns
Media Weight
Volume
Part No.
Quantity
30 mg
2 ml
N9306557
1
50 mg
2 ml
N9306558
1
60 mg
2 ml
N9306559
1
Media Weight
Volume
Part No.
Quantity
100 mg
3 ml
N9306647
50
200 mg
3 ml
N9306639
50
200 mg
6 ml
N9306637
30
Supra-Poly Extra Wide Particle 1200 m2/g (XWP) Columns Media Weight
Volume
Part No.
Quantity
30 mg
1 ml
N9306504
50
50 mg
1 ml
N9306427
50
60 mg
1 ml
N9306505
50
100 mg
1 ml
N9306506
50
60 mg
3 ml
N9306507
50
100 mg
3 ml
N9306508
50
200 mg
3 ml
N9306509
50
500 mg
6 ml
N9306418
30
1g
15 ml
N9306510
20
96 Well Plates
10
Media Weight
Volume
Part No.
Quantity
30 mg
2 ml
N9306560
1
50 mg
2 ml
N9306561
1
60 mg
2 ml
N9306562
1
Compared to other industry leading SPE materials, our Extreme Capacity (XC) and Extra Wide Particles (XWP) lead market in surface area. This allows for higher capacities at lower bed weights.
SPE SELECTION KITS: Enables quick column selection for development of reproducible and repeatable SPE methods. Description
Media Weight
Volume
Part No.
Quantity
Pre-Concentration of Hydrophobic Compounds from Aqueous Matrix
200 mg 200 mg
6 ml 3 ml
N9306594 N9306595
50 50
Extraction of Hydrophobic Compounds from Aqueous Matrix
500 mg 500 mg
6 ml 3 ml
N9306596 N9306597
50 50
Pre-Concentration of Hydrophilic Compounds
500 mg 500 mg
6 ml 3 ml
N9306598 N9306599
30 30
Removal of Polar Compounds from Aqueous and Organic Matrix
500 mg 500 mg
6 ml 3 ml
N9306600 N9306601
30 30
Extraction of Acidic Basic and Neutral Compounds from Aqueous or Organic Matrix
100 mg
3 ml
N9306602
50
Extraction of Carboxylic Acids and Strong Bases from Aqueous Matrix
500 mg
6 ml
N9306603
40
Extraction of Weak Bases from Aqueous Matrix
500 mg
6 ml
N9306604
30
SPE APPLICATION PACKS: Ideal for extraction of known entities from a variety of matrices, our packs are expertly tailored to meet your application needs and are designed to support major EPA methods and applications. Description
Media Weight
Volume
Part No.
Quantity
Extraction of Basic Drugs from Biological Fluids
200 mg
3 ml
N9306605
50
Extraction of Bisphenol A from Aqueous Matrix
1g
6 ml
N9306613
30
500 mg 1g
3 ml 6 ml
N9306612 N9306611
50 30
Extraction of PAH from Soil and Oil
1.5 g
6 ml
N9306609
30
Extraction of PAH from Soil and Oil (Glass Straight Column)
1.5 g
6 ml
N9306610
30
Extraction of PAH from Water Containing Humic Acids
1.5 g
6 ml
N9306608
30
Extraction of PAH from Water or Soil
4g
6 ml
N9306606
30
Extraction of PAH from Water or Soil (Glass Straight Column)
4g
6 ml
N9306607
30
Extraction of PCB from Oil
1g 1g
6 ml 3 ml
N9306617 N9306616
30 50
Extraction of Pesticides and Herbicides from Aqueous Matrix
500 mg
3 ml
N9306614
50
Extraction of Steroids from Biological Fluids
500 mg
6 ml
N9306615
30
1g
6 ml
N9306618
30
Extraction of Oil and Grease from Aqueous Matrix-EPA 1664
Extraction of SVOC from Water-EPA 525
SPE VACUUM PUMPS, MANIFOLDS AND ACCESSORIES: SPE Vacuum Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15, and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction process and the sample flow. Waste and wash solvents are discarded and analytes are collected in sample tubes below the manifold completing the extraction. Description
12 Position Part No.
Quantity
24 Position Part No.
Quantity
Vacuum Manifold
N9306619
1 each
N9306626
1 each
Replacement Chamber (Glass)
N9306620
1 each
N9306627
1 each
Cover Gasket - 12 Position
N9306621
1 each
N9306628
1 each
Stopcocks - 12 Position
N9306624
12 pack
N9306631
24 pack
Needles - Polypropylene
N9306622
12 pack
N9306629
24 pack
Needles - Stainless Steel
N9306623
12 pack
N9306630
24 pack
Drying Attachment
N9306625
1 each
N9306632
1 each
Description
Vacuum Pumps
www.perkinelmer.com/spe
20 L/min 115V
60 L/min 115V
17 L/min 230V
58 L/min 230V
Quantity
N9308035
N9308063
N9308331
N9308332
1 each
11
At PerkinElmer, we understand that sample preparation is one of the most critical steps in the analytical process. Often accounting for 60% or more of your timetable, it has a fundamental impact on a wide range of operational parameters. Any errors within this process undermine the quality of your data at all subsequent stages of your analysis. Solid Phase Extraction helps avoid potential errors in sample preparation, reducing re-runs and dramatically increasing productivity. As one of the most cost-effective and flexible tools within the laboratory environment, SPE also provides efficient sample concentration and purification prior to many of today’s most popular analytical techniques, including HPLC, LC/MS, GC and GC/MS.
The right accessories, consumables, methods and application support are as integral to the success of your laboratory as your instrumentation. That’s why we invest heavily in testing and validating our complete portfolio of solutions to ensure you receive accurate, repeatable results on time, every time.
SPE columns are part of PerkinElmer’s complete offering of analytical solutions—an industry-leading portfolio that encompasses instruments, accessories, consumables, supplies, training and service. It’s a breadth of capabilities that enables us to offer the ease and convenience of having a single supplier for all your needs at every stage of your workflow. So you can benefit from greater responsiveness, superior reliability, and dramatic cost savings.
Couple SPE With Leading Instrumentation For Ultimate Laboratory Efficiency Clarus® 680/580/480 GC Clarus SQ 8 GC/MS Flexar™ SQ 300 MS Flexar LC and UHPLC
PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com
Our OneSource Laboratory Services division even takes it a step further. With more than 1,500 trained and certified field service engineers and service personnel around the world, OneSource offers the most comprehensive portfolio of professional laboratory services in the industry, including complete care programs for virtually every technology and manufacturer. So turn to PerkinElmer. For the experience. For the confidence. For the better.