Mobile Networks
1
Jumper cable
Feeder cable + connector
Cable clamp
Grounding kit
2
Contents
Antenna Line Products and Contents Draka - Your Reliable Partner Mobile Network Products Feeder Cables RFA 1/4” RFA 3/8” RFA 1/2” RFA 7/8” RFA 7/8” AL RFA 1 1/4” RFA 1 5/8” RFA 1 5/8” AL RFA 2 1/4” Superflexible and Extraflexible Cables RFF 1/4” RFF 3/8” RFF 1/2” RFE 7/8” RFE 1 1/4” RFE 1 5/8” Coaxial Antennas RFX 1/2” RFX 7/8” RFX 1 1/4” RFX 1 5/8” RFXT 7/8” RFXT 1 1/4” Jumpers Accessories Drums Environment and Quality How to contact us All information in this catalog is subject to change without prior notice.
2-3 4-5 6-7 8-9 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-41 42-43 44-45 46-47 48-49 50-51 52-53 54-55 56-57 58-59 60-61 62-65 66-67
3
Draka – Your Reliable Partner
4
Draka is one of the leading cable manufacturers in the world today. Draka companies are engaged in the development, production and sales of cables and cable systems worldwide. Based on our long experience and expertise in cable manufacturing, we are today one of the most reliable cable suppliers. We are committed to offering our customers a technically advanced product portfolio and competent service. An essential part of our philosophy is to implement constant improvements and to develop new products and services to provide value for our customers on a sustainable basis. Draka is a guarantee of outstanding performance in all relevant circumstances. You will find more information about Draka at www.draka.com.
5
Mobile Network Cable Products
6
Draka offers a wide range of products with guaranteed compatibility and reliability for mobile networks. In this catalogue you will find Mobile Network Cable products: feeder cables, coaxial antennas, superflexible cables and jumpers. Accessories are presented at the end of the catalogue. Our production facilities located in Finland and China are equipped with modern production lines, and we can provide products from leading connector and accessory manufacturers through our extensive partner network. To ensure prompt deliveries, we have established our own distribution centers in different parts of the world. Flexible customer service is one of our strengths and our extensive resale network serves our customers locally worldwide. Draka feeder cables, flexible cables and coaxial antennas have outstanding performance in mobile telecommunication applications, such as GSM, WCDMA (UMTS), TDMA, D-AMPS, PCN, CDMA and TETRA. They are also used in some other applications e.g. WiMAX and broadcasting. Our cables have been designed to transmit signal power between the transmission equipment and the antenna even in most demanding environmental conditions and thus meet the highest technical and environmental standards. All of our cables are halogen free and non corrosive. They are available in standard polyethylene jacket and in fire retardant, low smoke emission jacket in black (BHF) or grey (GHF). Our cables and jumpers comply with the European Union RoHS directive (Restriction of Hazardous Substances).
7
8
Feeder Cables Our feeder cable family, RFA, has been designed to meet the highest technical standards. Enhanced electrical values, uniform impedance and low attenuation at high frequencies make RFA an optimal choice for all applications including UMTS and WiMAX. Our RFA cables are compatible with standard connectors and accessories. RFA cables’ unique two layer jacketing with harder HDPE surface and softer LDPE inside gives the cable best protection in all installation environments without losing flexibility. In our cables, the foam dielectric has an extremely high degree of expansion and a special skin layer for extra protection.
Draka 50 Ohm Radio Frequency Cables FEEDER CABLES Type
Product code
Inner conductor diam. mm (in)
Outer conductor diam. mm (in)
Jacket diam.
Standard length
mm (in)
m (ft)
Standard drum type
RFA 1/4”-50
NKRFA01400
2.4 (0.09)
7.5 (0.3)
10.0 (0.39)
500 (1640)
P6D
RFA 3/8”-50
NKRFA03800
3.1 (0.12)
9.5 (0.37)
11.2 (0.44)
250 (820)
P6D
RFA 1/2”-50
NKRFA01200
4.8 (0.19)
13.9 (0.55)
16.0 (0.63)
500 (1640)
P11D
RFA 7/8”-50
NKRFA07800
9.4 (0.37)
25.4 (1.00)
27.8 (1.09)
500 (1640)
P13G
RFA 7/8”-50 AL
NKRFAL07800
9.4 (0.37)
25.4 (1.00)
28.0 (1.10)
500 (1640)
P13G
RFA 1 1/4”-50
NKRFA11400
13.0 (0.51)
35.8 (1.41)
39.0 (1.54)
600 (1968)
P20G
RFA 1 5/8”-50
NKRFA15800
17.6 (0.69)
46.3 (1.82)
50.0 (1.97)
400 (1312)
P20G
RFA 1 5/8”-50 AL
NKRFAL15800
17.5 (0.69)
46.5 (1.83)
50.0 (1.97)
400 (1312)
P20G
RFA 2 1/4”-50
NKRFA21400
21.2 (0.83)
55.9 (2.20)
60.0 (2.36)
300 (984)
P21Q
9
Feeder cable
RFA 1/4”-50
Specifications
COAXIAL CABLE Type
Code
RFA 1/4”-50
NKRFA01400
RFA 1/4”-50 GHF
NKRFA01401
RFA 1/4”-50 BHF
NKRFA01402
RFA 1/4”-50 BHF (UL) CATVR
NKRFA01404
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 2.4 mm Ø 6.0 mm Ø 7.5 mm Ø 10.0 mm
(0.09 in) (0.24 in) (0.3 in) (0.39 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.83 80 pF/m (24 pF/ft) 16 000 MHz See table 1.04 kV 11.6 kW
DC-resistance • Inner conductor • Outer conductor
5.55 Ω/km (1.69 Ω/1000ft) 4.11 Ω/km (1.25 Ω/1000ft)
10
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFA 1/4”-50
Black, halogen free polyethylene
yes
no
no
yes
no
-40°C (-40°F)
RFA 1/4”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFA 1/4”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFA 1/4”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Feeder cable RFA 1/4”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 8000 10000 12000 16000
1.31 2.28 2.95 3.93 4.19 4.36 5.16 5.56 5.98 7.36 8.54 9.08 9.59 9.71 10.5 11.4 12.3 12.7 13.0 13.0 13.4 13.5 13.8 15.2 16.5 17.7 18.8 19.4 19.9 21.0 22.0 23.0 23.9 24.9 26.6 36.5 43.0 48.9 54.3 64.4
(0.399) (0.694) (0.899) (1.20) (1.28) (1.33) (1.57) (1.70) (1.82) (2.24) (2.60) (2.77) (2.92) (2.96) (3.21) (3.48) (3.74) (3.86) (3.95) (3.98) (4.09) (4.11) (4.20) (4.63) (5.02) (5.39) (5.75) (5.91) (6.08) (6.40) (6.71) (7.01) (7.30) (7.58) (8.11) (11.1) (13.1) (14.9) (16.6) (19.6)
5.5 3.2 2.5 1.8 1.7 1.7 1.4 1.3 1.2 1.0 0.85 0.80 0.75 0.74 0.69 0.63 0.59 0.57 0.56 0.55 0.54 0.54 0.52 0.48 0.44 0.41 0.38 0.37 0.36 0.34 0.33 0.32 0.30 0.29 0.27 0.20 0.17 0.15 0.14 0.11
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.12 kg/m 790 N
(0.08 lb/ft) (177 lb)
40 mm (1.6 in) 100 mm (3.9 in) -55...+80°C (-67...+176°F) 1.9 kg/mm (106 lb/in) 1.8 Nm (1.3 lb-ft) 0.6 m (2 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 1/4”
P6D
(ft)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
500 (1640) 63 (25) 51 (20)
Drum weight (empty) kg (lb) 13 (29)
Total weight kg (lb) 83 (116)
Drum freight volume m3 (cu.ft) 0.20 (7.06)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1014100
N male
NKC1014300
N female
NKC1014400
N male Right angle
NKC1014600
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
11
Feeder cable
RFA 3/8”-50
Specifications
COAXIAL CABLE Type
Code
RFA 3/8”-50
NKRFA03800
RFA 3/8”-50 GHF
NKRFA03801
RFA 3/8”-50 BHF
NKRFA03802
RFA 3/8”-50 BHF (UL) CATVR
NKRFA03804
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 3.1 mm (0.12 in) Ø 8.0 mm (0.32 in) Ø 9.5 mm (0.37 in) Ø 11.2 mm (0.44 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.86 78 pF/m (24 pF/ft) 14 000 MHz See table 1.2 kV 16.1 kW
DC-resistance • Inner conductor • Outer conductor
3.6 Ω/km (1.10 Ω/1000ft) 3.1 Ω/km (0.94 Ω/1000ft)
12
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFA 3/8”-50
Black, halogen free polyethylene
yes
no
no
yes
no
-40°C (-40°F)
RFA 3/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFA 3/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFA 3/8”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Feeder cable RFA 3/8”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 13500
1.02 1.78 2.31 3.08 3.29 3.42 4.37 4.70 5.79 6.73 7.16 7.57 7.67 8.34 9.04 9.71 10.0 10.3 10.3 10.6 10.7 10.9 12.1 13.1 14.1 15.0 15.5 15.9 16.8 17.6 18.4 19.2 20.0 21.4 29.6 48.1
(0.31) (0.54) (0.70) (0.94) (1.00) (1.04) (1.33) (1.43) (1.77) (2.05) (2.18) (2.31) (2.34) (2.54) (2.76) (2.96) (3.06) (3.13) (3.15) (3.24) (3.26) (3.34) (3.68) (4.00) (4.30) (4.59) (4.72) (4.86) (5.12) (5.37) (5.62) (5.86) (6.09) (6.53) (9.04) (14.7)
6.8 3.9 3.0 2.2 2.1 2.0 1.6 1.5 1.2 1.0 0.97 0.92 0.90 0.83 0.77 0.71 0.69 0.67 0.67 0.65 0.65 0.63 0.57 0.53 0.49 0.46 0.45 0.43 0.41 0.39 0.38 0.36 0.35 0.32 0.24 0.15
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.13 kg/m 1650 N
(0.08 lb/ft) (363 lb)
50 mm 95 mm -55...+80°C 2.0 kg/mm 2.1 Nm 1.0 m
