SensoControl® Diagnostic Test Equipment for Hydraulics

Diagnostic Test Equipment for Hydraulics

All the instruments meet the guidelines of the European Community (EU). It is confirmed that these products are approved acc. to following standards.

DIN/EN 61000-6-2 DIN/EN 61000-6-3 Note! This document and other information from Parker Hannifin GmbH, provide product or system options for further investigation by users having technical expertise. Before you select or use any product or system it is important that you analyse all aspects of your application and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through his own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance and safety requirements of the application are met. The products are subject to change by Parker Hannifin GmbH at any time without notice. Technical subject to change. March 2010. © Copyright 2010, Parker Hannifin Corporation. All Rights Reserved.

Table of Contents Page Index

4

Product Overview

5

Measurement and Display

6-15

1

ServiceJunior

8-11

2

Serviceman

12-15

Measurement, Display and Storage

16-29

3

ServiceJunior wireless

16-20

4

The Parker Service Master Easy

21-25

5

The Parker Service Master Plus

26-31

6

Software SensoWin®

32-33

7

Electrical Signal Measurement

34-35 36-49

8

Pressure/Temperature/RPM Measurement SCPT Pressure/Temperature Sensors

9

SCPT-CAN Pressure/Temperature Sensors

41-42

10

SCT Temperature Sensors

43-46

11

SCPRM Tachometer

47-49 50-68

12

Volume Flow Measurement Turbine Flow Meter SCFT

13

Turbine Flow Meter SCFT-CAN

56-59

14

Hydraulic Tester SCLV

60-63

15

Flow Meter SCQ

64-68 69-72

16

Accessories SCK Connection Cable

17

SCA Adapter

71-72

SCKIT and Calibration Service

73-78

18

Equipment Case and SCKIT

73-76

19

Calibration Service

77-78

3

38-40

52-55

69-70

Catalogue 4054-2/UK

Index - Order Code K-SCFT-xxx-02-02  K-SCFT-xxx-C2-05 

77 77

K-SCJN-KIT-xxx  K-SCJN-xxx-01  K-SCJNP-KIT-xxx-RC  K-SCJNP-xxx-01-RC 

77 77 77 77

K-SCKIT-152-0-00  K-SCKIT-152-0-600  K-SCKIT-152-1-00  K-SCKIT-152-2-00  K-SCKIT-152-PQ  K-SCKIT-330-00  K-SCKIT-340-00  K-SCKIT-340-PTQ  K-SCKIT-500-00-00  K-SCKIT-500-01-00  K-SCKIT-500-01-01 

77 77 77 77 77 77 77 77 77 77 77

K-SCM-152-0-02  K-SCM-152-1-02  K-SCM-152-2-02  K-SCM-330-2-02  K-SCM-340-2-02  K-SCM-500-00-00  K-SCM-500-01-00  K-SCM-500-01-01 

77 77 77 77 77 77 77 77

K-SCPT-xxx-02-02  K-SCPT-xxx-02-02-PQC  K-SCPT-xxx-C2-05  K-SCPT-xxx-C2-05-PQC 

77 77 77 77

K-SCQ-xxx-0-02 

77

K-SCRPM-220 

77

K-SCT-150-0-02  K-SCT-150-04-02 

77 77

SC-910  SC-911  SC-912 

67 67 67

SC-BAT-340 

24

SCA-1/2-EMA-3  SCA-1/2-EMA-3-HP  SCA-1/2-PQC  SCA-1/4-EMA-3  SCA-1/4-PQC  SCA-90-EMA-3 

71 71 72 71 72 71

SCA-EMA-3/1  SCA-EMA-3/2  SCA-EMA-3/3  SCA-EMA-3/4  SCA-EMA-3/PQC  SCA-GMA3/20S/T 

71 71 71 71 72 46

SCAQ-060  SCAQ-150  SCAQ-GIR1/2A4CX 

67 67 67

SCC-340  SCC-500  SCC-DRV-300 

74 74 74

SCFT-150-DRV  SCFT-150-DRV-C2-05  SCFT-750-C2-05  SCFT-xxx-02-02  SCFT-xxx-C2-05 

63 63 59 55 59

SCJN-KIT-xxx  SCJN-xxx-01  SCJNA-PC  SCJNP-KIT-xxx-RC  SCJNP-xxx-01-RC 

74 9,74 74 74 17,74

SCK-002-08  SCK-102-02-08  SCK-102-03-02  SCK-102-05-02  SCK-102-05-12  SCK-315-02-34  SCK-318-05-21  SCK-401-0.3-Y  SCK-401-02-4F-4M  SCK-401-05-4F-4M  SCK-401-10-4F-4M  SCK-401-R 

69 69 68 68 68 24 24 70 70 70 70 70

SCKIT-152-0-00  SCKIT-152-0-600  SCKIT-152-1-00  SCKIT-152-2-00  SCKIT-152-PQ  SCKIT-330-00  SCKIT-340-00  SCKIT-340-PTQ  SCKIT-500-00-00  SCKIT-500-01-00  SCKIT-500-01-01 

75 75 75 75 75 75 75 75 76 76 76

SCLV-DISC-300  SCLV-DISC-800 

63 63

4

SCLV-PTQ-300  SCLV-PTQ-300-C2-05  SCLV-PTQ-750 

60 60 63

SCM-152-0-02  SCM-152-1-02  SCM-152-2-02  SCM-330-2-02  SCM-340-2-02  SCM-500-00-00  SCM-500-01-00  SCM-500-01-01 

12 12 12 24 24 31 31 31

SCMA-FCU-600  SCMA-VADC-600 

34 34

SCPT-xxx-02-02  SCPT-xxx-02-02-PQC  SCPT-xxx-C2-05  SCPT-xxx-C2-05-PQC 

40 40 42 42

SCQ-060-0-02  SCQ-150-0-02  SCQ-M24X1.5-ED  SCQ-M42X1.5-ED  SCQ-R1/2-ED  SCQ-R3/4-ED  SCQ-xxx-0-02 

67 67 67 67 67 67 51

SCRPM-220 

49

SCRPMA-001  SCRPMA-002 

49 49

SCSN-450 

24

SCT-150-0-02  SCT-150-04-02  SCT-400-K-01  SCTA-400-02 

46 46 46 46

SMA3-1500 

74

Catalogue 4054-2/UK

Product Overview Measurement and Display:

Measurement, Display and Storage:

ServiceJunior

Serviceman

ü Rugged, reliable and

ü Rugged, reliable and

simple to operate ü An outstanding priceperformance ratio

ü Automatic sensor

Page 8-11

Page 12-15

simple to operate recognition

ServiceJunior wireless

The Parker Service Master Easy

The Parker Service Master Plus

ü Wireless recording of

ü Automatic sensor recognition ü Up to 4 channels ü PC connection ü Software SensoWin®

ü Portable multi-function hand-held

Page 21-25

Page 26-31

measured values

ü Software JuniorWin®

Page 16-20 Software SensoWin®

Electrical Signal Measurement

ü Automate measurement

ü Frequency, current, voltage measurements ü e.g., for connecting external sensors

procedures, analyze and print-out documentation Page 32-33

Pressure/ Temperature/ RPM Measurement

SCPT-CAN Pressure/ Temperature Sensors

SCT Temperature Sensors

ü  Pressure/Temperature

ü  Pressure/Temperature

ü High-pressure-resistant ü No-contact speed

sensors with CAN-Bus

SCPRM Tachometer

temperature probes

measurements

Page 38-40

Page 41-42

Page 43-46

Page 47-49

SCFT Turbine Flow Meter

SCFT-CAN Turbine Flow Meter

SCLV Hydraulic Tester

SCQ Flow Meter

ü Turbine flow meter

ü CAN bus technology

ü Hydraulic tester

ü Flow meter

Page 52-55

Page 56-59

Page 60-63

Page 64-68

SCK Connection Cable

SCA Diagnostic Adapter

Equipment Case and SCKIT

Calibration Service

Zertifikat Nr.

3143

Beschreibung: Drucksensor Modell: SCPT-600-02-02 S/N: B1253S

Messbereich: 0...600 bar Genauigkeit: ± 0,5% FS

Referenz 1: Referenz 2:

Cal. No. NO94 DKD-KO5801 Cal. No. 8370831402

Budenberg S/N 15404 HP 3497A Data Logger

Nominal Soll (bar)

2,00 1,50 1,00 P [bar]

Accessories, Equipment Cases and Calibration Services

Page 34-35

SCPT Pressure/ Temperature Sensors

sensors

Volume Flow Measurement

measuring instrument with CAN bus connection ü Record, save and analyze measurements

0,50 0,00 -0,50 0

10

100

200

300

-1,00 -1,50 -2,00 P [bar]

ü Cable for CAN bus and ü Adapter to M16x2 analog sensors Page 69-70

400

600

Actual Ist (bar)

Deviation Abweichung (bar)

0

0

0,00

10

9,1

-0,90

100

99

-1,00

200

199,2

-0,80

300

299,5

-0,50

400

400

0,00

600

600,6

0,60

0

0,1

0,10

measurement system Page 71-72

5

Page 73-76

Page 77-78

Catalogue 4054-2/UK

SensoControl®  Long-term stability  Rugged design  Easy operation  Flexible use on site  Documentation of measured values

SensoControl® handmeters and complete measuring systems are perfectly suitable measuring tools for every application. Whether they are used in the industrial area, in mobile hydraulics, for service or repair: measuring and processing of hydraulic values is the basis of safe trouble shooting. The systematic search for errors with modern aids is something the service engineer simply cannot do without. High-speed processes, such as switching valves, cylinder strokes, pressure peaks, differential pressures and flow changes must be measured and evaluated simultaneously.

The SensoControl® handmeters have been specially developed for the following applications: n Measurement and display of all hydraulic values,

such as pressure, differential pressure, pressure peaks, temperature and flow, as well as speed. n They are perfectly suitable for the mobile recording

of measured values and feature high precision combined with easy operation. All measuring devices as well as their accessories are manufactured and tested in our own plants. Our ever-increasing insistence on quality and flexibility make Parker a reliable partner.

6

Catalogue 4054-2/UK

Finding the Best Product Measuring instruments with measured-value memory

Measurement and display

Choice/Features ServiceJunior

Serviceman

ServiceJunior wireless

The Parker Service Master Easy

The Parker Service Master Plus

Read out

ACT - MIN/MAX

ACT - MIN/MAX

ACT - MIN/MAX

ACT - MIN/MAX

ACT - MIN/MAX

(Peak-Hold)

FS

(Peak-Hold)

2 inputs







3 inputs







4 inputs







  

6 inputs









    

10 ms

2 ms

10 ms

1 ms/0,25 ms

1 ms/0,1 ms

Pressure





Differential pressure (P1-P2)



 



 

 

battery



battery









USB

USB

USB/Ethernet









Measuring and read out (Peak-Hold)

Additional inputs Pressure peaks

Functions Rechargeable battery Interface OnLine-Function Data recording











External power supply











Pressure

 —

Electrical signals



Auxiliary sensors



   



Temperature/RPM/Flow



   

Parker CAN bus sensors









    

Connection sensors



not available



optional



standard

7

— —

Catalogue 4054-2/UK

1 ServiceJunior

Product Specifications

 Digital pressure measurement and back-lit display  Accuracy ± 0,5 % FS  Display with bar graph (trailing indicator) with peak & hold function  Pressure peaks captured – 10 ms scanning rate  Easy operation  Long-term stability  Back-lit measured value display  Pressure ports stainless steel 1/4" BSPP

ServiceJunior Digital Pressure Gauge The ServiceJunior makes possible the measurement and display of pressures with one instrument. Measured values are shown with high precision on a 4-digit display. Pressure peaks are securely captured at a scanning rate of 10 ms. The ServiceJunior is distinctive through its very simple operation. With its convincing price to power ratio, the instrument offers all the advantages of digital pressure measurement.

8

Catalogue 4054-2/UK

1 ServiceJunior

Function Specifications 1 Trailing-indicator display with bar-graph due to peak & hold function

2 1

2 Actual value back-lit display (15 mm)

3 Battery level display 4 Display of MIN/MAX or Full Scale Range display (FS) 4 Menu functions 3



On/off switch Back-lit display



Minimum/maximum value/ FullScale

Menu: auto shut-off Choice of units Zero: Zero point correction

Delete MIN/MAX value Confirm menu function

ServiceJunior: ServiceJunior: Range: -1…016 bar/0...100 bar/0...400 bar/0...600 bar/0...1.000 bar

SCJN-xxx-01

1 ServiceJunior (acc. to pressure range) 2 batteries 1,5 V alkaline 1 adapter SCA-1/4-EMA-3

See page 77 for kits and equipment cases.

