LoRaWANTM TIC SENSOR - nke Watteco

Smart Metering Smart Building Smart Energy LoRaWANTMTIC SENSOR APPLICATIONS § Wireless AMR –Smart metering § Real time monitoring of energy consumptio...

0 downloads 44 Views 1MB Size
Smart Metering

Smart Building

Smart Energy

LoRaWANTM TIC SENSOR The TIC SENSOR is a LoRaWANTM Class C sensor radio transmitting the customer tele-information (TIC) from residential electric meters as well as data from any pulse meters (water, gas, electricity, energy) and current from 2 electrical lines by using split core current transformers.

LoRaWANTM TIC Sensor – V2.1 Updated 21/09/2017 - This document is the property of nke Watteco. Information contained within is not contractual and is susceptible to modifications without advance notice

APPLICATIONS § Wireless AMR – Smart metering § Real time monitoring of energy consumption § Building management – Monitoring of water and gas meter combined with TIC Data

§ Current consumption per usage: Monitoring of current consumption on 2 electrical lines

BENEFITS & KEY FEATURES § LoRaWANTM, Class C § Easy to deploy and use ü PTSM connector for TIC Signal ü DIN Rail 1U § 2 pulse inputs § 2 current transformer inputs § Electronic meter supported: ü CBEMM ü CBEMM-ICC ü CJE ü ICE § Data compression for batch report

QUALITY & RELIABIITY § RoHS compliant § CE Compliant § Radio-equipment directive 2014/53/UE The TIC SENSOR from nke Watteco is wireless sensor operating from any wireless network using the LoRaWANTM , Class C protocol. It has been designed to monitor and transmit the TIC data (index, base, consumption, active and reactive power, ..) from homes, offices, administrative centres and small industrial premises. Two pulse inputs allows fast and cost-effective integration of any pulse meter into a LoRaWANTM network without expensive and time-consuming cabling. Two Current Transformer inputs enables to easily measure and control the current consumption of any electrical lines up to 80A. Larger current could be measured according to end user needs upon request.

If the variation of one power, active/reactive threshold set by the generated allowing to disturbances.

of the parameter (active/reactive energy, ..) is greater than the user an alarm is automatically track and analysis electrical line

The measured parameters can be locally stored, concatenated and compressed. This unique batch mechanism significantly reduce the amount of data transmission for demanding applications such as loading curve. The standard DIN rail mount design allows easy mounting and fast connections to the electrical board.

NKE WATTECO, YOUR PARTNER IN SMART SENSORS & ACTUATORS We are a European leader in designing and manufacturing highly reliable and low power consumption smart sensors, actuators and multiprotocol remote data solutions. nke Watteco is an adopter member of the LoRa® Alliance © nkeWatteco - Head Quarter: rue Gutenberg, ZI Kerandré , 56700 Hennebont, France - Tel: 33 (0)2 97 36 10 12 Paris Office: 33, rue Pierre Marin, 91270 Vigneux sur Seine, France - Tel +33(0)1 69 52 28 31 For further information, please contact us: [email protected] - www.nke-watteco.com

LoRaWANTM TIC SENSOR TECHNICAL CHARACTERISTICS Frequency (MHz)

EU: 863-870 US: 902-928 (On demand)

Transmit Power (dBm)

+14

Receiver Sensitivity (dBm) FIRMWARE

-136

Protocol

LoRaWANTM, Class C

Transmission cycles

10mn, 1h, 12h or defined by network

Data history

Available

Activation method

Activation by Personnalization (ABP) Over-The-Air Activiation (OTAA)

Data encryption TIC

AES128

Electronic Meter supported

"Blue" electronic single-phase, multi-rate meter (CBEMM) "Blue" electronic single-phase, multi-rate meter (CBEMM - ICC upgrade) "Yellow" electronic meter (CJE) "Emeraude Customer Interface" (ICE) meter

Connector type PULSE INPUTS

PTSM

Number of input

2

Voltage (V)

3 - 30

Frequency (Hz) 1 - 100 SPLIT CORE CURRENT TRANSFORMER Number of input

2

Measure (A)

Range Accuracy

Calibration

Ready to use with Zemming Zemctk02 split core current transformer For other core current transformer a calibration might be required

(with CR Magnetics 3110/3000)

: 0 - 90 : +/- 2%

ALARMS

Active/Reactive Power

Occurs when variation is greater than the threshold set by the user

Active/Reactive Energy POWER

Occurs when variation is greater than the threshold set by the user

Power supply (VAC) INTERFACE

230

LED Indicator

Network pairing & configuration

Switches MECHANICAL FEATURES

Reset, ON/OFF

DIN Rail Dimension (mm)

1U – 89 x 60 x 18

ENVIRONMENTAL

Operating temperature (°C) DIRECTIVES & STANDARD

-20 / +50

EN, 61000-4-2 EN 300-220-1 V2-4-1, EN 301 489 V1-6-1 CE and RoHS recommendation compliant

ORDERING INFORMATION REFERENCE

MODEL DESCRIPTION

50-70-002

LoRaWANTM TIC SENSOR + 2S0

50-70-038

LoRaWANTM TIC SENSOR + 2S0 + 2 CURRENT TRANSFORMERS

© nkeWatteco - Head Quarter: rue Gutenberg, ZI Kerandré , 56700 Hennebont, France - Tel: 33 (0)2 97 36 10 12 Paris Office: 33, rue Pierre Marin, 91270 Vigneux sur Seine, France - Tel +33(0)1 69 52 28 31 For further information, please contact us: [email protected] - www.nke-watteco.com

LoRaWANTM TIC Sensor – V2.1 Updated 21/09/2017 - This document is the property of nke Watteco. Information contained within is not contractual and is susceptible to modifications without advance notice

RF TRANSCEIVER