(1.9 in) (3.7 in) (-67...+176°F) (110 lb/in) (1.5 lb-ft) (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length
Outer diam. (D) cm (in)
Outer width (W) cm (in)
Drum weight (empty) kg (lb)
250 (820) 63 (25)
51 (20)
13 (29)
m RFA 3/8”
P6D
(ft)
Total weight kg (lb) 55 (117)
Drum freight volume m3 (cu.ft) 0.20 (7.06)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1038100
7-16 female
NKC1038200
N male
NKC1038300
N female
NKC1038400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
13
Feeder cable
RFA 1/2”-50
Specifications
COAXIAL CABLE Type
Code
RFA 1/2”-50
NKRFA01200
RFA 1/2”-50 GHF
NKRFA01201
RFA 1/2”-50 BHF
NKRFA01202
RFA 1/2”-50 BHF (UL) CATVR
NKRFA01204
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 4.8 mm (0.19 in) Ø 12.1 mm (0.48 in) Ø 13.9 mm (0.55 in) Ø 16.0 mm (0.63 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz • 3400–3600 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.88 76 pF/m (23pF/ft) 9800 MHz See table 1.80 kV 31.8 kW
DC-resistance • Inner conductor • Outer conductor
1.44 Ω/km (0.44 Ω /1000ft) 2.24 Ω/km (0.68 Ω /1000ft)
14
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFA 1/2”-50
Black, halogen free polyethylene
yes
no
no
yes
no
-40°C (-40°F)
RFA 1/2”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFA 1/2”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFA 1/2”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Feeder cable RFA 1/2”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 8800
0.665 1.16 1.51 2.01 2.15 2.24 2.86 3.08 3.81 4.43 4.72 4.99 5.06 5.50 5.98 6.43 6.64 6.81 6.85 7.06 7.10 7.26 8.02 8.74 9.41 10.0 10.4 10.7 11.3 11.8 12.4 12.9 13.4 14.4 20.2 25.5
(0.203) (0.354) (0.459) (0.613) (0.655) (0.682) (0.873) (0.938) (1.16) (1.35) (1.44) (1.52) (1.54) (1.68) (1.82) (1.96) (2.03) (2.08) (2.09) (2.15) (2.16) (2.21) (2.45) (2.66) (2.87) (3.06) (3.16) (3.25) (3.43) (3.60) (3.77) (3.94) (4.09) (4.40) (6.15) (7.77)
12 6.9 5.3 4.0 3.7 3.6 2.8 2.6 2.1 1.8 1.7 1.6 1.6 1.4 1.3 1.2 1.2 1.2 1.2 1.1 1.1 1.1 0.98 0.90 0.83 0.78 0.76 0.74 0.70 0.66 0.63 0.61 0.58 0.54 0.39 0.31
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.23 kg/m 2550 N
(0.15 lb/ft) (562 lb)
70 mm 120 mm -55...+80°C 2.0 kg/mm 3.8 Nm 1.0 m
(2.8 in) (4.7 in) (-67...+176°F) (110 lb/in) (2.8 lb-ft) (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 1/2”
P11D
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
Drum weight (empty) kg (lb)
114 (45)
51 (20)
45 (99)
Total weight kg
(lb)
176 (379)
Drum freight volume m3 (cu.ft) 0.66 (23.31)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1012100
7-16 female
NKC1012200
N male
NKC1012300
N female
NKC1012400
7-16 male Right angle
NKC1012500
N male Right angle
NKC1012600
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
15
Feeder cable
RFA 7/8”-50
Specifications
COAXIAL CABLE Type
Code
RFA 7/8”-50
NKRFA07800
RFA 7/8”-50 GHF
NKRFA07801
RFA 7/8”-50 BHF
NKRFA07802
RFA 7/8”-50 BHF (UL) CATVR
NKRFA07804
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper tube Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 9.4 mm Ø 22.5 mm Ø 25.4 mm Ø 28.0 mm
(0.37 in) (0.89 in) (1.00 in) (1.10 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz • 3400–3600 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.90 74.2 pF/m (22.6 pF/ft) 5100 MHz See table 3.3 kV 92.0 kW
DC-resistance • Inner conductor • Outer conductor
1.28 Ω/km (0.39 Ω/1000 ft) 1.15 Ω/km (0.35 Ω/1000 ft)
16
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFA 7/8”-50
Black, halogen free polyethylene (LDPE with HDPE skin)
yes
no
no
yes
no
-40°C (-40°F)
RFA 7/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFA 7/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFA 7/8”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Feeder cable RFA 7/8”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 3500 3600 4000 5000
0.346 0.603 0.782 1.04 1.12 1.16 1.48 1.60 1.97 2.29 2.44 2.58 2.61 2.84 3.09 3.32 3.43 3.52 3.54 3.64 3.66 3.74 4.14 4.50 4.84 5.17 5.33 5.48 5.78 6.07 6.35 6.63 6.89 7.40 7.53 7.65 8.13 9.26
(0.105) (0.184) (0.238) (0.318) (0.340) (0.354) (0.452) (0.486) (0.601) (0.699) (0.744) (0.787) (0.797) (0.867) (0.942) (1.01) (1.05) (1.07) (1.08) (1.11) (1.12) (1.14) (1.26) (1.37) (1.48) (1.58) (1.62) (1.67) (1.76) (1.85) (1.94) (2.02) (2.10) (2.26) (2.29) (2.33) (2.48) (2.82)
27 16 12 8.9 8.4 8.0 6.3 5.8 4.7 4.0 3.8 3.6 3.5 3.2 3.0 2.8 2.7 2.6 2.6 2.5 2.5 2.5 2.2 2.0 1.9 1.8 1.7 1.7 1.6 1.5 1.4 1.4 1.3 1.2 1.2 1.2 1.1 0.97
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.45 kg/m 2500 N
(0.30 lb/ft) (562 lb)
120 mm (4.7 in) 240 mm (9.4 in) -55...+85°C (-67...+185°F) 1.6 kg/mm (90 lb/in) 15.0 Nm (11 lb-ft) 1.0 m (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 7/8”
P13G
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
134 (52)
70 (28)
Drum weight (empty) kg (lb) 69 (152)
Total weight kg
(lb)
Drum freight volume m3 (cu.ft)
343 (760) 1.26 (44.50)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1078100
7-16 female
NKC1078200
7-16 Bulkhead female
NKC1078290
N male
NKC1078300
N female
NKC1078400
7-16 male Right angle
NKC1078500
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
17
Feeder cable
RFA 7/8”-50 AL
Specifications
COAXIAL CABLE Type
Code
RFA 7/8”-50 AL
NKRFAL07800
RFA 7/8”-50 AL GHF
NKRFAL07801
RFA 7/8”-50 AL BHF
NKRFAL07802
RFA 7/8”-50 AL BHF (UL) CATVR
NKRFAL07804
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper tube Cellular polyethylene Corrugated aluminium tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 9.4 mm Ø 22.4 mm Ø 25.4 mm Ø 28.0 mm
(0.37 in) (0.88 in) (1.00 in) (1.10 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz • 3400–3600 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.90 73.5 pF/m (22.4 pF/ft) 5100 MHz See table 3.2 kV 91.0 kW
DC-resistance • Inner conductor • Outer conductor
1.30 Ω/km (0.40 Ω/1000 ft) 1.26 Ω/km (0.38 Ω/1000 ft)
18
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFA 7/8”-50 AL
Black, halogen free polyethylene (LDPE with HDPE skin)
yes
no
no
yes
no
-40°C (-40°F)
RFA 7/8”-50 AL GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFA 7/8”-50 AL BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFA 7/8”-50 AL BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Feeder cable RFA 7/8”-50 AL
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 3500 3600 4000 5000
0.380 0.662 0.859 1.15 1.23 1.27 1.63 1.75 2.17 2.52 2.68 2.84 2.87 3.13 3.40 3.65 3.77 3.87 3.89 4.01 4.03 4.12 4.55 4.95 5.33 5.69 5.86 6.03 6.36 6.68 6.99 7.29 7.59 8.15 8.29 8.42 8.95 10.2
(0.116) (0.202) (0.262) (0.350) (0.373) (0.388) (0.497) (0.534) (0.660) (0.768) (0.818) (0.865) (0.876) (0.953) (1.04) (1.11) (1.15) (1.18) (1.19) (1.22) (1.23) (1.26) (1.39) (1.51) (1.62) (1.73) (1.79) (1.84) (1.94) (2.04) (2.13) (2.22) (2.31) (2.48) (2.53) (2.57) (2.73) (3.11)
26 15 11 8.6 8.1 7.7 6.1 5.6 4.5 3.9 3.7 3.5 3.4 3.1 2.9 2.7 2.6 2.5 2.5 2.4 2.4 2.4 2.1 2.0 1.8 1.7 1.7 1.6 1.5 1.5 1.4 1.3 1.3 1.2 1.2 1.2 1.1 0.9
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.37 kg/m 1500 N
(0.25 lb/ft) (331 lb)
120 mm (4.7 in) 240 mm (9.4 in) -55...+80°C (-67...+176°F) 1.1 kg/mm (62 lb/in) 18.0 Nm (13 lb-ft) 1.0 m (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 7/8” AL
P13G
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
134 (52)
70 (28)
Drum weight (empty) kg (lb) 69 (152)
Total weight kg
(lb)
Drum freight volume m3 (cu.ft)
285 (630) 1.26 (44.50)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1078100
7-16 female
NKC1078200
N male
NKC1078300
N female
NKC1078400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
19
Feeder cable
RFA 1 1/4”-50
Specifications
COAXIAL CABLE Type
Code
RFA 1 1/4”-50
NKRFA11400
RFA 1 1/4”-50 GHF
NKRFA11401
RFA 1 1/4”-50 BHF
NKRFA11402
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper tube Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 13.0 mm Ø 32.2 mm Ø 35.8 mm Ø 39.0 mm
(0.51 in) (1.27 in) (1.41 in) (1.54 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance
50 ± 1 Ω
Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.88 75 pF/m (23 pF/ft) 3500 MHz See table 4.6 kV 211.2 kW
DC-resistance • Inner conductor • Outer conductor
0.74 Ω/km 0.65 Ω/km
(0.22 Ω/1000 ft) (0.22 Ω/1000 ft)
20
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFA 1 1/4”-50
Black, halogen free polyethylene (LDPE with HDPE skin)
yes
no
no
yes
-40°C (-40°F)
RFA 1 1/4”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
-5°C (+23°F)
RFA 1 1/4”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
-5°C (+23°F)