9

Catalogue 4054-2/UK

1 ServiceJunior

Pressure Measurement

ServiceJunior with adapter 1/4" BSPP female M16x2 female SCA-1/4-EMA-3

Adapter M16x2 male - M16x2 male

SCA-EMA-3/3

Test hose SMA3-xxx

Test hose SMA3-xxx Adapter EMA-3/xxx

10

Catalogue 4054-2/UK

1 ServiceJunior

Technical Data

Technical Data SCJN Range (bar)

Technical Data 016

100

400

600

1000

-1…16 0…100 0…400 0…600 0…1.000

Overload Pressure Pmax (bar)

40

200

800

1.200

1.500

Burst Pressure (bar)

50

800

1.700

2.200

2.500

Housing

Weight (g)

Ø = 79 mm; T = 33 mm Zinc die casting with rubber TPE protection cover 540

Port

Stainless Steel 1.4404 1/4“ BSPP (ISO 228-1)

Input

Sensor element ceramics (16 bar) Strain gauge pressure measurement cell 10 ms scanning rate Accuracy ± 0,25 % FS typ. ± 0,5 % FS max. + 0,2 %/year A/D converter 12 bit 4.096 steps resolution LC text display 4 1/2 digits 50x34 mm Digit size: 15 mm Units: mbar/bar/PSI/Mpa/kPa Back lit illumination Bar graph (trailing indicator) with peak & hold function (analog output on request) NBR

Display

Sealing

Parts in Contact with Stainless Steel 1.4404, NBR, Media ceramic Functions Units: mbar/bar/PSI/Mpa/kPa MIN/MAX - FullScale Battery level display Auto Power Off/On Zero (zero point equalization) Reset (Delete MIN/MAX) Power Supply 2 x 1,5V alkaline batteries Battery life typ. 1.500 h Ambient Temperature (°C)

-10...+50

Storage Temperature (°C)

-20...+60

Tmax Fluid (°C)

+80

Rel. Humidity

< 85 %

Protection

EN 60529 (IP 67)

Vibration

IEC 60068-2-6/10…500 Hz; 5 g IEC 600068-2-29/25 g; 11 ms

Shock Load

Reliability Cycles (10 ) 100 6

11

Catalogue 4054-2/UK

2 Serviceman

Product Specifications

 Easy operation  Prevention of measuring errors due to automatic sensor recognition  Printer and PC connection  Two-line display  Rugged design

The Serviceman has 2 inputs for sensors. This enables a differential pressure measurement by pressing only one key. Fast comparisons of actual and set values are done very easily. The Serviceman is extremely robust and insensitive to dirt, so that it can be used in even the toughest conditions. The digital display avoids reading errors. The Serviceman is small and light: perfect for mobile applications. Serviceman incl. external power supply 2 Inputs (5 pin) incl. PC Interface The data output can be used to connect a PC. Data printout is valid under the documentation obligatory under ISO 9001. The Min/Max memory permits the reading of peak values. Pressure peaks which could lead to damage are detected. Please note: The Serviceman cannot display negative pressures and flow volumes. If an SCPT sensor is connected, only the pressure signal could be displayed. For temperature measurment please use a separate sensor. Like all other SensoControl® measuring devices, the Serviceman is provided with sensor recognition. The measuring ranges are automatically scaled and units shown on the display. This avoids measuring errors and time-consuming adjustment work.

12

Catalogue 4054-2/UK

2 Serviceman 

Function Specifications Display



(two line) INP1 and INP2; ΔP display Battery level display On/off switch



Select button for input



Differential value display e.g. P1 - P2 = ΔP





Data transfer to PC



Delete MIN/MAX-readings INP1 = INP2: Equalisation of ΔP-measuring



Maximum value (pressure peaks)



Minimum value



Zero point equalisation

INP1/INP2

Sensor inputs 5-pin = push pull

24 VDC Power supply connection or automotive cable adapter SCK-318-05-21 RS232 Serviceman version

PC interface SCM-152-2-02

SCM-152-0-02

SCM-152-1-02

SCM-152-2-02

PC interface







110/240 VAC SCSN-450 power supply unit included in delivery







    

Replacement parts and accessories (must be ordered separately) Power supply

SCSN-450



Car cable adapter (12/24 VDC)

SCK-318-05-21



 

PC-connection cable (RS232)

SCK-315-02-31





Rechargable battery

SC-811



Battery

SC-812



 



not available



Option



Included

13



Catalogue 4054-2/UK

2 Serviceman

Software

PC-Software-Kit SCSW-KIT-152 PC-connection cable SCK-315-02-31 Serviceman SCM-152-2-02

Power supply SCSN-450

With the PC Software data transfer from Serviceman to PC or laptop is possible.

 Easy operation  Self running installation  On-line data recording  Storage of readings in MS Excel formate  Analysis of data with standard software  Print out readings on site

The software included is compatible with MS Windows 98/2000/XP. Recorded data can be further processed and analysed with standard software (e.g. MS Excel).

14

Catalogue 4054-2/UK

2 Serviceman

Technical Data Serviceman

SCM-152-0-02 SCM-152-1-02 SCM-152-2-02

Input

2 sensor inputs (5-pin) push-pull (Connection of auxiliary sensors with SCMA-VADC-600)







Connectable sensors

Pressure*, temperature, RPM, flow







Accuracy

±0,25 % FS ±1 Digit







Display

LC text display (4 digit), 2 line, digit size 8 mm







Interface

RS232 (4 pin) optional with a standard RS232/USB PC adapter







Functions

MIN-/MAX display Zero point equalisation INP1-INP2 differential reading Battery level display Auto power off (15 min)







Ambient conditions

Operating temperature: 0...+50 °C Storage temperature: -20...+60 °C Rel. humidity: < 85 % Protection acc. to (EN 60529) (IP54)







Power supply

External power supply SCSN-450 or car cable adapter SCK-318-05-21 (12/24 VDC) Internal battery 9 V/110 mA/h Battery life 5 h







Housing

ABS with rubber protection Dimensions: 170x78x51 mm (L/W/H ) Weight: 330 g







* negative pressure cannot be displayed —

not available



Included

15

Catalogue 4054-2/UK

3 ServiceJunior wireless

Product Specifications

 Digital pressure measurement and back-lit display  Displays pressure peaks (10 ms) both numerically and graphically  Measured value memory for storing pressure sequences (5000 measured values)  Transfer of the stored memory content of up to 16 devices to PC (USB) via radiowave interface  Analysis and modification of measured data with "JuniorWin" PC software Innovative memory technology ServiceJunior wireless is a real innovation: Pressure values can be measured, displayed and stored. The ServiceJunior wireless – with its unique, intelligent memory management – is capable to record individual or multiple pressure values from the machine or installation. Stored data is transmitted to a PC via distances of up to 150 meters. The "JuniorWin" PC could be used to set the limit value (REC Auto function) and the desired configuration. This allows applications under harsh conditions with up to 1000 bar working pressure. ServiceJunior wireless allows you to save time and costs when monitoring machines and installations comfortably from your plant office. Additionally you can analyse and archive the data on your PC. The device is ideal for monitoring, maintaining and servicing machines and installations in industrial and mobile hydraulic systems.

16

Catalogue 4054-2/UK

3 ServiceJunior wireless

Function Specifications 1 Trailing-indicator display with bar-graph due to peak & hold function 2 Actual value back-lit display (15 mm)

3 Battery level display 4 Display of MIN/MAX or Full Scale Range display (FS) 2

Menu functions 1

4 3



On/off switch Back-lit display



Minimum/maximum value/ FullScale

Menu: auto shut-off Choice of units Zero: Zero point correction

Delete MIN/MAX value Confirm menu function

ServiceJunior wireless ServiceJunior wireless (with radio-wave interface): Range: -1…016 bar/0...100 bar/0...400 bar/0...600 bar/0...1.000 bar

SCJNP-xxx-01-RC

1 ServiceJunior wireless (acc. to pressure range) 2 batteries 1,5 V alkaline 1 adapter SCA-1/4-EMA-3

See page 77 for kits and equipment cases.

17

Catalogue 4054-2/UK

3 ServiceJunior wireless 

Network Operations

The ServiceJunior wireless system  PC adapter for sending and receiving data (1)  Wireless transmission of parameters and data (Exporting the measured value memory)  Pressure monitoring for up to 16 measurement points (2-4)

 Long-term monitoring Damaging events can be documented. This enables quick and precise troubleshooting (peak pressure measurement).  Storage of measurement data Saves user-defined critical pressure ranges  Radio-wave transmission up to 150 meters Enables cable-free installation on difficult-to-reach sites (such as rotating equipment). The measured location and the location for recording measurements do not need to be close together.  Saves costs during diagnostics Simple and easy to install (battery operated, no cabling)

18

Catalogue 4054-2/UK

3 ServiceJunior wireless 

Memory Functions

Memory functions An example recording measurement with the REC Time/ REC Auto setting

REC Auto: Monitoring / control of pressure values All pressure values exceeding a limit value (e.g., 100 bar) are saved within a defined recording interval (e.g., 100 ms). 10 ms scanning rate = 10 measurements The maximum value (MAX) is determined from these measurement values and then saved.

REC Time: Recording time (e.g.) 300 s ÷ 5000 intervals – Interval = 60 ms 10 ms scanning rate = 6 measurements – The maximum value (MAX) is determined from these measurement values and then saved – 5000 (MAX) measured values are saved

1 = 101 bar 2 = 102 bar 3 = 108 bar MAX value This measured value is then saved for this interval (100 ms). All other measured values are deleted. … 9 = 105 bar 10 = 104 bar

19

Catalogue 4054-2/UK

3 ServiceJunior wireless 

Technical Data

Technical Data

Technical Data SCJNP Range (bar)

016

100

400

600

-1…16 0…100 0…400 0…600 0…1.000

Overload Pressure Pmax (bar)

40

200

800

1.200

1.500

Burst Pressure (bar)

50

800

1.700

2.200

2.500

Housing

Weight (g)

Ø = 79 mm; T = 33 mm Zinc die casting with rubber TPE protection cover 540

Port

Stainless Steel 1.4404 1/4“ BSPP (ISO 228-1)

Input

Sensor element ceramics (16 bar) Strain gauge pressure measurement cell 10 ms scanning rate Accuracy ± 0,25 % FS typ. ± 0,5 % FS max. + 0,2 %/year A/D converter 12 bit 4.096 steps resolution LC text display 4 1/2 digits 50x34 mm Digit size: 15 mm Units: mbar/bar/PSI/Mpa/kPa Back lit illumination Bar graph (trailing indicator) with peak & hold function (analog output on request) NBR

Display

Sealing

Parts in Contact with Stainless Steel 1.4404, NBR, Media ceramic Functions Units: mbar/bar/PSI/Mpa/kPa MIN/MAX - FullScale Battery level display Auto Power Off/On Zero (zero point correction) Reset (Delete MIN/MAX) PC-Function PC Software “JuniorWin” Download data from memory to PC via radio interface (2,4 GHz) Operation range 150 m (clear range) Setup of recording parameters IEEE 802.15.4 radio approval Memory Function 5.000 Readings (MAX pressure peaks) Setup of storage interval REC TIME (Time based recording) REC AUTO (Pressure spike monitoring) Power Supply 2 x 1,5V alkaline batteries Battery life typ. 800 h

1000

Ambient Temperature (°C)

-10...+50

Storage Temperature (°C)

-20...+60

Tmax Fluid (°C)

+80

Rel. Humidity

< 85 %

Protection

EN 60529 (IP 54)

Vibration

IEC 60068-2-6/10…500 Hz; 5 g IEC 600068-2-29/25 g; 11 ms

Shock Load

Reliability Cycles (10 ) 100 6

20

Catalogue 4054-2/UK

4 The Parker Service Master Easy

Product Specifications

 Instruments with 3-channel and 4-channel technology  Easy operation due to automatic sensor recognition  PC interface  Powered by rechargeable battery  Rugged design

The Parker Service Master Easy is a multi-channel hand meter for the simultaneous measuring of important hydraulic values: All hydraulic parameters such as pressure, differential pressure, flow and hydraulic power can be measured, displayed, stored and processed. To meet the requirements of both modern industrial hydraulics and complex mobile hydraulics, we offer a range of different models:

21

Catalogue 4054-2/UK

4 The Parker Service Master Easy

Function Specifications

Parker's portable measuring instruments can be used in three different versions: 1. Measuring and readout deviation of the pressure sensors relative to each other is corrected. For load sensing control the exact Δp setting is a prerequisite for trouble-free functioning of the hydraulics. A combination of Δp (bar) and flow Q (I/ min) is displayed as hydraulic power P (kW).

Through automatic sensor recognition all measured values are shown immediately on the display. Each input can be used as required. The display switches automatically to the appropriate line size.





Peak pressure measurement (MIN/ MAX display) The scanning rate of 1,000 measurement values/s captures rapidly occurring pressure peaks within the space of a millisecond.The Parker Service Master Easy can also be switched into fast mode.



External sensors Analog signals such as those from a force or stroke sensor (external sensor) can be measured using external modules. Electrical currents or voltages (like those from proportional valves) can also be captured.



Program-controlled recording Various programs may be selected:  Auto-trigger: Recording starts by pressure increase (60 bar, increasing slope)  Manual: Start by pressing enter key  Point-to-point measurements: Save individual measurements with the press of a button.

Differential pressure measurement Exact Δp measurement is achieved by means of the Δp adjustment. Under operating pressure the

2. Data logging and recording The recording (storage) of measurements provides documentation of settings and the actual condition of the hydraulics. Measurements can be further processed on a PC with SensoWin® software. This is ideal for customer care or service since the measurements can be called up at any time. With the special storage technology, all pressure peaks in the hydraulic system can be captured independently of the set measurement time (storage time). Within each storage interval one min. and one max. value is stored. The user has only to pre-select the measuring time. Individual setting of the storage interval is likewise available (for example, 10 ms).



Start-stop function The start and finish of measurements are controlled by the start/stop key only. The two buttons can be used to quickly and easily save the measured values. No additional default settings are needed.

Various save functions can be selected with the particular starting conditions. All the connected channels (sensors) are measured and stored. Program-controlled storage is particularly advantageous during the search for faults in hydraulic machinery. The point when the cause of damage occurs (for example, pressure peak or pressure drop) is not as a rule foreseeable. With the help of SensoWin® the recording can be subsequently analysed exactly.

3. OnLine Operation In On-line operation all measurement values are transferred directly to a PC and subsequently stored. The current graphic display in SensoWin® allows the hydraulics to be set (valve position or pressure load) whilst the test is running.

22

Catalogue 4054-2/UK

4 The Parker Service Master Easy

MAX

Function Specifications

MAX

250 bar

120 bar

MIN

MIN

50 bar 1

2 [min]

Dynamic MIN-MAX record/save: For each sensor (channel) up to 2,000 memory intervals could be created with The Parker Service Master Easy. Each memory interval saves a pair of data points consisting of one MIN and one MAX value.

Running a constant scanning rate of 1,000 readings/s this will correspond to 300 readings (interval). The highest (max) and lowest (min) will be carried to the measurements memory.

In a recording session of 10 min and 2,000 intervals, the length of each storage interval is 300 ms.

The connection of these data points creates a measured graph and guarantees the capture of pressure peaks.

MAX

MAX

250 bar

120 bar

MIN

MIN

50 bar 1

2 [min]

23

Catalogue 4054-2/UK

4 The Parker Service Master Easy

A





Function Specifications A

11-30 VDC Power supply 110/230 VAC-15 VDC Car cable adapter 12/24 VDC

B

I1 – I4 Sensor connection

C

PC (USB)

D

Display

E

Keyboard

B





C

D

ON/OFF

OK

ON/OFF Confirmation

function/value

Selection

of the function or value

STOP/ESC STOP



E

ESC

Menu keys ZERO IN1 = IN2

Zero-point correction Differential value alignment

MEM SET

Memory configuration Main menu (device settings)

LINE

DISP LINE

MIN-MAX/ACT or FS display Display configuration

REC

REC

Measured value recording

Reset

the MIN/MAX values

ZERO

MEM

DISP

RESET MIN/MAX

The Parker Service Master Easy with Power Supply SCSN/SensoWin Software/PC Cable The Parker Service Master Easy 3-channel The Parker Service Master Easy 4-channel

SCM-330-2-02 SCM-340-2-02

Spare Parts/Accessories Power Supply Car Cable Adapter PC-Connection Cable Rechargable battery

110/230 VAC EUR/UK/US 12/24 VDC USB

24

SCSN-450 SCK-318-05-21 SCK-315-02-34 SC-BAT-340 Catalogue 4054-2/UK

4 The Parker Service Master Easy

Technical Data

The Parker Service Master Easy Input

Accuracy

With sensor recognition (p/T/Q/n) Adapter for external sensors 0…10 V,  0/4…20 mA (Use SCMA-VADC-600 adapter for connecting external sensors.) Plug-in connection: 5-pin, push-pull Resolution: 12 bit + sign = 4,096 steps ±0,2 % FS ±1 Digit

Sampling period

1 ms 0,25 ms FAST MODE (IN1)

Display

Graphic LC Resolution: 128 x 64 pixels Visible area: 72 x 40 mm Back-lit display Digit size: 6 mm (for 4 line display) Accuracy of display: < 0,25 % FS Difference; addition; power; volumes ACT; MIN; MAX; FS; TEMP display; Battery status Foil-covered keyboard with mechanical tactile touch and embossed edges

Display functions

Operation Interface

Measured value memory

Ambient conditions

CE Power supply (external)

Battery Housing PC software

USB 2.0, compatible with USB 1.1 Min. 5 ms online data transmission ACT-MIN-MAX Measured value memory: 1000000 Points Curve memory: 240000 Points Data format ACT MIN-MAX FAST (0,25 ms) IN1 Memory configuration: Intervall (e. g. 5 ms) Points/Channel (2.000) Temperature range: 0 ... 50 °C Storage temperature: -25 °C ... 60 °C Temperature error: 0,02 % / °C Rel. humidity: < 80 % Protection according to: EN 60529 IP 54 (water spray/ oil) Drop test: IEC 60 DIN / EN 61000-6-2 DIN / EN 61000-6-3 11 … 30 VDC Power supply 110/240 VAC-15 VDC Car cable adapter (12/24 VDC) NiMH Battery life: about 8 hours with 3 sensors Polyamid; 235 x 106 x 53 mm; Weight: approx. 530 g Download, display and analyze measured data on PC Download and edit device settings Load device settings from library onto portable measuring instrument

25

Catalogue 4054-2/UK

5 The Parker Service Master Plus  Portable multi-function hand-held measuring instrument  Pressure, temperature, flow and speed can be measured, monitored and analysed.  Measurement and display of over 50 channels.  Measured value display: numerical, bar graph, pointer, curve graph  Project templates can be saved and loaded.  Interfaces: CAN, LAN, USB  Total memory with up to 1 billion measured values  Measured data can be (automatically) recorded, saved and analysed with the SensoWin® 7 PC software and a LAN or USB connection.

Product Specifications

The application possibilities for hydraulics have recently increased throughout all areas of drive and control systems. This trend has been particularly noticeable in the sectors of machine, plant and automotive construction. At the same time, hydraulics and electronics have become increasingly intertwined. Parker's new hand-held measuring instrument – The Parker Service Master Plus – helps you to deal with these new trends. It has never been so easy to follow the complex processes in these sectors with measurement, display and analysis. Potential uses include preventative maintenance, commissioning, troubleshooting and machine optimization. The expanded requirements of these modern applications (such as the increased number of measurement points, longer cable lengths and high noise immunity) have driven further development of the CAN bus. Parker's CAN bus sensors now take advantage of the bus system's automatic sensor detection capability to provide an easy-to-install Plug & Play solution. Compatibility with existing diagnostic sensors is also provided. Our proven storage strategy is focused on MIN and MAX value measurements. Combined with a wide variety of value presentation styles, these features make effective solutions-oriented analysis possible. The SensoWin® PC software offers additional methods for analysis, control and remote maintenance using LAN and USB connections. Together with this software, The Parker Service Master Plus is a truly user-friendly measuring instrument that can be used for any type of diagnostics application.

26

Catalogue 4054-2/UK

5 The Parker Service Master Plus

110/240 VAC power supply, battery life 8 hours, recharging time 3 hours

Function Specifications

Modular design for up to 16 analog channels or 2 Highspeed channels (0,1 ms) automatic sensor recognition

PC Interface (USB 2.0); ACT/MIN/MAX measured value transmission to the SensoWin® software, terminal for USB mass storage devices

2 x CAN-busnetworks with up to 32 channels

LAN interface for remote monitoring, micro SD memory card for storage enlargement

High protection from moisture and dirt thanks to cover caps and a rubber protective sleeve, Protection Class IP64

Easy to carry and hang up with carrying strap

Portable multi-function hand-held measuring instrument – strong in design and tough in operation

Large keyboard and fonts for easy operation and readability

Illuminated display for good readability in any situation

Ergonomic housing shape ensures convenient portability and long operating times

Protection of the housing, affording usage in tough environments and absorption of shocks

Big 5.7 inch colour display for clearly viewing the extensive information

Intuitive operation thanks to clear-cut control elements and function-oriented keys

27

Catalogue 4054-2/UK

5 The Parker Service Master Plus

Function Specifications Anschlusskabel Analog Analog connection cable SCK-102-XX-02 SCK-102-XX-02

Anschlusskabel CAN CAN connection cable SCK-401-XX-4F-4M SCK-401-XX-4F-4M

CAN pressure/temperature sensor Druck-/Temperatursensor CAN SCPT-XXX-C2-05 SCPT-XXX-C2-05

Analog Temperatursensor temperature sensor analog SCT-150-04-02 SCT-150-04-02

CAN Y-junction SCK-401-0.3-Y Y-Verteiler CAN SCK-401-0.3-Y

Analog ussturbine Durchfl analog flow turbine SCFT-XXX-02-02 SCFT-XXX-02-02

CAN terminating resistor Abschlusswiderstand CAN SCK-401-R SCK-401-R

Analog Druck-/Temperatursensor analog pressure/temperature sensor SCPT-XXX-02-02

n Display of measured values as figures and bars n Fixing of alarm ranges in green, yellow and red n Trailing pointer function with MIN and MAX values

n Up to 4 channels in one large-format display n Simultaneous display of ACT, MIN and MAX values n Information lines for current settings, events and views n Individual measurement channel identifier

n Up to 8 channels in one graph display n Fine, precise graph image thanks to high definition display n Choice between ACT and MIN/MAX value display n Automatic and manual scaling of the time axis for optimum measured value display

n Large-area pointer display of measured values n Trailing pointer for MIN and MAX values n Alarm range in green, yellow and red n Further channels can be called up with the arrow keys

28

n Up to 8 channels in one display n Colour allocation of the individual channels n Uniform headings with measurement titles, sensors connected, interfaces, date, time and battery condition indicator n Display can be changed between MIN and MAX values and full scale

Catalogue 4054-2/UK

5 The Parker Service Master Plus

Technical Data

The Parker Service Master Plus – Basic unit SCM-500-00-00 Inputs/outputs

Module slots

Display

Interfaces

CAN sensor inputs 2 CAN bus networks each with 16 channels (for Parker CAN-Bus sensors) Scanning rate 1 ms = 1000 measured values/sec. M12x1 push-in connector, 5-pin with SPEEDCON® 1 digital trigger input Scanning rate: 1 ms Input impedance: 1 kohm Active high: >+7 VDC…+24 VDC Active low: <1 VDC Isolated 1 digital trigger output Scanning rate: 1 ms Output signal: +24 VDC/max. 20 mA Isolated Push-in connector for digital input and output: M8x1, 4-pin, male 2, for input module, flexible placement possible Slot 1 = IN1, IN2, IN3, IN4/5 Slot 2 = IN6, IN7, IN8, IN9/10 FT-LCD colour graphic display Visible area: 115 x 86 mm Resolution: 640 x 480 pixels USB device Online data transmission between unit and PC via SensoWin® Measured value transmission: ACT/MIN/MAX USB standard: 2.0, fullspeed Push-in connector: USB socket, shielded, type B USB host Connection for mass storage devices such as USB stick or removeable hard disc Standard: 2.0, fullspeed,100 mA max. Push-in connection: USB socket, shielded, type A

Functions

Ethernet Online data transmission between unit and PC via SensoWin® and remote control Measured value transmission: ACT/MIN/MAX Standard: 10, 100 Mbit/s, IEEE 802.3 (10/100 base T) Push-in connection: RJ45, socket, shielded Measurement: ACT, MIN and MAX values Measured value display: Numerical, bar graph, pointer, curve graph Measuring functions: Start/stop, points, trigger Trigger: Slope, manual, level, window, time, logic (interconnection of up to two events for the measurement start and stop) Pre-Trigger Remote operation via the Ethernet Acoustic notification at any incident

SPEEDCON® Registered Trademark of PHOENIX CONTACT GmbH & Co. KG

29

Catalogue 4054-2/UK

5 The Parker Service Master Plus

Technical Data

The Parker Service Master Plus – Basic unit SCM-500-00-00 Measured value storage

For storing measured values, project data and screen copies (screenshots) Storage capacity ≤ 4 million measured values per measurement Total measured value storage > 1 billion measured values Storage format: ACT/MIN/MAX Storage interval: 1 ms to 24 h Storage duration: 1 ms to 300 h (trigger measurement) Internal 64 MB (approx. 32 million measured values) External: SD storage 2 GB (1 GB Micro SD memory card included in standard shipment) Slot: Micro SD memory card