Feeder cable RFA 1 1/4”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3300
0.250 0.439 0.571 0.766 0.819 0.853 1.10 1.18 1.47 1.72 1.83 1.94 1.97 2.15 2.34 2.53 2.62 2.68 2.70 2.79 2.80 2.87 3.18 3.48 3.76 4.03 4.17 4.29 4.54 4.79 5.03 5.26 5.48 5.81
(0.076) (0.134) (0.174) (0.234) (0.250) (0.260) (0.335) (0.360) (0.448) (0.524) (0.559) (0.593) (0.600) (0.656) (0.714) (0.770) (0.797) (0.818) (0.823) (0.849) (0.854) (0.874) (0.970) (1.06) (1.15) (1.23) (1.27) (1.31) (1.39) (1.46) (1.53) (1.60) (1.67) (1.77)
41 23 18 13 12 12 9.2 8.6 6.8 5.8 5.5 5.2 5.1 4.7 4.3 3.9 3.8 3.7 3.7 3.6 3.6 3.5 3.1 2.9 2.6 2.5 2.4 2.3 2.2 2.1 1.0 1.9 1.8 1.7
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.89 kg/m 6050 N
(0.60 lb/ft) (1340 lb)
200 mm (8 in) 350 mm (14 in) -55...+80°C (-67...+176°F) 2.6 kg/mm (146 lb/in) 48.7 Nm (35.9 lb-ft) 1.5 m (5 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 1 1/4”
P20G
(ft)
600 (1968)
Outer diam. (D) cm (in) 204 (80)
Outer width (W) cm (in) 70 (28)
Drum weight (empty) kg (lb)
Total weight
155 (342)
735 (1621) 3.08 (108.76)
kg
(lb)
Drum freight volume m3 (cu.ft)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1114100
7-16 female
NKC1114200
7-16 Bulkhead female
NKC1114290
N male
NKC1114300
N female
NKC1114400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
21
Feeder cable
RFA 1 5/8”-50
Specifications
COAXIAL CABLE Type
Code
RFA 1 5/8”-50
NKRFA15800
RFA 1 5/8”-50 GHF
NKRFA15801
RFA 1 5/8”-50 BHF
NKRFA15802
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Corrugated copper tube Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 17.6 mm Ø 42.0 mm Ø 46.3 mm Ø 50.0 mm
(0.69 in) (1.65 in) (1.82 in) (1.97 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.89 74 pF/m (22.6 pF/ft) 2800 MHz See table 5.7 kV 314 kW
DC-resistance • Inner conductor • Outer conductor
1.16 Ω/km (0.35 Ω/1000 ft) 0.43 Ω/km (0.13 Ω/1000 ft)
22
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFA 1 5/8”-50
Black, halogen free polyethylene (LDPE with HDPE skin)
yes
no
no
yes
-20°C (-4°F)
RFA 1 5/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
-5°C (+23°F)
RFA 1 5/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
-5°C (+23°F)
Feeder cable RFA 1 5/8”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800
0.196 0.343 0.447 0.601 0.643 0.669 0.863 0.929 1.16 1.36 1.45 1.54 1.56 1.70 1.85 2.00 2.07 2.13 2.14 2.21 2.22 2.27 2.53 2.77 2.99 3.21 3.32 3.42 3.63 3.82 4.02 4.20
(0.060) (0.105) (0.136) (0.183) (0.196) (0.204) (0.263) (0.283) (0.353) (0.413) (0.441) (0.468) (0.474) (0.518) (0.565) (0.610) (0.631) (0.648) (0.652) (0.673) (0.677) (0.693) (0.770) (0.843) (0.913) (0.979) (1.01) (1.04) (1.11) (1.17) (1.22) (1.28)
55 31 24 18 17 16 12 11 9.1 7.8 7.3 6.9 6.8 6.2 5.7 5.3 5.1 5.0 4.9 4.8 4.7 4.6 4.2 3.8 3.5 3.3 3.2 3.1 2.9 2.7 2.6 2.5
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
1.16 kg/m 3900 N
(0.78 lb/ft) (860 lb)
200 mm (7.9 in) 400 mm (15.7 in) -55...+80°C (-67...+176°F) 3.1 kg/mm (173 lb/in) 45 Nm (33) 1.5 m (5 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 1 5/8”
P20G
(ft)
400 (1312)
Outer diam. (D) cm (in) 204 (80)
Outer width (W) cm (in) 70 (28)
Drum weight (empty) kg (lb)
Total weight
155 (342)
667 (1471) 3.08 (108.76)
kg
(lb)
Drum freight volume m3 (cu.ft)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1158100
7-16 female
NKC1158200
7-16 Bulkhead female
NKC1158290
N male
NKC1158300
N female
NKC1158400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
23
Feeder cable
RFA 1 5/8”-50 AL
Specifications
COAXIAL CABLE Type
Code
RFA 1 5/8”-50 AL
NKRFAL15800
RFA 1 5/8”-50 AL GHF
NKRFAL15801
RFA 1 5/8”-50 AL BHF
NKRFAL15802
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Corrugated copper tube Cellular polyethylene Corrugated aluminium tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 17.5 mm Ø 42.0 mm Ø 46.5 mm Ø 50.0 mm
(0.69 in) (1.65 in) (1.83 in) (1.97 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.89 74 pF/m (22.6 pF/ft) 2800 MHz See table 5.6 kV 310 kW
DC-resistance • Inner conductor • Outer conductor
1.2 Ω/km 0.6 Ω/km
(0.37 Ω/1000 ft) (0.18 Ω/1000 ft)
24
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFA 1 5/8”-50 AL
Black, halogen free polyethylene (LDPE with HDPE skin)
yes
no
no
yes
-40°C (-40°F)
RFA 1 5/8”-50 AL GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
-5°C (+23°F)
RFA 1 5/8”-50 AL BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
-5°C (+23°F)
Feeder cable RFA 1 5/8”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800
0.212 0.372 0.485 0.65 0.70 0.73 0.93 1.01 1.25 1.47 1.56 1.66 1.68 1.84 2.00 2.16 2.23 2.29 2.31 2.38 2.39 2.45 2.72 2.98 3.22 3.46 3.57 3.68 3.90 4.11 4.31 4.51
(0.065) (0.113) (0.148) (0.20) (0.21) (0.22) (0.29) (0.31) (0.38) (0.45) (0.48) (0.51) (0.51) (0.56) (0.61) (0.66) (0.68) (0.70) (0.70) (0.73) (0.73) (0.75) (0.83) (0.91) (0.98) (1.05) (1.09) (1.12) (1.19) (1.25) (1.31) (1.37)
47 27 20.5 15.3 14.3 13.7 10.6 9.8 7.8 6.7 6.2 5.9 5.8 5.3 4.8 4.5 4.3 4.2 4.2 4.0 4.0 3.9 3.5 3.2 2.9 2.7 2.7 2.6 2.4 2.3 2.2 2.1
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.87 kg/m 2000 N
(0.58 lb/ft) (449 lb)
200 mm (7.9 in) 380 mm (15 in) -55...+80°C (-67...+176°F) 1.8 kg/mm (101 lb/in) 49.0 Nm (11.2 lb-ft) 1.5 m (4.9 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 1 5/8” AL P20G
(ft)
400 (1312)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
204 (80)
70 (28)
Drum weight (empty) kg (lb)
Total weight
155 (342)
667 (1471) 3.08 (108.76)
kg
(lb)
Drum freight volume m3 (cu.ft)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1158100
7-16 female
NKC1158200
N male
NKC1158300
N female
NKC1158400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
25
Feeder cable
RFA 2 1/4”-50
Specifications
COAXIAL CABLE Type
Code
RFA 2 1/4”-50
NKRFA21400
RFA 2 1/4”-50 GHF
NKRFA21401
RFA 2 1/4”-50 BHF
NKRFA21402
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Corrugated copper tube Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 21.2 mm Ø 52.0 mm Ø 55.9 mm Ø 60.0 mm
(0.83 in) (2.05 in) (2.20 in) (2.36 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.88 75 pF/m (23 pF/ft) 2300 MHz See table 6.6 kV 449.4 kW
DC-resistance • Inner conductor • Outer conductor
0.55 Ω/km (0.17 Ω /1000 ft) 0.25 Ω/km (0.08 Ω /1000 ft)
26
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFA 2 1/4”-50
Black, halogen free polyethylene
yes
no
no
yes
-20°C (-4°F)
RFA 2 1/4”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
-5°C (23°F)
RFA 2 1/4”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
-5°C (23°F)
Feeder cable RFA 2 1/4”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200
0.167 0.294 0.385 0.521 0.558 0.582 0.755 0.816 1.02 1.21 1.29 1.37 1.39 1.53 1.68 1.82 1.88 1.94 1.95 2.01 2.03 2.08 2.32 2.56 2.78 3.00 3.10 3.21 3.41
(0.051) (0.090) (0.117) (0.159) (0.170) (0.177) (0.230) (0.249) (0.312) (0.368) (0.394) (0.419) (0.425) (0.466) (0.511) (0.553) (0.574) (0.590) (0.594) (0.614) (0.618) (0.633) (0.708) (0.779) (0.848) (0.913) (0.945) (0.977) (1.04)
72 41 31 23 21 21 16 15 12 9.9 9.2 8.7 8.5 7.8 7.1 6.6 6.3 6.2 6.1 5.9 5.9 5.7 5.1 4.7 4.3 4.0 3.8 3.7 3.5
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
1.93 kg/m 6950 N
(1.30 lb/ft) (1550 lb)
240 mm (9.4 in) 500 mm (19.7 in) -55...+80°C (-67...+176°F) 3.5 kg/mm (196 lb/in) 94.5 Nm (70 lb-ft) 1.5 m (5 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFA 2 1/4”
P21Q
(ft)
300 (984)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
214 (84)
105 (41)
Drum weight (empty) kg (lb)
Total weight
218 (481)
884 (1952) 5.40 (190.68)
kg
(lb)
Drum freight volume m3 (cu.ft)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1214100
7-16 female
NKC1214200
N male
NKC1214300
N female
NKC1214400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
27
28
Superflexible and Extraflexible Cables Draka superflexible RFF cables and extraflexible RFE cables offer the most convenient solution for installations in places where limited space requires small bending radius. Our superflexible RFF cables are typically used as jumper cables. They have extremely high flexibility and crush resistance due to deep spiral corrugation. Our extraflexible RFE cables are perfect for applications where low attenuation must be combined with limited space installations. High flexibility and low attenuation of our superflexible and extraflexible cables guarantee top performance in all circumstances.
Draka 50 Ohm Radio Frequency Cables SUPERFLEXIBLE CABLES Type
Product code
Inner conductor diam. mm (in)
Outer conductor diam. mm (in)
Jacket diam.
Standard length
mm (in)
m (ft)
Standard drum type
RFF 1/4”-50
NKRFF01400
1.9 (0.07)
6.4 (0.25)
7.4 (0.29)
250 (820)
P5C
RFF 3/8”-50
NKRFF03800
2.6 (0.10)
9.0 (0.35)
10.1 (0.40)
250 (820)
P5C
RFF 1/2”-50
NKRFF01200
3.55 (0.14)
11.9 (0.47)
13.5 (0.53)
500 (1640)
P11D
RFE 7/8”-50
NKRFE07800
9.4 (0.37)
24.9 (0.98)
27.5 (1.08)
500 (1640)
P13G
RFE 1 1/4”-50
NKRFE11400
13.6 (0.53)
35.8 (1.41)
39.0 (1.53)
600 (1968)
P20G
RFE 1 5/8”-50
NKRFE15800
17.5 (0.69)
46.5 (1.83)
50.0 (1.97)
400 (1312)
P20G
29
Superflexible cable
RFF 1/4”-50
Specifications
COAXIAL CABLE Type
Code
RFF 1/4”-50
NKRFF01400
RFF 1/4”-50 GHF
NKRFF01401
RFF 1/4”-50 BHF
NKRFF01402
RFF 1/4”-50 BHF (UL) CATVR
NKRFF01404
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper wire Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 1.9 mm Ø 4.8 mm Ø 6.4 mm Ø 7.4 mm
(0.07 in) (0.19 in) (0.25 in) (0.29 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 2 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.83 78.2 pF/m (22.8 pF/ft) 21000 MHz See table 0.74 kV 6.5 kW
DC-resistance • Inner conductor • Outer conductor
6.2 Ω /km 7.7 Ω /km
(1.89 Ω /1000 ft) (2.34 Ω /1000 ft)
30
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFF 1/4”-50
Black, halogen free polyethylene
yes
no
no
yes
no
-40°C (-40°F)
RFF 1/4”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFF 1/4”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFF 1/4”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Superflexible cable RFF 1/4”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 4000 6000 8000 20400
1.79 3.12 4.04 5.38 5.74 5.97 7.61 8.17 10.1 11.7 12.4 13.1 13.3 14.4 15.6 16.7 17.3 17.7 17.8 18.3 18.4 18.8 20.7 22.4 24.1 25.6 26.4 27.1 28.6 29.9 31.2 32.5 33.8 36.1 39.5 49.4 58.1 100.0
(0.547) (0.950) (1.230) (1.64) (1.75) (1.82) (2.32) (2.49) (3.07) (3.56) (3.78) (3.99) (4.04) (4.39) (4.75) (5.10) (5.26) (5.39) (5.42) (5.58) (5.61) (5.73) (6.30) (6.84) (7.34) (7.82) (8.05) (8.27) (8.70) (9.12) (9.52) (9.91) (10.3) (11.0) (12.0) (15.1) (17.7) (30.5)
3.6 2.0 1.6 1.2 1.1 1.1 0.84 0.79 0.64 0.55 0.52 0.49 0.49 0.45 0.41 0.39 0.37 0.36 0.36 0.35 0.35 0.34 0.31 0.29 0.27 0.25 0.25 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 0.13 0.12 0.07
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.09 kg/m 780 N
(0.06 lb/ft) (172 lb)
12.5 mm (0.5 in) 25 mm (1.0 in) -55...+80°C (-67...+176°F) 2.3 kg/mm (129 lb/in) 1.1 Nm (0.8 lb-ft) 0.5 m (1.7 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFF 1/4”
P5C
(ft)
250 (820)
Outer diam. (D) cm (in) 53 (21)
Outer width (W) cm (in) 50
(20)
Drum weight (empty) kg (lb) 9 (20)
Total weight (lb)
Drum freight volume m3 (cu.ft)
37 (81)
0.14 (4.94)
kg
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC2014120
7-16 female
NKC2014220
N male
NKC2014320
N female
NKC2014420
N male Right angle
NKC2014620
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
31
Superflexible cable
RFF 3/8”-50
Specifications
COAXIAL CABLE Type
Code
RFF 3/8”-50
NKRFF03800
RFF 3/8”-50 GHF
NKRFF03801
RFF 3/8”-50 BHF
NKRFF03802
RFF 3/8”-50 BHF (UL) CATVR
NKRFF03804
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 2.6 mm Ø 6.5 mm Ø 9.0 mm Ø 10.1 mm
(0.10 in) (0.26 in) (0.35 in) (0.40 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.81 82 pF/m (25.0 pF/ft) 15200 MHz See table 1.04 kV 13.2 kW
DC-resistance • Inner conductor • Outer conductor
5.1 Ω/km 6.1 Ω/km
(1.55 Ω/1000 ft) (1.86 Ω/1000 ft)
32
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFF 3/8”-50
Black, halogen free polyethylene
yes
no
no
yes
no
-40°C (-40°F)
RFF 3/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFF 3/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFF 3/8”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Superflexible cable RFF 3/8”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 4000 6000 8000 15200
1.30 2.27 2.94 3.93 4.20 4.37 5.59 6.01 7.44 8.65 9.21 9.74 9.86 10.7 11.7 12.5 12.9 13.3 13.4 13.8 13.8 14.1 15.6 17.0 18.3 19.6 20.2 20.7 21.9 23.0 24.0 25.1 26.1 28.0 30.8 39.1 46.5 69.4
(0.397) (0.692) (0.897) (1.20) (1.28) (1.33) (1.71) (1.83) (2.27) (2.64) (2.81) (2.97) (3.01) (3.27) (3.55) (3.82) (3.95) (4.05) (4.07) (4.19) (4.22) (4.31) (4.76) (5.18) (5.58) (5.96) (6.14) (3.32) (6.67) (7.00) (7.33) (7.65) (7.95) (8.55) (9.39) (11.9) (14.2) (21.1)
6.0 3.4 2.6 2.0 1.9 1.8 1.4 1.3 1.1 0.90 0.84 0.80 0.79 0.73 0.67 0.62 0.60 0.59 0.58 0.57 0.56 0.55 0.50 0.46 0.43 0.40 0.39 0.38 0.36 0.34 0.33 0.31 0.30 0.28 0.26 0.20 0.17 0.12
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.12 kg/m 600 N
(0.08 lb/ft) (132 lb)
13 mm (0.5 in) 25 mm (1 in) -55...+80°C (-67...+176°F) 3.3 kg/mm (185 lb/in) 2.3 Nm (1.7 lb-ft) 1.0 m (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFF 3/8”
P5C
(ft)
250 (820)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
Drum weight (empty) kg (lb)
53 (21)
50 (20)
9 (20)
Total weight (lb)
Drum freight volume m3 (cu.ft)
45 (98)
0.14 (4.94)
kg
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC2038100
7-16 female
NKC2038200
N male
NKC2038300
N female
NKC2038400
7-16 male Right angle
NKC2038500
N male Right angle
NKC2038600
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
33
Superflexible cable
RFF 1/2”-50
Specifications
COAXIAL CABLE Type
Code
RFF 1/2”-50
NKRFF01200
RFF 1/2”-50 GHF
NKRFF01201
RFF 1/2”-50 BHF
NKRFF01202
RFF 1/2”-50 BHF (UL) CATVR
NKRFF01204
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 3.55 mm Ø 9.0 mm Ø 11.9 mm Ø 13.5 mm
(0.14 in) (0.35 in) (0.47 in) (0.53 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.82 82 pF/m (25 pF/ft) 12 500 MHz See table 1.39 kV 19.0 kW
DC-resistance • Inner conductor • Outer conductor
2.57 Ω/km 3.10 Ω/km
(0.78 Ω/1000 ft) (0.94 Ω/1000 ft)
34
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFF 1/2”-50
Black, halogen free polyethylene
yes
no
no
yes
no
-40°C (-40°F)
RFF 1/2”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFF 1/2”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFF 1/2”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Superflexible cable RFF 1/2”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 4000 6000 8000 12400
0.972 1.70 2.20 2.94 3.14 3.27 4.18 4.50 5.56 6.48 6.89 7.29 7.38 8.04 8.73 9.38 9.70 9.94 10.0 10.3 10.4 10.6 11.7 12.7 13.7 14.7 15.1 15.5 16.4 17.2 18.0 18.8 19.6 21.0 23.1 29.4 35.0 45.9
(0.296) (0.517) (0.671) (0.896) (0.957) (0.996) (1.28) (1.37) (1.70) (1.97) (2.10) (2.22) (2.25) (2.45) (2.66) (2.86) (2.96) (3.03) (3.05) (3.14) (3.16) (3.23) (3.57) (3.88) (4.18) (4.47) (4.60) (4.74) (5.00) (5.25) (5.50) (5.73) (5.97) (6.41) (7.05) (8.95) (10.7) (14.0)
8.4 4.8 3.7 2.7 2.6 2.5 1.9 1.8 1.4 1.2 1.2 1.1 1.1 0.99 0.91 0.85 0.82 0.80 0.79 0.77 0.77 0.75 0.68 0.62 0.58 0.54 0.52 0.51 0.48 0.46 0.44 0.42 0.40 0.37 0.34 0.27 0.22 0.17
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.19 kg/m 900 N
(0.13 lb/ft) (198 lb)
15 mm 30 mm -55...+80°C 3.4 kg/mm 2.7 Nm 1.0 m
(0.6 in) (1.2 in) (-67...+176°F) (190 lb/in) (2.0 lb-ft) (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFF 1/2”
P11D
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
Drum weight (empty) kg (lb)
114 (45)
51 (20)
45 (99)
Total weight kg
(lb)
156 (346)
Drum freight volume m3 (cu.ft) 0.66 (23.31)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC2012100
7-16 female
NKC2012200
N male
NKC2012300
N female
NKC2012400
7-16 male Right angle
NKC2012500
N male Right angle
NKC2012600
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
35
Extraflexible cable
RFE 7/8”-50
Specifications
COAXIAL CABLE Type
Code
RFE 7/8”-50
NKRFE07800
RFE 7/8”-50 GHF
NKRFE07801
RFE 7/8”-50 BHF
NKRFE07802
RFE 7/8”-50 BHF (UL) CATVR
NKRFE07804
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Corrugated copper tube Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 9.4 mm Ø 21.7 mm Ø 24.9 mm Ø 27.5 mm
(0.37 in) (0.85 in) (0.98 in) (1.08 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.88 74.3 pF/m (22.7 pF/ft) 5200 MHz See table 2.8 kV 91.3 kW
DC-resistance • Inner conductor • Outer conductor
2.50 Ω/km (0.76 Ω/1000 ft) 1.07 Ω/km (0.32 Ω/1000 ft)
36
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
UL Rated
Min. installation temperature
JACKETING OPTIONS Type
RFE 7/8”-50
Black, halogen free polyethylene
yes
no
no
yes
no
-40°C (-40°F)
RFE 7/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
no
-20°C (-4°F)
RFE 7/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
no
-20°C (-4°F)
RFE 7/8”-50 BHF (UL) CATVR
Black, halogen free fire retardant UL Riser rated jacket
yes
yes
yes
yes
yes
-20°C (-4°F)
Extraflexible cable RFE 7/8”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 4000 5000
0.380 0.663 0.861 1.15 1.23 1.28 1.64 1.77 2.19 2.55 2.72 2.88 2.92 3.18 3.46 3.72 3.84 3.94 3.97 4.09 4.11 4.21 4.65 5.07 5.47 5.85 6.03 6.21 6.56 6.90 7.23 7.55 7.86 8.46 9.32 10.7
(0.116) (0.202) (0.263) (0.351) (0.375) (0.391) (0.501) (0.539) (0.668) (0.778) (0.829) (0.878) (0.889) (0.969) (1.05) (1.13) (1.17) (1.20) (1.21) (1.25) (1.25) (1.28) (1.42) (1.55) (1.67) (1.78) (1.84) (1.89) (2.00) (2.10) (2.20) (2.30) (2.40) (2.58) (2.84) (3.25)