Ambient conditions

Type of protection Power supply

Housing/protective sleeve (incl. in standard shipment)

External: USB mass storage device 40 GB Operating temperature: 0…+50 °C Storage temperature: -25…+60 °C Relative humidity: < 80 % Environmental test: IEC60068-2-32 (1 m, free fall) IP64 (to EN60529) Internal Lithium ion pack, +7.4 VDC/4500 mAh Battery charging circuit/operating time with 3 CAN sensors: > 8 h External 110/240 VAC - 24 VDC/2500 mA Vehicle adapter cable as accessory (12/24 VDC) Housing material: ABS/PC (thermoplastic) Housing protective sleeve material: TPE (thermoplastic elastomer) Dimensions (w x h x d): 257 mm x 75 mm x 181 mm Weight: 1550 g (basic model)

30

Catalogue 4054-2/UK

5 The Parker Service Master Plus

Technical Data

The Parker Service Master Plus – Typ 01 input modul Inputs with sensor recognition

Inputs for auxiliary sensors

Accuracy

3 sensor inputs (up to 6 analog measurement channels) with sensor recognition (p/T/Q/n) for SensoControl® diagnostic sensors also connection of auxiliary sensors possible with SCMA-VADC Push-in connection: 5-pin, push-pull, combination panel plug/socket Scanning rate: 1 ms = 1000 measured values/sec. For the SCPT combined pressure & temperature sensor, there is an additional temperature channel for each sensor input Temperature scanning rate: 1 s 2 analog sensor inputs for measuring current and voltage Scanning rate: 1 ms = 1000 measured values/sec. Voltage measuring range: -10…+10 VDC (freely configurable) Current measuring range: 0/4…20 mA Supply external sensors: +18…+24 VDC/max. 100 mA Push-in connection: M12x1, 5-pin socket FAST mode Scanning rate: 0.1 ms = 10,000 measured values/sec. only one auxiliary sensor input is useable ±0,25 % FS + 0,02 % per °C

Additional items available:

Product overview CANsensor inputs

Sensor inputs with sensor recognition (analog)

External sensor inputs (analog)

SCM-500-00-00 (Basic unit without input module)

2 networks each with 8 sensors max

0

0

SCM-500-01-00 (Basic unit with 1 input module type 01)

2 networks each with 8 sensors max

3

2

SCM-500-01-01 (Basic unit with 2 input modules type 01)

2 networks each with 8 sensors max

6

4

31

- Installed handle - 24VDC/2.5A power pack incl. country adapter - M8x1,4-pole cable socket - USB 2.0 cable (2 m) - LAN cable (5 m) - Operating instructions - PC Software - 1 GB microSDmemory card

Catalogue 4054-2/UK

6 Software SensoWin®

Product Specifications

 Easy operation  Windows® 2000/XP/ VISTA  Simultaneous representation of 16 curves  Zoom functions  Linking of measuring curves  Tabular listing of measured values  Calculation of extreme value  Curve shifting function  Free selection of units and measuring ranges  Cursor functions  Transmission of set-up parameters from The Parker Service Master  Automated measurement procedure and documentation print-out General

The SensoWin® software is an easy to operate software package for reading and processing the measured curves recorded by The Parker Service Master Easy or The Parker Service Master Plus. Documentation and certificates can be created easily and at low cost since SensoWin® can make use of all Windows features.

Functions Up to 16 different curves can be represented in a diagram. The curve shifting function allows exact hydraulics analysis. A power performance curve can be created to evaluate a pump. Leaks and pressure losses can be detected by generating a differential value function. With the cursor, a hydraulic procedure can be examined time-dependent. For each curve, extensive information is provided; The Parker Service Master Easy or The Parker Service Master Plus measurements can be reproduced at any time. The change of the ranges and units allows later adjustment for presentation in a diagram. Tabular presentation of ACT/MIN and ACT/MAX values, smoothing of the measurement curve and mathematical links are important functions in the analysis of the hydraulic system. Date and time are documented with each measurement. This considerably facilitates later allocation of values. Direct transmission of measured values from The Parker Service Master Easy or The Parker Service Master Plus to the PC is also possible. Current events (pressure peaks, etc.) are visible while the process is running (on-line function).

32

Catalogue 4054-2/UK

6 Software SensoWin®

Product Specifications The Parker Service Master

Software SensoWin®

Easy

Plus

Display: numerical, bar graph, pointer, curve graph





Simultaneous display of 16 channels





Oscilloscope / trigger display





Zoom function





Calculate function





Analyse function





Extended cursor function (Displays X values and corresponding Y values)





USB





Ethernet





Online measured-value display





Online measured-value memory





Projects can be saved





Excel export





Complete remote control of instrument





Measurement procedure can be automated (Auto-sequence control)





Connection via:

33

Catalogue 4054-2/UK

7 Electrical Signal Measurement 

with the SCMA-FCU/VADC

SCMA-FCU-600

SCMA-VADC-600

The Parker Service Master family or Serviceman

Measurement of electrical signals with The Parker Service Master

 Measuring frequency with the SCMA-FCU-600

 Measurement of external signals with the

The SCMA-FCU-600 can be used to connect frequency signals (for example, from turbines, flow counters or tachometers) to the The Parker Service Master Easy or the The Parker Service Master Plus. The instruments can process sinus and rectangle signals from 1 Hz to 5 kHz with signal amplitude from 20 mV to 10 V. Configuration is possible via USB and PC-software.

SCMA-VADC-600 Signals such as 0/4…20 mA or 0…10 V from auxiliary sensors, (for example, for torque, power or stroke) are connected to the TheParker Service Master.

 Power supply for the external sensor An external sensor can be supplied with 24 V using the SCMA-FCU-600.

 Analog or CAN output The SCMA-FCU-600 can be connected either to an analog input or a CAN input.

Typical applications:  Force/path diagram  Torque/flow volume nominal lines

 Current/voltage measurement Electric currents up to 4 ADC and voltages up to 48 VDC can be measured with this module. Applications: Current consumption of a proportional valve  Measurement of switch status in motors/pumps 

34

Catalogue 4054-2/UK

7 Electrical Signal Measurement 

with the SCMA-FCU/VADC

Technical Data SCMA-FCU-600

SCMA-VADC-600

Measuring range

1 Hz…5 kHz, Sinus and rectangle signals 40 mVpp...10 Vpp

Sensor power supply

24 VDC ±0,5 VDC

IOut (Max) without power supply

50 mA

Voltage Current 3 VDC 20 mA 10 VDC 200 mA 48 VDC 4.000 mA 18 VDC ±0,5 VDC For external voltages higher than 18 V DC: Power supply = sensor power supply 50 mA

IOut (Max) with power supply at 24 VDC

100 mA

100 mA

Accuracy

1 % FS ±0,05 %/°C

0,5 % FS ±0,02 %/°C 1,5 % FS at 4 A measurement range

Power Supply Power supply (external)

8 …24 VDC

11 …24 VDC

External power supply

4-pol., M8, plug (Female with screw-in connections included with delivery) 3-pol., female

4-pol., M12x1, female (Connection cable with banana jack included with delivery) 3-pol., female

USB

4-pol., female

-

Analog

5-pol., female

Fixed cable

CAN

5-pol., M12

-

114 x 64 x 26 mm

67 x 68 x 28 mm

Operating temperature

0 °C up to 60 °C

0 °C up to 60 °C

Storage temperature

-25 °C up to 70 °C

-25 °C up to 70 °C

Rel. Humidity

< 80 %

< 80 %

Protection class

IP40

IP40

External sensor port

Connections Sensor

Housing Dimensions Ambient conditions

35

Catalogue 4054-2/UK

Pressure/Temperature/RPM Measurement Various sensors are available depending on the measurement requirements.

1 SCPT-type pressure/temperature sensors     

Robust stainless steel design Response times of 1 ms Capturing of pressure peaks Accuracy ± 0,25 % typ. Diagnostic adapter

2 SCT-type temperature sensors  High-pressure-resistant temperature probe for hydraulic measurements  Measures oil temperatures up to 125°C  Screw-in or manual probe

3 SCPRM-type tachometer  Contactless RPM (speed) measurements  Measure up to 10000 RPMs  With 2-meter fixed cable

36

Catalogue 4054-2/UK

Pressure/Temperature/RPM Measurement SCPT

Overview

SCPT-CAN

SCT

SCRPM

Intended use

Measurement of pressure Measurement of pressure Measurement of pressure and temperature in standard and temperature in standard under high operating applications applications pressures

Contactless RPM (speed) measurements

ü  Stainless steel cell ü  Higher burst pressure ü  Resistant to pressure

ü  Unique resistance to

ü  Opto-electronic

pressures up to 630 bar ü  Compact size ü  Fast reaction time

ü  Installation or adjustment

-25…+125 °C

50…10.000 RPM

peaks

ü  Stainless steel cell ü  Higher burst pressure ü  Resistant to pressure peaks

measurement is not necessary

ü  CAN bus connection Measuring range

-1…15/0…60/150/400/ 600/1.000 bar

Hydraulic connection

1/2" BSPP

-1…16/0…60/160/400/ 600/1.000 bar

M10x1

Accuracy

< ±0,5 % FS

Electrical connection

5 pin push-pull

Application

Test bench, process engineering, materials handling, loading and lifting systems, general machinery construction and pneumatic or hydraulic installation construction

Order code

SCPT-xxx-02-02

SCPT-xxx-C2-05

SCT-150-xx-02

SCRPM-xxx

Refer to page

38-40

41-42

43-46

47-49

5 pin M12x1,5

37

< ±1 % FS

< ±0,5 % FS

5 pin push-pull

Fixed cable Mobile hydraulics/ Industrial conveyor vehicles/utility vehicles/construction machinery/ agricultural machinery

Catalogue 4054-2/UK

8 Pressure/Temperature Measurement SCPT      

Pressure/Temperature Sensors

Robust stainless steel design Response times of 1 ms Capturing of pressure peaks Accuracy ± 0,25 % typ. Flexible operation SCPT series

Fast response times guarantee the safe capture of pressure peaks in hydraulic systems. The robust stainless steel construction allows a variety of applications, for example cooling water or pneumatics. All pressure sensors are delivered with a diagnosis adapter (M16x2) installed. Connection to the hydraulic system takes place quickly and safely. Times for installation are reduced.

Pressure measurements -1... 015 bar

Pneumatics/ low pressure

0 ... 060 bar

Medium pressure

0 ... 150 bar

Medium pressure

0 ... 400 bar

Operating pressure hydraulics

0 ... 600 bar

High pressure

0 ... 1.000 bar

High pressure peaks

Temperature measurements -25...+105 °C

38

Oil temperature

Catalogue 4054-2/UK

Connection cable SCK-102-03-02

Function Specifications

Serviceman SCM-152-x-02

Pressure/Temperature sensor SCPT-xxx-02-02

The Parker Service Master Plus or The Parker Service Master Easy

Connection cable SCK-102-03-02

8 Pressure/Temperature Measurement SCPT

Adapter EMA-3/3

Test Hose SMA3-xxx

Test Hose SMA3-xxx

Adapter EMA-3/xxx

Diagnostic adapters All pressure sensors in a measurement case (kit) are provided with a factory-assembled SCA-1/2-EMA-3 diagnostic adapter. The pressure sensors can be adapted to all standard measuring connections with the help of diagnostic couplings supplied. They are perfectly suitable for a quick and flexible diagnoses in hydraulic applications.

Pressure/Temperature measurement SCPT There is a selection of various measuring ranges for the measuring of pressures. Sensors can be used for pneumatic applications and also for measuring pressure peaks up to 1000 bar. The pressure/temperature sensors of the SCPT series have a temperature channel which is retrieved via the TEMP key.