24 14 11 8.0 7.5 7.2 5.6 5.2 4.2 3.6 3.4 3.2 3.1 2.9 2.6 2.5 2.4 2.3 2.3 2.2 2.2 2.2 2.0 1.8 1.7 1.6 1.5 1.5 1.4 1.3 1.3 1.2 1.2 1.1 0.98 0.86
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp spacing
0.43 kg/m 1500 N
(0.29 lb/ft) (330 lb)
90 mm (3.5 in) 120 mm (4.7 in) -55...+80°C (-67...+176°F) 1.6 kg/mm (90 lb/in) 15.7 Nm (11.6 lb-ft) 1.0 m (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFE 7/8”
P13G
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
Drum weight (empty) kg (lb)
134 (52)
70 (28)
69 (152)
Total weight kg
(lb)
315 (696)
Drum freight volume m3 (cu.ft) 1.24 (44.50)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1078100
7-16 female
NKC1078200
7-16 Bulkhead female
NKC1078290
N male
NKC1078300
N female
NKC1078400
7-16 male Right angle
NKC1078500
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
37
Extraflexible cable
RFE 1 1/4”-50
Specifications
COAXIAL CABLE Type
Code
RFE 1 1/4”-50
NKRFE11400
RFE 1 1/4”-50 GHF
NKRFE11401
RFE 1 1/4”-50 BHF
NKRFE11402
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Corrugated copper tube Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 13.6 mm Ø 32.2 mm Ø 35.8 mm Ø 39.0 mm
(0.53 in) (1.27 in) (1.41 in) (1.53 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1 Ω
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.88 74.6 pF/m (22.7 pF/ft) 3700 MHz See table 4.5 kV 187.2 kW
DC-resistance • Inner conductor • Outer conductor
1.24 Ω/km (0.38 Ω/1000 ft) 0.59 Ω/km (0.18 Ω/1000 ft)
38
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFE 1 1/4”-50
Black, halogen free polyethylene (LDPE with HDPE skin)
yes
no
no
yes
-40°C (-40°F)
RFE 1 1/4”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
-5°C (+23°F)
RFE 1 1/4”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
-5°C (+23°F)
Extraflexible cable RFE 1 1/4”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3300
0.256 0.449 0.584 0.784 0.838 0.873 1.12 1.21 1.51 1.76 1.88 1.99 2.02 2.21 2.40 2.59 2.68 2.75 2.77 2.86 2.87 2.94 3.27 3.57 3.86 4.14 4.28 4.41 4.67 4.92 5.17 5.40 5.64 5.98
(0.078) (0.137) (0.178) (0.239) (0.256) (0.266) (0.343) (0.369) (0.459) (0.537) (0.537) (0.607) (0.615) (0.672) (0.733) (0.790) (0.817) (0.839) (0.844) (0.871) (0.876) (0.897) (0.996) (1.09) (1.18) (1.26) (1.30) (1.34) (1.42) (1.50) (1.57) (1.65) (1.72) (1.82)
38 22 17 12 12 11 8.6 8.0 6.4 5.5 5.1 4.8 4.8 4.4 4.0 3.7 3.6 3.5 3.5 3.4 3.4 3.3 3.0 2.7 2.5 2.3 2.2 2.2 2.1 2.0 1.9 1.8 1.7 1.6
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance
0.79 kg/m 5100 N
(0.53 lb/ft) (1124 lb)
120 mm (4.7 in) 220 mm (8.7 in) -55...+80°C (-67...+176°F) 2.3 kg/mm (129 lb/in) 30.2 Nm (22.3 lb-ft) 1.5 m (5 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFE 1 1/4”
P20G
(ft)
600 (1968)
Outer diam. (D) cm (in) 204 (80)
Outer width (W) cm (in) 70 (28)
Drum weight (empty) kg (lb)
Total weight kg
(lb)
Drum freight volume m3 (cu.ft)
155 (342) 675 (1486) 3.08 (108.76)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1114100
7-16 female
NKC1114200
7-16 Bulkhead female
NKC1114290
N male
NKC1114300
N female
NKC1114400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
39
Extraflexible cable
RFE 1 5/8”-50
Specifications
COAXIAL CABLE Type
Code
RFE 1 5/8”-50
NKRFE15800
RFE 1 5/8”-50 GHF
NKRFE15801
RFE 1 5/8”-50 BHF
NKRFE15802
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Corrugated copper tube Cellular polyethylene Corrugated copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 17.5 mm Ø 42.0 mm Ø 46.5 mm Ø 50.0 mm
(0.69 in) (1.65 in) (1.83 in) (1.97 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Return loss 24 dB for 100 m (330 ft) cable with NKC connectors for following frequency bands: • 380–500 MHz • 806–960 MHz • 1710–1880 MHz • 1900–2170 MHz Other bands also available on request Bands according to customer’s specifications
50 ± 1
Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating
See attenuation table 0.88 73.8 pF/m (23 pF/ft) 2800 MHz See table 5.0 kV 284.0 kW
DC-resistance • Inner conductor • Outer conductor
1.23 Ω/km (0.37 Ω/1000 ft) 0.38 Ω/km (0.12 Ω/1000 ft)
40
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFE 1 5/8”-50
Black, halogen free polyethylene
yes
no
no
yes
-20°C (-4°F)
RFE 1 5/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
yes
yes
no
-5°C (+23°F)
RFE 1 5/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
yes
yes
yes
-5°C (+23°F)
Extraflexible cable RFE 1 5/8”-50
MECHANICAL CHARACTERISTICS
Frequency MHz
Attenuation dB/100 m
Attenuation dB/100 ft
Power rating kW
ATTENUATION
10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600
0.198 0.349 0.456 0.615 0.659 0.686 0.889 0.959 1.20 1.41 1.51 1.60 1.63 1.78 1.95 2.11 2.19 2.25 2.26 2.34 2.35 2.41 2.69 2.95 3.21 3.45 3.57 3.69 3.91 4.14 4.35
(0.060) (0.106) (0.139) (0.187) (0.201) (0.209) (0.271) (0.292) (0.366) (0.430) (0.460) (0.489) (0.496) (0.543) (0.594) (0.643) (0.666) (0.685) (0.689) (0.712) (0.716) (0.734) (0.819) (0.900) (0.977) (1.05) (1.09) (1.12) (1.19) (1.26) (1.33)
55 31 24 18 16 16 12 11 9.0 7.7 7.2 6.7 6.6 6.0 5.5 5.1 4.9 4.8 4.8 4.6 4.6 4.5 4.0 3.6 3.4 3.1 3.0 2.9 2.7 2.6 2.5
Weight Maximum pulling force Minimum bending radius • Single bending • Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance
1.19 kg/m 2700 N
(0.80 lb/ft) (595 lb)
200 mm (7.9 in) 350 mm (13.8 in) -55...+80°C (-67...+176°F) 2.1 kg/mm (118 lb/in) 48.1 Nm (35.5 lb-ft) 1.0 m (3.3 ft)
STANDARD DRUM Cable type
Drum
Standard length m
RFE 1 5/8”
P20G
(ft)
400 (1312)
Outer diam. (D) cm (in) 204 (80)
Outer width (W) cm (in) 70 (28)
Drum weight (empty) kg (lb)
Total weight
155 (342)
677 (1492) 3.08 (108.76)
kg
(lb)
Drum freight volume m3 (cu.ft)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1158100
7-16 female
NKC1158200
7-16 Bulkhead female
NKC1158290
N male
NKC1158300
N female
NKC1158400
Attenuation values are typical at ambient temperature +20ºC (+68ºF). Power rating ambient temperature +40ºC (+104ºF), inner conductor +100ºC (+212ºF).
41
42
Coaxial Antennas Draka coaxial antennas include two product
conductor and RF2X have slots in two lines
families: RFX / RF2X and RFXT. RFX and
on the outer conductor. These cables are also
RF2X cables are the best choice for multi- and
available with a suspension wire: RFXK and
broadband systems. RFXT cables are ideal when
RF2XK. RFXT cables are radiating mode cables
certain selected frequencies are required; the
with a periodically slotted and overlapped copper
performance of RFXT cables is optimized for the
tape outer conductor.
respective frequency bands. Our coaxial antennas provide a reliable way to build indoor coverage
The most important electrical characteristics
network in buildings and in tunnels.
of coaxial antennas are longitudinal attenuation and coupling loss. The excellent electrical
RFX and RF2X cables are coupled mode cables
performance of our RFX, RF2X and RFXT cables
with a corrugated and milled outer conductor.
is achieved by continuous development work and
RFX cables have slots in one line on the outer
an extensive test program.
Draka 50 Ohm Radio Frequency Cables COAXIAL ANTENNAS Type
Product code
Inner conductor diam. mm (in)
Outer conductor diam. mm (in)
Jacket diam.
Standard length
mm (in)
m (ft)
Standard drum type
RFX 1/2”-50
NKRFX01200
4.8 (0.19)
13.9 (0.55)
16.0 (0.63)
500 (1640)
P11D
RFX 7/8”-50
NKRFX07800
9.3 (0.37)
25.2 (0.99)
27.8 (1.09)
500 (1640)
P13G
RFX 1 1/4”-50
NKRFX11400
13.0 (0.51)
35.8 (1.41)
39.0 (1.54)
600 (1968)
P20G
RFX 1 5/8”-50
NKRFX15800
17.6 (0.69)
46.3 (1.82)
50.0 (1.97)
400 (1312)
P20G
RFXT 7/8”-50
NKRFXT07806
9.0 (0.35)
23.5 (0.93)
28.7 (1.13)
500 (1640)
P21G
RFXT 1 1/4”-50
NKRFXT11406
12.8 (0.50)
32.8 (1.29)
38.8 (1.53)
500 (1640)
P19Q
43
Coaxial Antennas
RFX 1/2”-50 RF2X 1/2”-50 Specifications
COAXIAL CABLE Type
Code
RFX 1/2”-50
NKRFX01200
RFX 1/2”-50 GHF
NKRFX01201
RFX 1/2”-50 BHF
NKRFX01202
RF2X 1/2”-50
NKRF2X01200
RF2X 1/2”-50 GHF
NKRF2X01201
RF2X 1/2”-50 BHF
NKRF2X01202
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper-clad aluminium wire Cellular polyethylene Corrugated slotted copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 4.8 mm (0.19 in) Ø 12.1 mm (0.48 in) Ø 13.9 mm (0.55 in) Ø 16.0 mm (0.63 in)
MECHANICAL CHARACTERISTICS Weight 0.22 kg/m Maximum pulling force 2550 N Minimum single bending radius 120 mm Operating temperature range -55...+80°C Recommended clamp spacing 1.0 m
(0.15 lb/ft) (562 lb) (4.7 in) (-67...+176°F) (3.3 ft)
44
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-1 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFX 1/2”-50 RF2X 1/2”-50
Black, halogen free polyethylene
yes
no
no
yes
-40°C (-40°F)
RFX 1/2”-50 GHF RF2X 1/2”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
no
yes
no
-20°C (-4°F)
RFX 1/2”-50 BHF RF2X 1/2”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
no
yes
yes
-20°C (-4°F)
RFX 1/2”-50 MBHF Black, halogen free fire retardant RF2X 1/2”-50 MBHF thermoplastic with mica tape
yes
yes
yes
yes
-20°C (-4°F)
Coaxial Antennas RFX 1/2”-50, RF2X 1/2”-50
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Typical return loss (VSWR) on effective frequency range Velocity factor Capacitance Maximum frequency DC-resistance • Inner conductor • Outer conductor
50 ± 2 Ω 18 dB 0.88 76 pF/m 9800 MHz 1.44 Ω/km 2.24 Ω/km
(1.29) (23 pF/ft)
(0.44 Ω/1000 ft) (0.68 Ω/1000 ft)
ATTENUATION (measured acc. to IEC 61196-4 free space method)
COUPLING LOSS (measured acc. to IEC 61196-4 free space method)
RFX 1/2”-50
RFX 1/2”-50
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
2.0 dB/100 m 2.8 dB/100 m 5.0 dB/100 m 7.3 dB/100 m 10.8 dB/100 m 11.7 dB/100 m 12.7 dB/100 m
(0.61 dB/100 ft) (0.85 dB/100 ft) (1.52 dB/100 ft) (2.23 dB/100 ft) (3.29 dB/100 ft) (3.57 dB/100 ft) (3.87 dB/100 ft)
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
63 dB 68 dB 76 dB 78 dB 79 dB 80 dB 81 dB
2.2 dB/100 m 3.1 dB/100 m 5.7 dB/100 m 8.4 dB/100 m 12.7 dB/100 m 14.0 dB/100 m 15.1 dB/100 m
(0.67 dB/100 ft) (0.94 dB/100 ft) (1.74 dB/100 ft) (2.56 dB/100 ft) (3.87 dB/100 ft) (4.27 dB/100 ft) (4.60 dB/100 ft)
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
57 dB 63 dB 69 dB 71 dB 77 dB 74 dB 76 dB
RF2X 1/2”-50 50% value
RF2X 1/2”-50 at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
50% value
95% value 69 dB 74 dB 82 dB 83 dB 86 dB 88 dB 91 dB
95% value 64 dB 68 dB 74 dB 78 dB 83 dB 81 dB 85 dB
STANDARD DRUM Cable type
Drum
Standard length m
RFX 1/2”
P11D
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
114 (45)
51 (20)
Drum weight (empty) kg (lb) 45 (99)
Total weight kg
(lb)
170 (375)
Drum freight volume m3 (cu.ft) 0.66 (23.31)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1012100
7-16 female
NKC1012200
N male
NKC1012300
N female
NKC1012400
7-16 male Right angle
NKC1012500
N male Right angle
NKC1012600
45
Coaxial Antennas
RFX 7/8”-50 RF2X 7/8”-50 Specifications
COAXIAL CABLE Type
Code
RFX 7/8”-50
NKRFX07800
RFX 7/8”-50 GHF
NKRFX07801
RFX 7/8”-50 BHF
NKRFX07802
RF2X 7/8”-50
NKRF2X07800
RF2X 7/8”-50 GHF
NKRF2X07801
RF2X 7/8”-50 BHF
NKRF2X07802
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper tube Cellular polyethylene Corrugated slotted copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 9.3 mm Ø 22.0 mm Ø 25.2 mm Ø 27.8 mm
(0.37 in) (0.86 in) (0.99 in) (1.09 in)
MECHANICAL CHARACTERISTICS Weight 0.46 kg/m Maximum pulling force 2800 N Minimum single bending radius 240 mm Operating temperature range -55...+80°C Recommended clamp spacing 1.0 m
(0.31 lb/ft) (617 lb) (9.4 in) (-67...+176°F) (3.3 ft)
46
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFX 7/8”-50 RF2X 7/8”-50
Black, halogen free polyethylene
yes
no
no
yes
-40°C (-40°F)
RFX 7/8”-50 GHF RF2X 7/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
no
yes
no
-20°C (-4°F)
RFX 7/8”-50 BHF RF2X 7/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
no
yes
yes
-20°C (-4°F)
RFX 7/8”-50 MBHF Black, halogen free fire retardant RF2X 7/8”-50 MBHF thermoplastic with mica tape
yes
yes
yes
yes
-20°C (-4°F)
Coaxial Antennas RFX 7/8”-50, RF2X 7/8”-50
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Typical return loss (VSWR) on effective frequency range Velocity factor Capacitance Maximum frequency DC-resistance • Inner conductor • Outer conductor
50 ± 2 Ω 18 dB 0.90 73 pF/m 5100 MHz 1.11 Ω/km 1.11 Ω/km
(1.29) (22.3 pF/ft)
(0.34 Ω/1000 ft) (0.34 Ω/1000 ft)
ATTENUATION (measured acc. to IEC 61196-4 free space method)
COUPLING LOSS (measured acc. to IEC 61196-4 free space method)
RFX 7/8”-50
RFX 7/8”-50
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
1.2 dB/100 m 1.6 dB/100 m 3.0 dB/100 m 4.5 dB/100 m 6.9 dB/100 m 7.9 dB/100 m 8.6 dB/100 m
1.4 dB/100 m 1.8 dB/100 m 3.5 dB/100 m 5.4 dB/100 m 8.8 dB/100 m 10.0 dB/100 m 11.3 dB/100 m
(0.37 dB/100 ft) (0.49 dB/100 ft) (0.91 dB/100 ft) (1.37 dB/100 ft) (2.10 dB/100 ft) (2.41 dB/100 ft) (2.62 dB/100 ft)
RF2X 7/8”-50 at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
(0.43 dB/100 ft) (0.55 dB/100 ft) (1.07 dB/100 ft) (1.65 dB/100 ft) (2.68 dB/100 ft) (3.05 dB/100 ft) (3.44 dB/100 ft)
50% value
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
51 dB 63 dB 69 dB 70 dB 72 dB 71 dB 77 dB
RF2X 7/8”-50
50% value
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
49 dB 57 dB 62 dB 64 dB 65 dB 67 dB 68 dB
61 dB 69 dB 73 dB 78 dB 77 dB 76 dB 84 dB
95% value
95% value 55 dB 62 dB 69 dB 71 dB 71 dB 74 dB 77 dB
STANDARD DRUM Cable type
Drum
Standard length m
RFX 7/8”
P13G
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
134 (52)
70 (28)
Drum weight (empty) kg (lb) 69 (152)
Total weight kg
(lb)
330 (728)
Drum freight volume m3 (cu.ft) 1.26 (44.50)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1078100
7-16 female
NKC1078200
7-16 Bulkhead female
NKC1078290
N male
NKC1078300
N female
NKC1078400
7-16 male Right angle
NKC1078500
47
Coaxial Antennas
RFX 1 1/4”-50 RF2X 1 1/4”-50 Specifications
COAXIAL CABLE Type
Code
RFX 1 1/4”-50
NKRFX11400
RFX 1 1/4”-50 GHF
NKRFX11401
RFX 1 1/4”-50 BHF
NKRFX11402
RF2X 1 1/4”-50
NKRF2X11400
RF2X 1 1/4”-50 GHF
NKRF2X11401
RF2X 1 1/4”-50 BHF
NKRF2X11402
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Copper tube Cellular polyethylene Corrugated slotted copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 13.0 mm Ø 32.2 mm Ø 35.8 mm Ø 39.0 mm
(0.51 in) (1.27 in) (1.41 in) (1.54 in)
MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Operating temperature range Recommended clamp spacing
0.86 kg/m 6050 N 350 mm -55...+80°C 1.5 m
(0.58 lb/ft) (1340 lb) (14 in) (-67...+176°F) (5 ft)
48
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFX 1 1/4”-50 RF2X 1 1/4”-50
Black, halogen free polyethylene
yes
no
no
yes
-40°C (-40°F)
RFX 1 1/4”-50 GHF RF2X 1 1/4”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
no
yes
no
-5°C (+23°F)
RFX 1 1/4”-50 BHF RF2X 1 1/4”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
no
yes
yes
-5°C (+23°F)
RFX 1 1/4”-50 MBHF Black, halogen free fire retardant RF2X 1 1/4”-50 MBHF thermoplastic with mica tape
yes
yes
yes
yes
-5°C (+23°F)
Coaxial Antennas RFX 1 1/4”-50, RF2X 1 1/4”-50
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Typical return loss (VSWR) on effective frequency range Velocity factor Capacitance Maximum frequency DC-resistance • Inner conductor • Outer conductor
50 ± 2 Ω 18 dB 0.88 75 pF/m 3500 MHz 0.74 Ω/km 0.65 Ω/km
(1.29) (23 pF/ft)
(0.22 Ω/1000 ft) (0.20 Ω/1000 ft)
ATTENUATION (measured acc. to IEC 61196-4 free space method)
COUPLING LOSS (measured acc. to IEC 61196-4 free space method)
RFX 1 1/4”-50
RFX 1 1/4”-50 50% value
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
0.9 dB/100 m 1.1 dB/100 m 2.2 dB/100 m 3.2 dB/100 m 5.4 dB/100 m 6.1 dB/100 m 6.8 dB/100 m
(0.27 dB/100 ft) (0.34 dB/100 ft) (0.67 dB/100 ft) (0.98 dB/100 ft) (1.65 dB/100 ft) (1.86 dB/100 ft) (2.07 dB/100 ft)
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
1.0 dB/100 m 1.4 dB/100 m 2.5 dB/100 m 4.1 dB/100 m 7.9 dB/100 m 9.1 dB/100 m 11.2 dB/100 m
(0.30 dB/100 ft) (0.43 dB/100 ft) (0.76 dB/100 ft) (1.25 dB/100 ft) (2.41 dB/100 ft) (2.77 dB/100 ft) (3.41 dB/100 ft)
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
47 dB 54 dB 64 dB 64 dB 64 dB 65 dB 64 dB
95% value 60 dB 69 dB 76 dB 76 dB 75 dB 72 dB 73 dB
RF2X 1 1/4”-50 50% value
RF2X 1 1/4”-50 at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
53 dB 62 dB 70 dB 71 dB 71 dB 68 dB 68 dB
95% value 53 dB 60 dB 71 dB 71 dB 70 dB 71 dB 71 dB
STANDARD DRUM Cable type
Drum
Standard length m
RFX 1 1/4”
P20G
(ft)
600 (1968)
Outer diam. (D) cm (in) 204 (80)
Outer width (W) cm (in) 70 (28)
Drum weight (empty) kg (lb)
Total weight kg
(lb)
Drum freight volume m3 (cu.ft)
155 (342) 717 (1584) 3.08 (108.76)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1114100
7-16 female
NKC1114200
7-16 Bulkhead female
NKC1114290
N male
NKC1114300
N female
NKC1114400
49
Coaxial Antennas
RFX 1 5/8”-50 RF2X 1 5/8”-50 Specifications
COAXIAL CABLE Type
Code
RFX 1 5/8”-50
NKRFX15800
RFX 1 5/8”-50 GHF
NKRFX15801
RFX 1 5/8”-50 BHF
NKRFX15802
RF2X 1 5/8”-50
NKRF2X15800
RF2X 1 5/8”-50 GHF
NKRF2X15801
RF2X 1 5/8”-50 BHF
NKRF2X15802
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacket Marking
Corrugated copper tube Cellular polyethylene Corrugated slotted copper tube See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 17.6 mm Ø 42.0 mm Ø 46.3 mm Ø 50.0 mm
(0.69 in) (1.65 in) (1.82 in) (1.97 in)
MECHANICAL CHARACTERISTICS Weight 1.13 kg/m Maximum pulling force 3750 N Minimum single bending radius 400 mm Operating temperature range -55...+80°C Recommended clamp spacing 1.5 m
(0.76 lb/ft) (826 lb) (15.7 in) (-67...+176°F) (5 ft)
50
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFX 1 5/8”-50 RF2X 1 5/8”-50
Black, halogen free polyethylene
yes
no
no
yes
-40°C (-40°F)
RFX 1 5/8”-50 GHF RF2X 1 5/8”-50 GHF
Grey, halogen free fire retardant thermoplastic
yes
no
yes
no
-5°C (+23°F)
RFX 1 5/8”-50 BHF RF2X 1 5/8”-50 BHF
Black, halogen free fire retardant thermoplastic
yes
no
yes
yes
-5°C (+23°F)
RFX 1 5/8”-50 MBHF Black, halogen free fire retardant RF2X 1 5/8”-50 MBHF thermoplastic with mica tape
yes
yes
yes
yes
-5°C (+23°F)
Coaxial Antennas RFX 1 5/8”-50, RF2X 1 5/8”-50
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Typical return loss (VSWR) on effective frequency range Velocity factor Capacitance Maximum frequency DC-resistance • Inner conductor • Outer conductor