39

Catalogue 4054-2/UK

8 Pressure/Temperature Measurement SCPT

Technical Data

SCPT Pressure/Temperature Sensor 1/2" BSPP male incl. Adapter SCA-1/2-EMA-3

#

-1…015 bar/0…060 bar/0...150 bar/ 0...400 bar/0...600 bar/0...1.000 bar

ø27

SCPT-xxx-02-02

SCPT Pressure/Temperature Sensor 1/2" BSPP male incl. Adapter SCA-1/2-PQC

#

-1…015 bar/0…060 bar/0...150 bar/ 0...400 bar/0...600 bar

SCPT-xxx-02-02-PQC

SCK Connection cable Serviceman/The Parker Service Master Family

92

SW27 hex.27

SW30 hex.30

#

SW22 hex.22

3 m (male 5 pin - male 5 pin)

SCK-102-03-02

M16x2

5 m Extension (male 5 pin - female 5 pin)

SCK-102-05-12

SCPT-xxx-02-02

#

SCPT-015

SCPT-060

SCPT-150

SCPT-400

SCPT-600

SCPT-1000

-1…015

0…060

0...150

0...400

0...600

0...1.000

Overload Pressure Pmax (bar)

30

120

300

800

1.200

1.200

Burst Pressure (bar)

150

500

900

1.200

1.800

2.500

-25…+105

-25…+105

-25…+105

-25…+105

-25…+105

-25…+105

Measuring Range (bar)

Temperature Measuring Range (°C) Accuracy (± 1,5 %) FS FS = Full Scale Range

Accuracy

typ. ±0,25 % max. ±0,5 % + 0,2 %/year

Seal

FKM

Response Time (ms)

1

Ambient Temperature Range (°C)

-25…+80

Electrical connection

5 pin connector

Storage Temperature Range (°C)

-20...+80

Pressure Port Housing Weight (g)

1/2“ BSPP Stainless Steel 1.4301 200

Tmax Fluid (°C)

+105

Reliability Cycles (106)

100

Shock Load

40

IEC 68-2-29

Catalogue 4054-2/UK

9 Pressure/Temperature Measurement SCPT-CAN       

Pressure/Temperature Sensors

Robust stainless steel design Response times of 1 ms Capturing of pressure peaks State-of-the-art CAN bus technology Simple wiring with SPEEDCON® Long cable lengths up to 100 m Sensor identification LED (SIL)

All the advantages of the analog SCPT sensors are combined with state-of-the-art CAN bus technology. Simple wiring with up to 8 sensors on one bus cable and the SPEEDCON® quick-plug screw connection. Plug & Play functionality without much configuration efforts. All pressure sensors are delivered with a diagnosis adapter (M16x2) installed. Connection to the hydraulic system takes place quickly and safely. Times for installation are reduced.

Pressure measurements -1... 016 bar

Pneumatics/ low pressure

0 ... 060 bar

Medium pressure

0 ... 160 bar

Medium pressure

0 ... 400 bar

Operating pressure hydraulics

0 ... 600 bar

High pressure

0 ... 1.000 bar

High pressure peaks

Temperature measurements -25...+105 °C

Oil temperature

SPEEDCON® is a registered trademark of PHOENIX CONTACT GmbH & Co. KG

41

Catalogue 4054-2/UK

9 Pressure/Temperature Measurement SCPT-CAN SCPT Pressure/Temperature Sensor CAN 1/2" BSPP male incl. Adapter SCA-1/2-EMA-3

Technical Data #

-1…016 bar/0…060 bar/0...160 bar/ 0...400 bar/0...600 bar/0...1.000 bar

SCPT-xxx-C2-05

SCPT Pressure/Temperature Sensor 1/2" BSPP male incl. Adapter SCA-1/2-PQC

#

-1…016 bar/0…060 bar/0...160 bar/ 0...400 bar/0...600 bar

SCPT-xxx-C2-05-PQC

SCK Connection cable CAN The Parker Service Master Plus

#

2m

SCK-401-02-4F-4M

5m

SCK-401-05-4F-4M

10 m

SCK-401-10-4F-4M

#

SCPT-xxx-C2-05

SCPT-016

SCPT-060

SCPT-160

SCPT-400

SCPT-600

SCPT-1000

-1…016

0…060

0...160

0...400

0...600

0...1.000

Overload Pressure Pmax (bar)

32

120

320

800

1.200

1.200

Burst Pressure (bar)

150

500

900

1.200

1.800

2.500

Temperature Measuring Range (°C) Accuracy ±2K typ./±3K max.

-25…+105

-25…+105

-25…+105

-25…+105

-25…+105

-25…+105

Accuracy

typ. ±0,25 % max. ±0,5 % + 0,2 %/year

Ambient Temperature Range (°C)

-25…+85

Response Time (ms)

1

Storage Temperature Range (°C)

-25...+85

Electrical connection

5 pin, M12x1, connector

Measuring Range (bar)

Pressure Port Housing

1/2“ BSPP Stainless Steel 1.4301

Weight (g)

200

Seal

FKM

42

Tmax Fluid (°C)

+105

Reliability Cycles (106)

100

Shock Load

IEC 68-2-29

Vibration Resistance

IEC 68-2-6 10...500 Hz

Catalogue 4054-2/UK

10

Temperature Measurement SCT

 High pressure-proof temperature sensor for hydraulic measurements  Measurement of oil temperatures up to 125 °C  Flexible operation n Screw-in or manual sensor

In hydraulics, temperature measurements serve to locate faults and avoid the kind of damage caused by excessive oil temperatures in critical parts such as pumps and proportional valves. To get the exact temperature, the measurement is done directly in the tube or hose line. The screw-in sensors SCT-150 are compatible with flow measurement turbines SCFT-xxx-02-02.

43

Catalogue 4054-2/UK

Function Specifications

Serviceman SCM-152-x-02 or The Parker Service Master Family

Connection cable SCK-102-03-02

Connection cable SCK-102-03-02

Temperature Measurement SCT

S ens oC ontrol

IN-LINE Sensor SCT-150-04-02

SCT-150-0-02

Hand probe SCT-150-0-02

10

IN-LINE Adapter SCA-GMA3/20S/T

SCT-150 (-25°C...+125°C) Oil temperatures in tanks and containers are measured with the help of hand probe SCT-150-0-02 The temperature sensor SCT-150-04-02 can be adapted to the hydraulic system up to a system pressure of 630 bar. The male stud is compatible with the test points of the GMA3/20 series and with flow turbine SCFT-xxx.

44

Catalogue 4054-2/UK

Signal converter SCTA-400-02

Temperature Measurement SCT

Function Specifications

The Parker Service Master Plus or The Parker Service Master Easy

Thermocouple Sensor SCT-400-K-01

10

SCT-400-K-01 with signal converter SCTA-400-02 High temperature-proof thermocouple-sensors are used for the measurement of exhaust-gas temperatures up to 1,000 °C in diesel engines. The converter SCTA-400 is compatible with all thermocouple-sensors of the model K.

45

Catalogue 4054-2/UK

10

Temperature Measurement SCT

Technical Data

S ens oC ontrol

SCT-150-0-02

IN-LINE Sensor SCT-150-04-02 with IN-LINE adapter

Signal converter SCTA-400-02

SCT Temperature Sensor (Tmax = 125 °C)

#

IN-LINE Sensor (M10x1) with female Connector (5 pin) Hand Probe with female Connector (5 pin) IN-LINE Adapter Tube assembly Ø 20 (M10x1)

SCT-150-04-02 SCT-150-0-02 SCA-GMA3/20S/T

SCT Temperature Sensor (Tmax = 1.000 °C)

#

Converter Thermocouple 1000°C Thermocouple Sensor

SCTA-400-02 SCT-400-K-01

SCK Connection Cables Serviceman/The Parker Service Master Family

#

3 m (male 5 pin - male 5 pin) 5 m Extension cable (male 5 pin - female 5 pin)

SCK-102-03-02 SCK-102-05-12

SCT-150-04-02

Hand probe SCT-150-0-02

SCT-150-0-02

SCT-400-K-01

SCT-400-K-01

SCTA-400-02

-25...+125

-25...+125

0…+1.000

0…+1.000

±1,5 °C

±1,5 °C

±1,5 °C

±1,0 % FS

Response Time T0,9 (sec.)

13,5

9,1

≤5

-

Ambient Temperature (°C)

-25...+70

-25...+70

-20...+150

0...+50

Storage Temperature (°C)

-25...+80

-25...+80

-20...+80

-25...+60

Operating Pressure (bar)

630

-

-

-

Pmax (bar)

800

-

-

-

Measuring Range (°C) Accuracy

1.200

-

-

-

Steel C15K galvanized

Probe: Stainless Steel 1.4304 Grip: Delrin

Stainless Steel with 2 m fixed cable

ABS with 30 cm fixed cable

Seal

FKM

-

-

-

Weight (g)

100

120

150

-

Steel C15K galvanized, FKM

Stainless Steel 1.4304

Stainless Steel

-

Burst Pressure (bar) Housing

Parts in Contact with Media

FS = FullScale SCT Temperature Sensor (Tmax = 1.000 °C) not for Servicman

46

Catalogue 4054-2/UK

11

RPM Measurement SCRPM

 Contactless measurement of rotational speed  Measurement of rotational speed up to 10,000 rpm  With fixed cable 2 m

Rotational speed-depending data, such as delivery from a variable pump, are determined ideally in combination with the pressure and flow-test of a hydraulic drive. Contactless measurement (opto-electronic principal) can be done quickly and easily. Rotational speed is detected, for example, at a main drive shaft (e. g. power take-off shaft of a tractor), and displayed on the hand-held device. Installation or adjustment is not necessary.

For accurate acquisition of the opto-electronic signal, please use the supplied reflecting strips.

Rotating shaft non-contact measurement of rotational speed.

Cintact measurement of rotational speed with the contact adapter

Front face measurement of rotational speed with contact adapter.

47

For a shaft or belt, the rotational speed is measured directly with the contact adapter.

Catalogue 4054-2/UK

11

RPM Measurement

Function Specifications

Serviceman SCM-152-x-02

Tachometer SCRPM-220

The Parker Service Master Plus or The Parker Service Master Easy

48

Catalogue 4054-2/UK

11

RPM Measurement

Technical Data

Technical Data Input Measuring distance

25...500 mm

Measuring angle

± 45°

Type of measuring

optical, red LED

Output Measuring range

20...10.000 RPM

Accuracy

< 0.5 % FS

Resolution

± 5 RPM

Electrical connection Fixed cable 3 m

5 pin push-pull/4 pin

Ambient temperature

0...70 °C

General Material

ABS

Dimensions

∅ 34 mm/L = 130 mm

Weight

230 g

Tachometer SCRPM

FS = FullScale

Contact Adapter SCRPMA-001

Focusing Adapter SCRPMA-002

SCRPM Tachometer 20...10.000 RPM

SCRPM-220

Contact Adapter

SCRPMA-001

Focusing Adapter

SCRPMA-002

49

Catalogue 4054-2/UK

Volume Flow Measurement Depending on the measurement job to be done, various measuring instruments are available to the hydraulic technician:

1 Turbine flow meter type SCFT  Very low flow resistance  Built-in measurement points for pressure and temperature  Very simple installation into a hydraulic system  6 different measuring ranges up to 750 l/min.  Recording of a p/Q characteristic curve with a load valve to determine hydraulic performance

2 Hydraulik tester type SCLV    

High-pressure resistance up to 480 bar 2 Measuring ranges up to 750 l/min Integrated overload protection Reverse-mode operations

3 Flow meter type SCQ    

Flow measurement with direction indication Very fast reaction time < 2 ms Wide viscosity range Screw-in cartridge in connector block SCAQ

In addition to pressure measurement, the precise determination of flow volume in hydraulic equipment gives important evidence of the condition of the hydraulics. The efficiency of hydraulic drives such as hydrostatic units or variable pumps depends on the amount of flow. Hydraulic performance is determined by pressure and flow. The degree of wear in a hydraulic drive can be ascertained by comparing nominal and actual values. The resulting measurements can be used, for example, in preventive maintenance for systematic servicing and cost reductions. In mobile hydraulics, the efficiency of the machine is continually checked and documented. The diagnosis of pressure and flow thereby gives a total analysis.

50

Catalogue 4054-2/UK

Volume Flow Sensors 

Overview

SCFT Turbine Flow Meter

SCFT-CAN Turbine Flow Meter

SCLV Hydraulic Tester

SCQ Flow Meter

ü  Low-loss flow

ü  Low-loss flow

ü  Hydraulic tester

measurement

measurement

ü  For quick flow changes ü  Measures in both

ü  Response time

ü  Response time

Intended use

directions

ü  Response time

ü  Response time

≤ 50 ms

≤ 50 ms

ü  Various measurement ranges

≤ 50 ms

ü  Various measurement ranges

ü  Low flow resistance ü  Up to 750 l/min ü  Up to 420 bar ü  Reverse-mode operations

ranges

ü  Low flow resistance ü  Up to 750 l/min ü  Up to 420 bar ü  Reverse-mode operations

ü  Low flow resistance ü  Up to 750 l/min ü  Up to 420 bar ü  With integrated PQ

≤ 2 ms

ü  Reverse-mode operations

ü  Wide range of viscosities ü  Compact size ü  Up to 420 bar

measurement

ü  CAN bus connection

Measuring range

ü  Various measurement

ü  Load valve ü  Overload protection 10...300/20…750 l/min

-60 …+60 l/min -150…+150 l/min

Ports

1,0...15/3...60/5...150/ 8...300/15...600/ 20…750 l/min 1/2"…1 1/4" BSPP

1/2"…1" BSPP

Measuring process

Turbine

Turbine

M24/M42 Cartridge Block SCAQ-XXX Spring/piston principle

Accuracy

< ±1 % FS Response time ≤ 50 ms

Applications

< ±1 % FS < ±2 % FS Response time Response time ≤ 50 ms ≤ 2 ms Test bench, general machinery construction and hydraulic installation construction

Order code

SCFT-xxx-02-02

SCFT-xxx-C2-05

SCLV-PTQ-xxx

SCQ-xxx-0-02

Refer to page

52-55

56-59

60-63

64-68

51

Catalogue 4054-2/UK

12

Turbine Flow Meter SCFT

 Measurement principle: flow turbine  6 flow ranges up to 750 l/min  Simple installation  Resistant to high pressure up to 480 bar  Low flow resistance  Built-in pressure and temperature measurement points  Suitable for reverse operation

Flow measurement with low flow resistance combined p/T/Q measurement Function A turbine wheel is driven by the oil flow. The frequencies thus produced are processed by digital electronics. The influence of turbulent flow effects is compensated for. Because of the low flow resistance QR the hydraulic circuit operates with very low losses.