50 ± 2 Ω 18 dB 0.89 74 pF/m 2800 MHz 1.16 Ω/km 0.43 Ω/km
(1.29) (22.6 pF/ft)
(0.35 Ω/1000 ft) (0.13 Ω/1000 ft)
ATTENUATION (measured acc. to IEC 61196-4 free space method)
COUPLING LOSS (measured acc. to IEC 61196-4 free space method)
RFX 1 5/8”-50
RFX 1 5/8”-50 50% value
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
0.7 dB/100 m 0.9 dB/100 m 1.7 dB/100 m 2.7 dB/100 m 4.6 dB/100 m 5.2 dB/100 m 6.2 dB/100 m
(0.21 dB/100 ft) (0.27 dB/100 ft) (0.52 dB/100 ft) (0.82 dB/100 ft) (1.40 dB/100 ft) (1.58 dB/100 ft) (1.89 dB/100 ft)
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
RF2X 1 5/8”-50 50% value
RF2X 1 5/8”-50 at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
53 dB 63 dB 68 dB 68 dB 69 dB 67 dB 68 dB
0.7 dB/100 m 1.0 dB/100 m 1.9 dB/100 m 3.0 dB/100 m 5.5 dB/100 m 6.4 dB/100 m 7.5 dB/100 m
(0.21 dB/100 ft) (0.30 dB/100 ft) (0.58 dB/100 ft) (0.91 dB/100 ft) (1.68 dB/100 ft) (1.95 dB/100 ft) (2.29 dB/100 ft)
at 75 MHz at 150 MHz at 450 MHz at 900 MHz at 1.8 GHz at 2.1 GHz at 2.4 GHz
50 dB 58 dB 63 dB 64 dB 66 dB 65 dB 66 dB
95% value 60 dB 69 dB 73 dB 73 dB 75 dB 72 dB 74 dB 95% value 56 dB 63 dB 67 dB 72 dB 73 dB 72 dB 74 dB
STANDARD DRUM Cable type
Drum
Standard length m
RFX 1 5/8”
P20G
(ft)
400 (1312)
Outer diam. (D) cm (in) 204 (80)
Outer width (W) cm (in) 70 (28)
Drum weight (empty) kg (lb)
Total weight
155 (342)
653 (1440) 3.08 (108.76)
kg
(lb)
Drum freight volume m3 (cu.ft)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC1158100
7-16 female
NKC1158200
7-16 Bulkhead female
NKC1158290
N male
NKC1158300
N female
NKC1158400
51
Coaxial Antennas
RFXT 7/8”-50 MBHF Specifications
COAXIAL CABLE Type
Code
RFXT 7/8”-50 MGHF
NKRFXT07806
RFXT 7/8”-50 MBHF
NKRFXT07807
CONSTRUCTION Inner conductor Dielectric Outer conductor Fire barrier Jacket Marking
Copper tube Cellular polyethylene Copper tape with periodic slots Mica tape See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 9.0 mm Ø 23.2 mm Ø 23.5 mm Ø 23.7 mm Ø 28.7 mm
(0.35 in) (0.91 in) (0.93 in) (0.93 in) (1.13 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Typical return loss (VSWR) on effective frequency range Velocity factor Capacitance Maximum frequency DC-resistance • Inner conductor • Outer conductor
50 ± 2 Ω 18 dB 0.88 76 pF/m 5100 MHz 1.16 Ω/km 1.11 Ω/km
(1.29) (23 pF/ft)
(0.35 Ω/1000 ft) (0.45 Ω/1000 ft)
52
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFXT 7/8”-50 MGHF
Grey, halogen free fire retardant thermoplastic with mica tape
yes
yes
yes
no
-20°C (-4°F)
RFXT 7/8”-50 MBHF
Black, halogen free fire retardant thermoplastic with mica tape
yes
yes
yes
yes
-20°C (-4°F)
Coaxial Antennas RFXT 7/8”-50 MBHF
MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum single bending radius Operating temperature range Recommended clamp spacing
0.66 kg/m (0.44 lb/ft) 2300 N (507 lb) 400 mm (17 in) -55...+80°C (-67...+176°F) 1.0 m (3.3 ft)
ATTENUATION (measured acc. to IEC 61196-4 free space method) at 150 MHz 1.9 dB/100m at 450 MHz 3.2 dB/100m at 900 MHz 5.0 dB/100m at 1.8 GHz 8.0 dB/100m
(0.58 dB/100ft) (0.98 dB/100ft) (1.52 dB/100ft) (2.44 dB/100ft)
COUPLING LOSS (measured acc. to IEC 61196-4 free space method)
50% value
at 150 MHz 70 dB at 450 MHz 65 dB at 900 MHz 65 dB at 1.8 GHz 67 dB
95% value 76 dB 68 dB 71 dB 72 dB
STANDARD DRUM Cable type
Drum
Standard length m
RFXT 7/8”
P20G
(ft)
500 (1640)
Outer diam. (D) cm (in) 204 (80)
Outer width (W) cm (in) 70 (28)
Drum weight (empty) kg (lb)
Total weight
155 (342)
531 (1170)
kg
(lb)
Drum freight volume m3 (cu.ft) 3.08 (108.76)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC3078120
7-16 female
NKC3078220
N male
NKC3078320
N female
NKC3078420
53
Coaxial Antennas
RFXT 1 1/4”-50 MBHF Specifications
COAXIAL CABLE Type
Code
RFXT 1 1/4”-50 MGHF
NKRFXT11406
RFXT 1 1/4”-50 MBHF
NKRFXT11407
CONSTRUCTION Inner conductor Dielectric Outer conductor Fire barrier Jacket Marking
Copper tube Cellular polyethylene Copper tape with periodic slots Mica tape See Jacketing Options table below Draka, cable type, manufacture week, year, batch number and meter mark
Ø 12.8 mm Ø 32.5 mm Ø 32.8 mm Ø 33.0 mm Ø 38.8 mm
(0.50 in) (1.28 in) (1.29 in) (1.30 in) (1.53 in)
ELECTRICAL CHARACTERISTICS at +20°C (+ 68°F) Characteristic impedance Typical return loss (VSWR) on effective frequency range Velocity factor Capacitance Maximum frequency DC-resistance • Inner conductor • Outer conductor
50 ± 2 Ω 18 dB 0.88 76 pF/m 3500 MHz
(1.29) (23 pF/ft)
0.63 Ω/km (0.19 Ω/1000 ft) 1.14 Ω/km (0.35 Ω/1000 ft)
54
Jacket
IEC 60754 -1/-2 halogen free, non corrosive
IEC 61034 low smoke emission
IEC 60332-3-24 fire retardant
UV Retardancy
Min. installation temperature
JACKETING OPTIONS Type
RFXT 1 1/4”-50 MGHF
Grey, halogen free fire retardant thermoplastic with mica tape
yes
yes
yes
no
-5°C (+23°F)
RFXT 1 1/4”-50 MBHF
Black, halogen free fire retardant thermoplastic with mica tape
yes
yes
yes
yes
-5°C (+23°F)
Coaxial Antennas RFXT 1 1/4”-50 MBHF
MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum single bending radius Operating temperature range Recommended clamp spacing
0.910 kg/m (0.61 lb/ft) 3000 N (664 lb) 450 mm (18 in) -55...+80°C (-67...+176°F) 1.5 m (5 ft)
ATTENUATION (measured acc. to IEC 61196-4 free space method) at 150 MHz 1.1 dB/100m at 450 MHz 2.1 dB/100m at 900 MHz 3.0 dB/100m at 1.8 GHz 5.2 dB/100m
(0.34 dB/100ft) (0.64 dB/100ft) (0.91 dB/100ft) (1.59 dB/100ft)
COUPLING LOSS (measured acc. to IEC 61196-4 free space method)
50% value
at 150 MHz 76 dB at 450 MHz 67 dB at 900 MHz 69 dB at 1.8 GHz 64 dB
95% value
82 dB 74 dB 75 dB 70 dB
STANDARD DRUM Cable type
Drum
Standard length m
RFXT 1 1/4”
P19Q
(ft)
500 (1640)
Outer diam. (D) cm (in)
Outer width (W) cm (in)
194 (76)
102 (40)
Drum weight (empty) kg (lb) 141 (311)
Total weight kg
(lb)
Drum freight volume m3 (cu.ft)
672 (1478) 3.99 (140.89)
CODES FOR NKC CONNECTORS Connector type
Code
7-16 male
NKC3114120
7-16 female
NKC3114220
N male
NKC3114320
N female
NKC3114420
55
Jumpers
Jumpers with superflexible RFF 1/2” cable Draka jumper cables are the perfect choice for antenna line connections. Our jumpers have excellent return loss values with low and stable intermodulation. Stable electrical performance is ensured by high quality superflexible cable and special connector head design. Soldered inner and outer conductor guarantees excellent return loss and low intermodulation. The design of the assembly ensures the waterproofness of the jumper to IP 68. The design is based on three main principles: • 7-16 head sealing with O-rings • Induction soldering of the inner and outer conductors providing 360 degrees of contact and sealing • Enclosing the connection at the rear of the connector with injection molded body All our jumpers are delivered with an attached test report. Additional protection is maintained during storage and transport by a watertight protective cap on each end.
56
Jumpers
A test report shows return loss measurements. For traceability, a weatherproof ID label is attached to each jumper.
JUMPERS RFF 1/2”cable length Connectors Male 7/16
0.5 m
1m
1.5 m
2m
2.5 m
3m
4m
5m
NKJ 11
NKJ 111
NKJ 112
NKJ 113
NKJ 114
NKJ 115
NKJ 116
NKJ 118
NKJ 1110
NKJ 12
NKJ 121
NKJ 122
NKJ 123
NKJ 124
NKJ 125
NKJ 126
NKJ 128
NKJ 1210
NKJ 13
NKJ 131
NKJ 132
NKJ 133
NKJ 134
NKJ 135
NKJ 136
NKJ 138
NKJ 1310
NKJ 14
NKJ 141
NKJ 142
NKJ 143
NKJ 144
NKJ 145
NKJ 146
NKJ 148
NKJ 1410
NKJ 15
NKJ 151
NKJ 152
NKJ 153
NKJ 154
NKJ 155
NKJ 156
NKJ 158
NKJ 1510
NKJ 16
NKJ 161
NKJ 162
NKJ 163
NKJ 164
NKJ 165
NKJ 166
NKJ 168
NKJ 1610
NKJ 22
NKJ 221
NKJ 222
NKJ 223
NKJ 224
NKJ 225
NKJ 226
NKJ 228
NKJ 2210
NKJ 23
NKJ 231
NKJ 232
NKJ 233
NKJ 234
NKJ 235
NKJ 236
NKJ 238
NKJ 2310
NKJ 24
NKJ 241
NKJ 242
NKJ 243
NKJ 244
NKJ 245
NKJ 246
NKJ 248
NKJ 2410
NKJ 25
NKJ 251
NKJ 252
NKJ 253
NKJ 254
NKJ 255
NKJ 256
NKJ 258
NKJ 2510
NKJ 26
NKJ 261
NKJ 262
NKJ 263
NKJ 264
NKJ 265
NKJ 266
NKJ 268
NKJ 2610
NKJ 33
NKJ 331
NKJ 332
NKJ 333
NKJ 334
NKJ 335
NKJ 336
NKJ 338
NKJ 3310
NKJ 34
NKJ 341
NKJ 342
NKJ 343
NKJ 344
NKJ 345
NKJ 346
NKJ 348
NKJ 3410
NKJ 35
NKJ 351
NKJ 352
NKJ 353
NKJ 354
NKJ 355
NKJ 356
NKJ 358
NKJ 3510
NKJ 36
NKJ 361
NKJ 362
NKJ 363
NKJ 364
NKJ 365
NKJ 366
NKJ 368
NKJ 3610
NKJ 44
NKJ 441
NKJ 442
NKJ 443
NKJ 444
NKJ 445
NKJ 446
NKJ 448
NKJ 4410
NKJ 45
NKJ 451
NKJ 452
NKJ 453
NKJ 454
NKJ 455
NKJ 456
NKJ 458
NKJ 4510
NKJ 46
NKJ 461
NKJ 462
NKJ 463
NKJ 464
NKJ 465
NKJ 466
NKJ 468
NKJ 4610
Male 7/16
Male 7/16
Female 7/16
Male 7/16
Male N
Male 7/16
Female N
Male 7/16
Male 7/16 90°
Male 7/16
Male N 90°
Female 7/16
Female 7/16
Female 7/16
Female 7/16
Male N
Female N
Female 7/16 Male 7/16 90°
Female 7/16
Male N
Male N
Male N
Male N
Female N
Female N
Female N
Male N 90°
Male N
Female N
Male 7/16 90°
Male N 90°
Female N
Male 7/16 90°
Male N 90°
Fire retardant jumpers for indoor applications are also available. 57
Accessories
Draka offers a wide variety of high quality accessories that are easy to install. The accessories are guaranteed to be compatible with Draka products. They are tested and reliable in all relevant environmental conditions. For more accessories and further details, please contact our sales personnel.