USCITA

FLUSSO

For pressure measurement the turbine is equipped with an EMA-3 test point.

SENSORE MAGNETICO

Oil temperatures are measured direct in the oil flow. Consequently all the important measurement parameters are available at one measuring location.

TURBINA ASSIALE

Applications • mobile diagnosis p-Q measurement in construction and agricultural machines hydraulic tests with load valves automatic scaling

SENSO ROTAZIONE

52

Catalogue 4054-2/UK

The Parker Service Master Plus or The Parker Service Master Easy

Function Specifications

Connection Cable SCK-102-03-02

Turbine Flow Meter SCFT

Connection Cable SCK-102-03-02

12

Serviceman SCM-152-x-02

SCFT Turbine Flow Meter SCFT-xxx-02-02

53

Catalogue 4054-2/UK

Turbine Flow Meter SCFT

Dimensional Drawings

E

12

C

FLOW

A

B Q

R

N

P

M S

#

SCFT-015

SCFT-060

SCFT-150

SCFT-300

SCFT-600

SCFT-750

A

37

62

62

62

62

100

B

136

190

190

190

212

212

C

37

50

50

50

75

75

E

117

130

130

134

150

154

M

70

103

103

103

127

126

N

0

5

5

7

9

10

P

25

50

50

52

62

60

Q

N/A

92

92

90

106

104

R

0

5

5

9

11

10

S

115

157

157

150

168

181

54

Catalogue 4054-2/UK

12

Turbine Flow Meter SCFT #

Technical Data

SCFT-015

SCFT-060

SCFT-150

SCFT-300

SCFT-600

SCFT-750

Flow Range QN (l/min)

1…015

3…060

5...150

8...300

15...600

20...750

Accuracy (± %) FS/IR @ 21cSt.

1,0 FS

1,0 IR*

1,0 IR*

1,0 IR*

1,0 IR*

1,0 IR*

350

350

350

350

290

400

1/2“ BSPP

3/4“ BSPP

3/4“ BSPP

1“ BSPP

1-1/4“ BSPP

1-7/8“ UNF

Pressure Drop ΔPmax (bar) @ FS, 21cSt

1,5

1,5

1,5

4

5

5

Weight (g)

650

750

750

1200

1800

2100

Operating Pressure PN (bar) Ports (A - B)

FS = FullScale IR = Indicated Reading * = for measurements ≥ 15 % FS, for measurements < 15 % FS accuracy 0.15 % FS

50

Response Time (ms) Qmax (l/min)

QN x 1,1

Overload Pressure Pmax (bar)

PN x 1,2

Ports: Temperature Port (SCT-150) Pressure Port (EMA3 Fitting) Pressure Port (VSTI)

M10x1 OR M16x2 1/4“ BSPP

Housing

Aluminium

Sealing

FKM

Parts in Contact with Media *

Ambient Temperature (°C)

-10...+50

Storage Temperature (°C)

-20...+80

T Fluid (°C)

-20...+90

Filtration (µm)

Viscosity Range (cSt.)*

Aluminium, Steel, FKM

25 (10 µm for SCFT-015)

10...100

(calibrated at 21 cSt, other viscosities on request)

SCFT Turbine Flow Meter

#

1,0...15/3...60/5...150/8...300/15...600/20…750 l/min

SCFT-xxx-02-02

SCK Connection Cables

#

Serviceman/The Parker Service Master Family 3 m (male 5 pin - male 5 pin)

SCK-102-03-02

5 m (male 5 pin - male 5 pin)

SCK-102-05-02

5 m Extension cable (male 5 pin - female 5 pin)

SCK-102-05-12

55

Catalogue 4054-2/UK

13

Turbine Flow Meter SCFT-CAN

 Flow turbine with CAN bus technology  6 flow ranges up to 750 l/min  Simple installation  Resistant to high pressure up to 480 bar  Low flow resistance  Built-in pressure and temperature measurement points  Suitable for reverse operation  Simple wiring with SPEEDCON®  Long cable lengths up to 100 m

Flow measurement with low flow resistance combined p/T/Q measurement USCITA

FLUSSO

Function A turbine wheel is driven by the oil flow. The frequencies thus produced are processed by digital electronics. The influence of turbulent flow effects is compensated for. Because of the low flow resistance QR the hydraulic circuit operates with very low losses.

SENSORE MAGNETICO

For pressure measurement the turbine is equipped with an EMA-3 test point.

TURBINA ASSIALE

Oil temperatures are measured direct in the oil flow. Consequently all the important measurement parameters are available at one measuring location.

Applications • mobile diagnosis with The Parker Service Master Plus p-Q measurement in construction and agricultural machines hydraulic tests with load valves automatic scaling

SENSO ROTAZIONE

SPEEDCON® is a registered trademark of the PHOENIX CONTACT GmbH & Co. KG

56

Catalogue 4054-2/UK

Function Specifications

Connection Cable SCK-1401-02-4F-4M

Turbine Flow Meter SCFT-CAN

The Parker Service Master Plus or The Parker Service Master Easy

SCFT Turbine SCFT-xxx-C2-05 B P

Q

R

N

13

M S

57

Catalogue 4054-2/UK

Turbine Flow Meter SCFT-CAN

Dimensional Drawings

C

E

13

A B Q

R

N

P

M S

SCFT-CAN –#

015

060

150

300

600

750

A

36,9

62

62

62

62

100

B

136

190

190

190

212

212

C

36,9

49,6

49,6

49,6

75

75

E

150

164

164

168

183

186

M

69,5

103

103

103

127

125,8

N

0

5

5

7

9

12

P

25

52

52

52

62

60

Q

/

90

90

90

106

104

R

0

5

5

9

11

10

S

115

157

157

152

168

181

58

Catalogue 4054-2/UK

13

Turbine Flow Meter SCFT-CAN SCFT-CAN -#

Technical Data

015

060

150

300

600

750

Flow Range QN (l/min)

1…015

3…060

5...150

8...300

15...600

20...750

Accuracy (± %) FS/IR @ 21cSt.

1,0 FS

1,0 IR*

1,0 IR*

1,0 IR*

1,0 IR*

1,0 IR*

350

350

350

350

290

400

1/2“ BSPP

3/4“ BSPP

3/4“ BSPP

1“ BSPP

1-1/4“ BSPP

1-7/8“ UNF

Pressure Drop ΔPmax (bar) @ FS, 21cSt

1,5

1,5

1,5

4

5

5

Weight (g)

650

750

750

1200

1800

2100

Operating Pressure PN (bar) Ports (A - B)

FS = FullScale IR = Indicated Reading * = for measurements ≥ 15 % FS, for measurements < 15 % FS accuracy 0.15 % FS

50

Response Time (ms) Qmax (l/min)

QN x 1,1

Overload Pressure Pmax (bar)

PN x 1,2

Ports: Temperature Port (SCT-150) Pressure Port (EMA3 Fitting) Pressure Port (VSTI)

M10x1 OR M16x2 1/4“ BSPP

Housing

Aluminium

Sealing

FKM

Parts in Contact with Media *

Ambient Temperature (°C)

-10...+50

Storage Temperature (°C)

-20...+80

T Fluid (°C)

-20...+90

Filtration (µm)

Viscosity Range (cSt.)*

Aluminium, Steel, FKM

25 (10 µm for SCFT-CAN-015)

10..100

(calibrated at 21 cSt, other viscosities on request)

SCFT-CAN Turbine Flow Meter

#

1,0...15/3...60/5...150/8...300/15...600 l/min

SCFT-xxx-C2-05

20…750 l/min; Pmax = 480 bar

SCFT-750-C2-05

SCK Connection Cables CAN The Parker Service Master Plus

#

2m

SCK-401-02-4F-4M

5m

SCK-401-05-4F-4M

10 m

SCK-401-10-4F-4M

59

Catalogue 4054-2/UK

14

Hydraulikc Tester SCLV

 Measurement principle: Measuring instrument for pressure, temperature and flow volume 2 measurement ranges up to 750 l/min Resistant to high pressure up to 480 bar Integrated overload protection Reverse-mode operations (Direction of flow A - B)  Also with CAN bus connection

   

Precise measurements of flow, pressure and temperature Special features: • Easy to use in both flow directions; integrated oil bypass protects the system, testing device and operator from surge pressures • User-selectable flow direction enables smooth connections and simple measurements • Can be put into use quickly with pumps, valves, motors, cylinders and hydrostatic drives

The hydraulic testers are designed for testing the functionality of motors, pumps, valves and hydrostatic drives. These hydraulic testers are easy to handle and capable of locating errors in a hydraulic system. This can help you in reducing outage times and performing preventative maintenance. These hydraulic testers can be used for precisely measuring flow, pressure and temperature. The testers can also be helpful when performing hydraulic system maintenance, locating error sources on directional control valves and making valve adjustments. The pressure-load valve with its integrated bypass-blow-out discs makes it possible to build up pressure progressively in order to check the flow in an entire working area. Integrated safety shut-off (Blow-out discs) The load valve is fitted with two safety blow-out discs. The device is protected by this safety mechanism. These discs will break and the load valve will become inactive whenever the maximum allowed operating pressure (Pmax) is exceeded. The complete flow then runs off to the tank. Read carefully through the operating manual before replacing the blow-out discs.

60

Catalogue 4054-2/UK

14

Hydraulic Tester SCLV

Function Specifications

Measurement of pressure, flow and temperature using The Parker Service Master Easy or Plus and hydraulic-tester SCLV-PTQ

FLOW

SERIAL No. XXXXX RANGE 10-300 LPM / 3-80 US GPM

The p-Q diagram (to the right) shows the power determined. Especially in hydraulic pump (load sensing) systems the speed-dependent load is important to analyze. The evaluation in SensoWin® will be done quickly and simply.

The hydraulic power of a system can be analyzed by a combined measurement of pressure and flow (to the left). The diagram shows an application with a hydraulic-tester SCLV-PTQ. Pressure in the system is generated by the integrated loading valve. In the evaluation power will be calculated from the flow volume and pressure of the pump.

61

Catalogue 4054-2/UK

14

Hydraulic Tester SCLV

Dimensional Drawings SCFT-150-DRV

E

E

SCLV-PTQ-xxx

C

C

FLOW FLOW

SERIAL No. XXXXX RANGE 10-300 LPM / 3-80 US GPM

B

A

B

#

#

SCFT-150-DRV

SCLV-PTQ-300

SCLV-PTQ-750

A

62

98

117

B

370

222

235

C

50

50

75

E

130

135

150

SCFT-150-DRV

SCLV-PTQ-300

SCLV-PTQ-750

6…150

10…300

20…750

Accuracy (± %) IR @ 21cSt.

1,0

1,0 (> 20 l/min)

1,0 (> 25 l/min)

Operating Pressure PN (bar)

350

350

400



420 bar

480 bar

3/4“ BSPP

1“ BSPP

1-7/8“ UNF

Pressure Drop Δ Pmax (bar) @ (FS) 21cSt.

15

4

5

Weight (kg)

4,2

5,5

8,9

Accuracy QN (l/min)

Safety shut-off (Blow-out disc) Ports (A - B)

FS = FullScale IR = Indicated Reading

Response Time (ms)

50

Qmax (l/min)

QN x 1,1

Overload Pressure Pmax (bar)

PN x 1,2

Ports: Temperature Port (SCT-150) Pressure Port (EMA3 Fitting) Pressure Port (VSTI)

M10x1 OR M16x2 1/4“ BSPP

Housing

Aluminium

Sealing Parts in Contact with Media

Ambient Temperature (°C)

-10...+50

Storage Temperature (°C)

-20...+80

T Fluid (°C)

-20...+90 25

Filtration (µm)

FKM Viscosity Range (cSt.)*

Aluminium, Steel, FKM *

62

10...100

(calibrated at 21 cSt, other viscosities on request)

Catalogue 4054-2/UK

14

Hydraulic Tester SCLV

Technical Data #

SCLV-PTQ Hydraulic Tester with Load Valve 10…300 l/min, Pmax = 420 bar

SCLV-PTQ-300

10…300 l/min, Pmax = 420 bar, with CAN bus connection

SCLV-PTQ-300-C2-05

20...750 l/min, Pmax = 480 bar

SCLV-PTQ-750

20...750 l/min, Pmax = 480 bar, with CAN bus connection

SCLV-PTQ-750-C2-05

SCLV-PTQ Safety Blow-Out Discs

#

10…300 l/min, Pmax = 420 bar

SCLV-DISC-300

20...750 l/min, Pmax = 480 bar

SCLV-DISC-800

SCFT Flow-Turbine incl. Pressure Control Valve with Non Return Protection 6...150 l/min; Pmax = 400 bar

# SCFT-150-DRV

6...150 l/min; Pmax = 400 bar, with CAN bus connection

SCFT-150-DRV-C2-05

SCK Connection Cables

#

Serviceman/The Parker Service Master Family 3 m (male 5 pin - male 5 pin)

SCK-102-03-02

5 m (male 5 pin - male 5 pin)

SCK-102-05-02

5 m Extension cable (male 5 pin - female 5 pin)

SCK-102-05-12

SCK Connection Cables CAN The Parker Service Master Plus

#

2m

SCK-401-02-4F-4M

5m

SCK-401-05-4F-4M

10 m

SCK-401-10-4F-4M

63

Catalogue 4054-2/UK

15

Flow Meter SCQ

 Measurement principle: spring/piston system  Flow measurement with direction indication  Response time < 2 ms  Compact design  Withstands pressures up to 420 bar  Wide range of viscosity  p/T/Q measurement possible with connection block

Flow measurement with direction indication for mobile and stationary measurement jobs Function When there is a flow from A to B or B to A, the piston (K) is moved. When at rest, the spring (F) and piston (K) are in equilibrium. The stroke change (S) is proportional to the flow volume and is converted by the built-in electronics to a measured value. By the change in direction of the piston (B to A) flow directions can be shown (e.g. –45.8 l/min.). The response time of the piston movement is less than 0.002 s.

Application In the field of high pressure hydraulics, the rapid capture of the amount of flow is of great significance. The reaction times of the SCQ’s enable the dynamic behaviour of hydraulic systems to be measured. The indication of direction is helpful when searching for faults in hydraulic systems. Rapid load changes, which can cause damage for example in valves and pumps, can be determined. Installation with a connection block permits the combined measurement of p, T and Q. Rapid assembly of the SCQ’s is achieved with an in-line adapter for tube or hose installation. SCQ measurement principle

Robust design makes possible extreme condition applications, such as, for example, high load changes or rates of pressure increase.

64

Catalogue 4054-2/UK

15

Flow Meter SCQ

Function Specifications

ON/OF F

RESET

INP 1/2

MA X

1-2

MIN

P R INT

ZE R O

S ervic eman

INP 1

Connection Cable SCK-102-03-02

R S 232

Serviceman SCM-152-x-02

Flow Meter SCQ-060-0-02

Connection Cable SCK-102-03-02

The Parker Service Master Plus or The Parker Service Master Easy

S C M-152

INP 2 24V DC

A

A

B

B

Flow Meter SCQ in Connection Block SCAQ

Flow Meter SCQ with Temperature Sensor SCPT in Connection Block SCAQ

65

Catalogue 4054-2/UK

15

Flow Meter SCQ

Dimensional Drawings

Port dimensions and pressure drop graph SCQ-060 Tightening torque 20 Nm

77

50x30

SW27 hex27

ca. 68

X1) X2) X4)

x1) O-Ring 21,95x1,78 x2) O-Ring 20,29x2,2 x3) O-Ring 15,54x2,62 x4) O-Ring

X3) M24x1.5

Port dimensions and pressure drop graph SCQ-150 Tightening torque 30 Nm

77

50x30

SW27 hex27

ca. 97

X1)

X2)

M42x1.5

x1) O-Ring 36,17x2,62 x2) PTFE with O-Ring 2,64x2,62

66

Catalogue 4054-2/UK

15

Flow Meter SCQ

Dimensional Drawings

Connection Block SCAQ-060 60

Connection Block SCAQ-150

75

30

80

58

10

30

120 68

42

M6

8

38

80

A

B

Y

19

60

60

B

44

ø6.5

A

40

8.5

10

20

8 tief

X M8

15

20 tief

42.5

10

55

2.1

0.5

44

G1/2 ø28.5

2.1

1.3

IN-LINE Adapter SCAQ-GIR1/2 G3/4

G1/4

ø34

ø16

36

100

SCQ Flow Meter (0...±60 l/min)

#

0...60 l/min (incl. Distance ring)

SCQ-060-0-02

Distance ring (O-Ring SCQ-060)

SC-910

Seals for SCQ-060

SC-911

SCAQ IN-LINE Adapter (60 l/min)

#

1/2" BSPP female (A-B) und M24 female for SCQ-060

SCAQ-GIR1/2A4CX

with Screw Plugs: Cartridge Port M24 male (SCQ-060)

SCQ-M24X1.5-ED

SCAQ Block (60 l/min)

#

1/2" BSPP female (A-B) und M24 female for SCQ-060

SCAQ-060

with Screw Plugs: Cartridge Port M24 male (SCQ-060)

SCQ-M24X1.5-ED

1/2" BSPP male port (A-B)

SCQ-R1/2-ED

SCQ Flow Meter (0...±150 l/min)

#

0...150 l/min

SCQ-150-0-02

Seals for SCQ-150

SC-912

SCAQ Block (150 l/min)

#

3/4" BSPP female (A-B) und M42 female for SCQ-150 with Screw Plugs: Cartridge Port M24 male (SCQ-060)

SCAQ-150 SCQ-M42X1.5-ED

3/4" BSPP male port (A-B)

SCQ-R3/4-ED

67

Catalogue 4054-2/UK

15

SCQ Flow Meter SCQ

Technical Data

SCQ-060

SCQ-150

Flow Range QN

-60...+60 l/min

-150...+150 l/min

Qmax

-66...+66 l/min

-165...+165 l/min

Ports

M24 (NG10)

M42 (NG16)

Weight (g)

670

1.050

Accuracy

Ambient Conditions

Deviation from Characteristic Curve ±2 % FS @ 46cSt.

Operating Temperature

+10…+60 °C

Response Time

2 ms

Storage Temperature

-20…80 °C

Thermal Drift

±0,05 % FS/°C

Tmax Fluid (°C)

+80 °C

Repeat Accuracy

±0,5 % FS

Filtration

25 µm

Viscosity Range

15…100 cSt. IP54 DIN EN 60529

Resistance to Pressure Pressure Range

3…420 bar

Protection

Operating Pressure PN

315 bar

Electrical Connection to Hand-Held Measuring Instrument

Overload Pressure Pmax

420 bar

Plug connection

5-pin, push-pull

Pressure Drop ∆P (bar) @ (FS)

see diagram

Power Supply

+7…+15 VDC

Output

±3 VDC

Material Housing

Steel

Electromagnetic Compatibility

Sealing

NBR

Interference Emissions

EN 61000-6-3

Parts in Contact with Media

Steel, NBR

Interference Resistance

EN 61000-6-2

FS = FullScale

SCK Connection Cables

#

Serviceman/The Parker Service Master Family 3 m (male 5 pin - male 5 pin)

SCK-102-03-02

5 m (male 5 pin - male 5 pin)

SCK-102-05-02

5 m Extension cable (male 5 pin - female 5 pin)

SCK-102-05-12

68

Catalogue 4054-2/UK

16

Connection Cable SCK

 Compact size  Interference-free  Compatible with all diagnostic sensors and diagnostic measuring instruments  Push-Pull plug  Various lengths available  Oil-resistant material

Cable for CAN bus sensors Parker CAN bus cables are used to connect Parker CAN bus sensors to the The Parker Service Master Plus SCM-500. The quick-plug screw connection SPEEDCON* makes connecting simple and secure.

Cable for analog sensors The SensoControl® diagnostics cable was designed for use in harsh working conditions.

CAN connection cable SCK-401-02-4F-4M

4-pole version Diagnostic cables with 4-pole plugs are only compatible with the Serviceman types SCM-150-1-01/02 and SCM152-2-08.

CAN Y-junction SCK-401-0.3-Y

Connection cable (5-pin) SCK-102-xx-02

5-pole version The 5-pole cables with push-pull plugs fit to all 5-pole connections.

Extension cable (5-pin) SCK-102-05-12 CAN terminating resistor SCK-401-R

Adapter SCK-002-08 (for connecting a 4-pin sensor to a newer device)

Connection cable (4-pin) SCK-102-02-08 * SPEEDCON® is a registered trademark of der Firma PHOENIX CONTACT GmbH & Co. KG

69

Catalogue 4054-2/UK

16

Connection Cable SCK 

Technical Data

Housing Material

Cu alloy

Surface

chrom plated

Protection class (while plugged-in)

IP50

Cable Sheathing

PUR

Colour

black

Permissible temperatures

for stationary operations for non-stationary operations

Shielding

-20 … +70 °C -5 … +70 °C Cu meshed shield

SCK Connection Cables

#

Serviceman/The Parker Service Master Family 3 m (male 5 pin - male 5 pin)

SCK-102-03-02

5 m (male 5 pin - male 5 pin)

SCK-102-05-02

5 m Extension cable (male 5 pin - female 5 pin)

SCK-102-05-12

Adapter (female 4 pin - male 5 pin)

SCK-002-08

2 m (4 pin) is only for the older versions of the Serviceman (SCM-150-1-01/02 and SCM-152-2-08)

SCK Connection Cables CAN* The Parker Service Master Plus

SCK-102-02-08

#

2 m (male 5 pin - female 5 pin)

SCK-401-02-4F-4M

5 m (male 5 pin - female 5 pin)

SCK-401-05-4F-4M

10 m (male 5 pin - female 5 pin)

SCK-401-10-4F-4M

CAN Y-splitter incl. 0,3 m cable

SCK-401-0.3-Y

CAN terminating resistor** (female 5 pin - female 5 pin)

SCK-401-R

* Other lengths available on request. ** Each CAN network requires a terminating resistor.

70

Catalogue 4054-2/UK

17

Diagnostic Adapter SCA Diagnostic adapter

S1

S2

Technical Data

#

Pmax

PBerst

T1

T2

1.000 bar 1.200 bar 2.000 bar 1/4" BSPP

L1 S1 S2

M16x2

32

27

22

800 bar 1.200 bar 1/2" BSPP

M16x2

36

30

22

SCA-1/2-EMA-3-HP 1.000 bar 1.200 bar 2.000 bar 1/2" BSPP

M16x2

36

32

22

T1

T2

SCA-1/4-EMA-3

PN

SCA-1/2-EMA-3

630 bar

L1

T1

90° Diagnostic adapter with coupling L1

# S2

PN

Pmax

630 bar

PBerst

T1

T2

L1

L2 S1 S2

49

26

800 bar 1.200 bar M16x2 M16x2

19

22

T2

SCA-90-EMA-3

S1 L2

Diagnostic couplings S1

T1

#

L1

SCA-EMA-3/1 S2

PN

Pmax

SCA-EMA-3/1

630 bar

PBerst

T1

T2

800 bar 1.200 bar

M16x2

--

L1 S1 S2 37

17

--

M12x1.65 31

SCA-EMA-3/2

630 bar

800 bar 1.200 bar

M16x2

17

17

SCA-EMA-3/3

630 bar

800 bar 1.200 bar

M16x2

M16x2

43

17

--

SCA-EMA-3/4

630 bar

800 bar 1.200 bar

M16x2

M16x1.5

31

17

17

T2

T1

S1

L1

SCA-EMA-3/2

T1

T1

S1

L1

SCA-EMA-3/3 S1

T2

T1

S2

L1

SCA-EMA-3/4

Please pay attention to pressure range!

71

Catalogue 4054-2/UK

17

Diagnostic Adapter SCA

Technical Data

Parker Diagnostic quick couplings

S1

T1

#

L1

PN

Pmax

PBerst

T1

T2

L1 S1 S2

SCA-1/4-PQC

400 bar

600 bar 1.000 bar 1/4" BSPP

--

--

--

--

SCA-1/2-PQC

400 bar

600 bar 1.000 bar 1/2" BSPP

--

59

27

--

SCA-EMA-3/PQC

400 bar

600 bar 1.000 bar

--

78

21

17

M16x2

SCA-1/2-PQC S1

T1

S2

L1

SCA-EMA-3/PQC

Please pay attention to pressure range!