FEEDER CABLES Connectors 7-16 male
RFA 1/4” NKC1014100
7-16 female
-
7-16 male right angle
-
RFA 3/8”
RFA 1/2”
RFA 7/8”
RFA 7/8” AL
RFA 1 1/4”
RFA 1 5/8”
NKC1038100
NKC1012100
NKC1078100
NKC1078100
NKC1114100
NKC1158100
NKC1158100
NKC1214100
NKC1038200 NKC1012200 NKC1078200 NKC1078200 NKC1114200 NKC1158200
NKC1158200
NKC1214200
-
NKC1012500 NKC1078500 NKC1078500
-
-
RFA 1 5/8” AL
RFA 2 1/4”
-
-
N-male
NKC1014300 NKC1038300 NKC1012300 NKC1078300 NKC1078300 NKC1114300 NKC1158300
NKC1158300
NKC1214300
N-female
NKC1014400 NKC1038400 NKC1012400 NKC1078400 NKC1078400 NKC1114400 NKC1158400
N-male right angle
NKC1014600
NKC1158400
NKC1214400
-
NKC1012600
-
-
-
-
-
-
NKG201400
NKG203800
NKG101200
NKG107800
NKG107800
NKG111400
NKG115800
NKG115800
NKG121400
NKA1010
NKA1000
NKA1001
NKA1003
NKA1003
NKA1004
NKA1004 and NKA1005
NKA1004 and NKA1005
NKA1005
NKA12012
NKA12078
NKA12078
NKA12114
NKA12158
GROUNDING KITS Grounding kit
TOOLS Manual tools
Drill tools
-
-
NKA12158
NKA12214
Grounding kit tools
-
-
NKA1401222 NKA1407822 NKA1407822 NKA1411422 NKA1415822 (22) (22) (22) (22) (22)
NKA1415822 (22)
-
-
-
NKA1401226 NKA1407826 NKA1407826 NKA1411430 NKA1415830 (26) (26) (26) (30) (30)
NKA1415830 (30)
-
(Stripping length, mm)
Grounding kit tools (Stripping length, mm)
58
Accessories
Connectors • Low intermodulation • Primary weatherproofness with O-ring technology
Tools • Reduced assembly time • Guarantee of constant assembly quality
Grounding Kits • Fast and easy to install • Waterproof per IP 68 • Reusable
Weatherproofing Kits • protects connections from weather conditions
EMP-Protectors • One-piece, easy and rapid installation • No maintenance required
EMP PROTECTOR Product
Quarter-wave, gas capsulate and hybrid surge protectors to Tetra, GMS900/1800 and UMTS communication solutions
Code
NKA3000
SUPERFLEXIBLE CABLES Connectors
RFF 1/4”
RFF 3/8”
7-16 male
NKC2014120
NKC2038100
7-16 female
NKC2014220 NKC2038200
7-16 male right angle
-
-
RFF 1/2”
RFE 7/8”
NKC2012100
NKC1078100
NKC1114100
NKC1158100
NKC2012200 NKC1078200
NKC1114200
NKC1158200
NKC2012300 NKC1078500
RFE 1 1/4”
RFE 1 5/8”
-
-
N-male
NKC2014320 NKC2038300 NKC2012400 NKC1078300
NKC1114300
NKC1158300
N-female
NKC2014420 NKC2038400 NKC2012500 NKC1078400
N-male right angle
NKC2014620 NKC2038600 NKC2012600
NKC1114400
NKC1158400
-
-
-
NKG111400
NKG115800
GROUNDING KITS Grounding kit
NKG201400
NKG203800
NKG201200
NKG107800
NKA1007
NKA1008
NKA1009
NKA1003
Drill tools
-
-
NKA22012
NKA12078
NKA12114
NKA12158
Grounding kit tools
-
-
NKA1401222 (22)
NKA1407822 (22)
NKA1411422 (22)
NKA1415822 (22)
-
-
NKA1401226 (26)
NKA1407826 (26)
NKA1411430 (30)
NKA1415830 (30)
TOOLS Manual tools
(Stripping length, mm)
Grounding kit tools (Stripping length, mm)
NKA1004 and NKA1004 and NKA1005 NKA1005
59
Drums
Our tailor-made wooden cable drums are designed to meet all transportation requirements to give the best protection for our cables. The drums are made of barkless boards or plywood. They are marked with an identification mark, according to the international plant protection convention (IPPC) regulations. Special drums are available on request. Handling and transport of our drums: • Handling instructions are attached on each drum. • The reeling direction of the cable is indicated by an arrow. • For transportation and storage the cable is protected by wooden lagging. • Plastic covering is placed over the outer layer of the cable, beneath the lagging. • Cable ends are sealed with a shrinkable plastic tube. Loading instructions are available on DVD. Please contact our sales offices for these instructions.
60
Drums
1
4 Example of the wood packaging material (WPM) mark on the cable drum.
Drum label shows
3
2
1 cable type 2 length 3 gross weight 4 batch number
STANDARD DRUMS FOR CABLES Cable type
Drum
Standard length m
(ft)
Outer diam. (D) cm (in)
Inner diam. (d) cm (in)
Outer width (W) cm (in)
Inner width (w) cm (in)
Shaft hole (e) cm (in)
Drum weight (empty) kg (lb)
Ladding weight
Cable weight
Total weight
kg (lb)
kg/m (lb/ft)
kg
(lb)
Drum freight volume m3 (cu.ft)
RFA 1/4”
P6D
500 (1640)
63 (25)
33 (13)
51 (20)
43 (17)
8.2 (3.2)
13 (29)
9.5 (21)
0.12 (0.08)
83 (183)
0.20 (7.06)
RFA 3/8”
P6D
250 (820)
63 (25)
33 (13)
51 (20)
43 (17)
8.2 (3.2)
13 (29)
9.5 (21)
0.13 (0.08)
55 (117)
0.20 (7.06)
RFA 1/2”
P11D
500 (1640)
114 (45)
70 (28)
51 (20)
43 (17)
8.2 (3.2)
45 (99)
15.5 (34)
0.23 (0.15)
176 (379)
0.66 (23.31)
RFA 7/8”
P13G
500 (1640)
134 (52)
75 (29)
70 (28)
61 (24)
8.2 (3.2)
69 (152)
31 (68)
0.49 (0.33)
343 (760)
1.26 (44.50)
RFA 7/8” AL
P13G
500 (1640)
134 (52)
75 (29)
70 (28)
61 (24)
8.2 (3.2)
69 (152)
31 (68)
0.37 (0.25)
285 (630)
1.26 (44.50)
RFA 1 1/4”
P20G
600 (1968)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
0.89 (0.60)
735 (1621)
3.08 (108.76)
RFA 1 5/8”
P20G
400 (1312)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
1.16 (0.78)
665 (1466)
3.08 (108.76)
RFA 1 5/8” AL
P20G
400 (1312)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
1.16 (0.78)
665 (1466)
3.08 (108.76)
RFA 2 1/4”
P21Q
300 (984)
214 (84)
150 (59)
105 (41)
96 (38)
8.2 (3.2)
218 (481)
87 (192)
1.93 (1.30)
884 (1952)
5.40 (190.68)
RFF 1/4”
P5C
250 (820)
53 (21)
25 (10)
50 (20)
40 (16)
8.2 (3.2)
9 (20)
5.5 (12)
0.09 (0.06)
37 (81)
0.14 (4.94)
RFF 3/8”
P5C
250 (820)
53 (21)
25 (10)
50 (20)
40 (16)
8.2 (3.2)
9 (20)
5.5 (12)
0.12 (0.08)
45 (98)
0.14 (4.94)
RFF 1/2”
P11D
500 (1640)
114 (45)
70 (28)
51 (20)
43 (17)
8.2 (3.2)
45 (99)
15.5 (34)
0.19 (0.13)
156 (346)
0.66 (23.31)
RFE 7/8”
P13G
500 (1640)
134 (52)
75 (29)
70 (28)
61 (24)
8.2 (3.2)
69 (152)
31 (68)
0.43 (0.29)
315 (696)
1.24 (44.50)
RFE 1 1/4”
P20G
600 (1968)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
0.79 (0.53)
675 (1486)
3.08 (108.76)
RFE 1 5/8”
P20G
400 (1312)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
1.19 (0.80)
677 (1492)
3.08 (108.76)
RFX 1/2”
P11D
500 (1640)
114 (45)
70 (28)
51 (20)
43 (17)
8.2 (3.2)
45 (99)
15.5 (34)
0.22 (0.15)
170 (375)
0.66 (23.31)
RFX 7/8”
P13G
500 (1640)
134 (52)
75 (29)
70 (28)
61 (24)
8.2 (3.2)
69 (152)
31 (68)
0.46 (0.31)
330 (728)
1.26 (44.50)
RFX 1 1/4”
P20G
600 (1968)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
0.86 (0.58)
717 (1584)
3.08 (108.76)
RFX 1 5/8”
P20G
400 (1312)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
1.13 (0.76)
653 (1440)
3.08 (108.76)
RFXT 7/8”
P20G
500 (1640)
204 (80)
120 (47)
70 (28)
61 (24)
8.2 (3.2)
155 (342)
46 (101)
0.66 (0.44)
531 (1170)
3.08 (108.76)
RFXT 1 1/4”
P19Q
500 (1640)
194 (76)
130 (51)
102 (40)
93 (37)
8.2 (3.2)
141 (311)
76 (167)
091 (0.61)
672 (1478)
3.99 (140.89)
e D
d
w W
61
Environment and Quality
Environmental Management System Draka is committed to sustainable development. Operations and products are undergoing continuous development with an eye on reducing environmental load. Our environmental management system has been assessed, approved and audited regularly to ISO 14001:2004 Environmental Management System Standard. Environmental Statement The Environmental Policy of Draka aims at • following environmental protection legislation and regulations. • reducing adverse environmental impacts during the whole life cycle. • preventing environmental pollution and increasing recovery and recycling. • raising environmental awareness of the entire personnel through training and reviewing. • encouraging material suppliers and contractors to sustainable development activities. • openly reporting the environmental impacts of its activities and products.
62
Environment and Quality
Quality Management System The quality systems of Draka companies assessed, approved and audited regularly by certification companies are against ISO 9001. Compliance with ISO 9001:2000 standard guarantees the quality and continuous improvement of our processes. Our cables are released only after successful testing according to the appropriate requirements. The quality management systems are open to customers’ evaluation. Quality Statement Draka commits to • fulfill customers’ expectations in all processes. • provide customers with satisfying products on time. • perform customer service properly. • improve our processes constantly. • a quality concept covering everything from the products and services to overall operations.
63
Environment and Quality
64
Environment and Quality
Test Report A test report is attached to each cable drum delivered by Draka. The test report includes identification data of the cable and drum, test results of transmission characteristics and other electrical characteristics as well as test results of mechanical dimensions of the cable. Characteristic impedance is a routine measurement and it is derived from the electrical length and capacitance measurements. The tolerance in feeder cables is 50+/- 1Ω. High voltage tests verify that no breakdown occurs in insulation or jacket when high voltages are applied.
impedance variations within the cable and at its ends, at a certain frequency. The return loss is measured from both ends of the cable at 10-2700 MHz frequency band. Attenuation is determined from the ratio of the input and output power. The test report contains the attenuation values at 400, 500, 800, 900, 1000, 1800, 1900 and 2200 MHz frequencies. We also carry out a TDR (Time Domain Reflectometry) measurement in order to verify that there are no local damages in the cable.
Return loss sums up the effects of all the 65
How to contact us
How to contact us Our worldwide network of partners and local offices are at your service. To find out the closest partner to you, please contact our main sales offices in Finland, Singapore or China.
66
How to contact us
FINLAND Draka NK Cables Ltd. Office:
Oulu Plant:
Kimmeltie 1 FI-02110 Espoo Tel. +358 10 56 61 Fax. +358 9 52 98 41 E-mail:
[email protected]
Johdintie 5 FI-90630 Oulu Tel. +358 10 56 61
SINGAPORE Draka NK Cables (Asia) Pte Ltd. 171 Chin Swee Road #12-05 San Centre Singapore 169877 Tel. +65 65 33 20 12 Fax. +65 65 33 20 26
[email protected] CHINA NK Wuhan Cable Co. Ltd. DongXin Road Guanshan 430073 Wuhan China Tel. +86 27 87 77 05 33 Fax. +86 27 87 80 60 90 For more information, please visit us at www.draka.com.
67
10/2008
www.draka.com