72

Catalogue 4054-2/UK

18

Kits and Equipment Cases for Parker Portable Measuring Instruments

 Sturdy and tough equipment case  Easy operation  Automatic sensor recognition  PC connection  Not dependent on main power supply

The Parker Service Master Easy-Kit

Parker hand-held measuring instruments meet the requirements of modern industrial hydraulic systems as well as those of complex mobile hydraulics. They are indispensable for maintenance of hydraulic systems. All hydraulic parameters, such as differential pressure, flow and hydraulic power can be measured, displayed and processed. Serviceman-Kit This allows precise diagnostics in mobile hydraulics as well as in construction and agricultural machinery. Quick and convenient troubleshooting is also possible. Furthermore, comparisons between set and actual values can be made and documented. Parker hand-held measuring instruments are an ideal tool for all service technicians who need simple hydraulic test equipment for mobile as well as industrial hydraulics. With the SensoWin® software, the data can be processed on a PC.

ServiceJunior-Kit

73

Catalogue 4054-2/UK

18

Kits and Equipment Cases for Parker Portable Measuring Instruments

SCC Equipment Case to carry following components 2x Service Junior or 1x Service Junior wireless with PC-Adapter or Serviceman 2x SCK/2x SCPT/2x SMA3

SCC-340 SCC-DRV-300

Serviceman/The Parker Service Master Easy 6x SCK/8x SCPT/1x SCT/1x SCRPM 1x SCFT015/060/150/300/600 or 1x SCFT-150-DRV The Parker Service Master Plus and 1x The Parker Service Master Easy or 1x Serviceman 12x SCK/ 8x SCPT/ 1x SCT/ 1x SCRPM 1x SCFT-015/060/150/300/600/750 or 1x SCFT-150-DRV

ServiceJunior-Kits Range: -1…016 bar/0...100 bar/0...400 bar/0...600 bar 1 Equipment Case 1 ServiceJunior with adapters: 1 1/4 BSPP female - M16x2 female 1 M16x2 male - M16x2 male 1 Test Hose 1.500 mm (M16x2)

SCC-500

SCJN-KIT-xxx* SCC-340 SCJN-xxx-01 SCA-1/4-EMA-3 SCA-EMA-3/3* SMA3-1500*

ServiceJunior wireless-Kits Range: -1…016 bar/0...100 bar/0...400 bar/0...600 bar 1 Equipment Case 1 ServiceJunior wireless 1 PC-Adapter incl. Software with adapters: 1 1/4 BSPP female - M16x2 female 1 M16x2 male - M16x2 male 1 Test Hose 1.500 mm (M16x2)

SCJNP-KIT-xxx-RC* SCC-340 SCJNP-xxx-01-RC SCJNA-PC SCA-1/4-EMA-3 SCA-EMA-3/3* SMA3-1500*

* not available for 1.000 bar

74

Catalogue 4054-2/UK

18

Kits and Equipment Cases for Parker Portable Measuring Instruments

Serviceman-Kits

#

#

#

SCKIT-152-0-600

SCKIT-152-0-00

SCKIT-152-1-00

SCKIT-152-2-00

1

1

1

1

SCM-152-0-02

SCM-152-0-02

SCM-152-1-02

SCM-152-2-02

Equipment Case SCC-340 Serviceman Pressure/Temperature Sensor 0 … 600 bar SCPT-600-02-02 Connection Cable 3 m SCK-102-03-02 Adapter (M16x2 male - M16x2 male) SCA-EMA-3/3 Test Hose 1.500 mm (M16x2) SMA3-1500 PC-Cable (RS-232) SCK-315-02-31

#

Please order accessories (SCPT/SCT/SCFT/SCRPM) separate!

1 1

2

2

2

1

2

2

2

1

2

2

2

--

--

--

1

The Parker Service Master Easy-Kits

#

#

SCKIT-330-00

SCKIT-340-00

Equipment Case SCC-DRV-300

1

1

The Parker Service Master Easy

SCM-330-2-02

SCM-340-2-02

Connection Cable 3 m SCK-102-03-02

3

2

Connection Cable 5 m SCK-102-05-02 Adapter (M16x2 male - M16x2 male) SCA-EMA-3/3 Test Hose 1.500 mm (M16x2) SMA3-1500

--

2

2

2

2 2 Please order accessories (SCPT/SCT/SCFT/SCRPM) separate!

Serviceman-p-Q-Kit

#

The Parker Service Master Easy-p-Q-Kit Equipment Case SCC-DRV-300 Serviceman

#

SCKIT-152-PQ

SCKIT-340-PTQ

1

1

SCM-152-2-02

--

--

SCM-340-2-02

The Parker Service Master Easy Pressure/Temperature Sensor 0… 600 bar SCPT-600-02-02 Temperature Sensor SCT-150-04-02

1

2

--

1

Flow Turbine SCFT-150-DRV

1

1

Connection Cable 3 m SCK-102-03-02

2

2

Connection Cable 5 m SCK-102-05-02 Adapter (M16x2 male - M16x2 male) SCA-EMA-3/3 Test Hose 1.500 mm (M16x2) SMA3-1500

--

2

1

2

1

2

75

Catalogue 4054-2/UK

18

Kits and Equipment Cases for Parker Portable Measuring Instruments

The Parker Service Master Plus-Kits

#

#

#

SCKIT-500-00-00

SCKIT-500-01-00

SCKIT-500-01-01

1

1

1

SCM-500-00-00

SCM-500-01-00

SCM-500-01-01

Neck Strap SC-ACC-01

1

1

1

CAN Connection Cable SCK-401-05-4F-4M

2

2

2

Terminating Resistor CAN SCK-401-R

2

2

2

Connection Cable 3 m SCK-102-03-02



2

3

Connection Cable 5 m SCK-102-05-02 Adapter (M16x2 male - M16x2 male) SCA-EMA-3/3 Auxiliary Sensor Adapter SCK-401-4M Test Hose 1.500 mm (M16x2) SMA3-1500



1

3

2

2

2



1

2

2

2

2

Equipment Case SCC-500 The Parker Service Master Plus

76

Catalogue 4054-2/UK

19

Calibration Services

Diagnostic Products with Calibration Certificate ISO 9001 When requested, new instruments can be delivered with a calibration certification in compliance with ISO 9001. Instrument/Type/Kit ServiceJunior ServiceJunior wireless

# K-SCJN-xxx-01 K-SCJNP-xxx-01-RC

ServiceJunior-Kits ServiceJunior wireless-Kits

K-SCJN-KIT-xxx K-SCJNP-KIT-xxx-RC

Serviceman

K-SCM-152-0-02 K-SCM-152-1-02 K-SCM-152-2-02

Serviceman-Kits

K-SCKIT-152-0-600 K-SCKIT-152-0-00 K-SCKIT-152-1-00 K-SCKIT-152-2-00

The Parker Service Master Easy

K-SCM-330-2-02 K-SCM-340-2-02 K-SCKIT-330-00 K-SCKIT-340-00

The Parker Service Master Easy-Kits The Parker Service Master Plus

K-SCM-500-00-00 K-SCM-500-01-00 K-SCM-500-01-01 K-SCKIT-500-00-00 K-SCKIT-500-01-00 K-SCKIT-500-01-01

The Parker Service Master Plus-Kits

Serviceman-p-Q Kit The Parker Service Master Easy-p-Q Kit

K-SCKIT-152-PQ K-SCKIT-340-PTQ

SCPT Pressure/Temperature Sensor SCPT Pressure/Temperature Sensor PQC

K-SCPT-xxx-02-02 K-SCPT-xxx-02-02-PQC

SCPT-CAN Pressure/Temperature Sensor SCPT-CAN Pressure/Temperature Sensor PQC

K-SCPT-xxx-C2-05 K-SCPT-xxx-C2-05-PQC

SCRPM Tachometer

K-SCRPM-220

SCFT Flow Turbine

K-SCFT-xxx-02-02

SCFT-CAN Flow Turbine

K-SCFT-xxx-C2-05

SCQ Flow Transducer

K-SCQ-xxx-0-02

SCT Temperature Sensor

K-SCT-150-0-02 K-SCT-150-04-02

77

Catalogue 4054-2/UK

19

Calibration Services

Example Certificate Nr. 3143 Description:: Model: S/N:

Pressure Sensor SCPT-600-02-02 B1253S

Operating Range: Accuracy:

Reference 1: Reference 2:

Budenberg S/N 15404 HP 3497A Data Logger

Cal. No. NO94 DKD-KO5801 Cal. No. 8370831402

Nominal (bar)

2,00 1,50 P [bar]

...600 bar ± 0,5% FS

Actual (bar)

Deviation (bar)

1,00

0

0

0,00

0,50

10

9,1

-0,90

100

99

-1,00

200

199,2

-0,80

300

299,5

-0,50

400

400

0,00

600

600,6

0,60

0,00 -0,50 0

10

100

200

300

400

600

-1,00 -1,50 -2,00 P [bar]

78

Catalogue 4054-2/UK

Parker’s Motion & Control Technologies At Parker, we’re guided by a relentless drive to help our customers become more productive and achieve higher levels of profitability by engineering the best systems for their requirements. It means looking at customer applications from many angles to find new ways to create value. Whatever the motion or control technology need, Parker has the experience, breadth of product and global reach to consistently deliver. No company knows more about motion and control technology than Parker. For further information call 00800 27 27 5374

FLUID & GAS HANDLING Key Markets • Aerospace • Agriculture • Bulk chemical handling • Construction machinery • Food & beverage • Fuel & gas delivery • Industrial machinery • Mobile • Oil & gas • Transportation • Welding Key Products • Brass fittings & valves • Diagnostic equipment • Fluid conveyance systems • Industrial hose • PTFE & PFA hose, tubing & plastic fittings • Rubber & thermoplastic hose & couplings • Tube fittings & adapters • Quick disconnects

AEROSPACE Key Markets • Aircraft engines • Business & general aviation • Commercial transports • Land-based weapons systems • Military aircraft • Missiles & launch vehicles • Regional transports • Unmanned aerial vehicles Key Products • Flight control systems & components • Fluid conveyance systems • Fluid metering delivery & atomization devices • Fuel systems & components • Hydraulic systems & components • Inert nitrogen generating systems • Pneumatic systems & components • Wheels & brakes

HYDRAULICS Key Markets • Aerospace • Aerial lift • Agriculture • Construction machinery • Forestry • Industrial machinery • Mining • Oil & gas • Power generation & energy • Truck hydraulics Key Products • Diagnostic equipment • Hydraulic cylinders & accumulators • Hydraulic motors & pumps • Hydraulic systems • Hydraulic valves & controls • Power take-offs • Rubber & thermoplastic hose & couplings • Tube fittings & adapters • Quick disconnects

CLIMATE CONTROL Key Markets • Agriculture • Air conditioning • Food, beverage & dairy • Life sciences & medical • Precision cooling • Processing • Transportation Key Products • CO2 controls • Electronic controllers • Filter driers • Hand shut-off valves • Hose & fittings • Pressure regulating valves • Refrigerant distributors • Safety relief valves • Solenoid valves • Thermostatic expansion valves

PNEUMATICS Key Markets • Aerospace • Conveyor & material handling • Factory automation • Life science & medical • Machine tools • Packaging machinery • Transportation & automotive Key Products • Air preparation • Brass fittings & valves • Manifolds • Pneumatic accessories • Pneumatic actuators & grippers • Pneumatic valves & controls • Quick disconnects • Rotary actuators • Rubber & thermoplastic hose & couplings • Structural extrusions • Thermoplastic tubing & fittings • Vacuum generators, cups & sensors

ELECTROMECHANICAL Key Markets • Aerospace • Factory automation • Life science & medical • Machine tools • Packaging machinery • Paper machinery • Plastics machinery & converting • Primary metals • Semiconductor & electronics • Textile • Wire & cable Key Products • AC/DC drives & systems • Electric actuators, gantry robots & slides • Electrohydrostatic actuation systems • Electromechanical actuation systems • Human machine interface • Linear motors • Stepper motors, servo motors, drives & controls • Structural extrusions

PROCESS CONTROL Key Markets • Chemical & refining • Food, beverage & dairy • Medical & dental • Microelectronics • Oil & gas • Power generation Key Products • Analytical sample conditioning products & systems • Fluoropolymer chemical delivery fittings, valves & pumps • High purity gas delivery fittings, valves & regulators • Instrumentation fittings, valves & regulators • Medium pressure fittings & valves • Process control manifolds

FILTRATION Key Markets • Food & beverage • Industrial machinery • Life sciences • Marine • Mobile equipment • Oil & gas • Power generation • Process • Transportation Key Products • Analytical gas generators • Compressed air & gas filters • Condition monitoring • Engine air, fuel & oil filtration & systems • Hydraulic, lubrication & coolant filters • Process, chemical, water & microfiltration filters • Nitrogen, hydrogen & zero air generators

SEALING & SHIELDING Key Markets • Aerospace • Chemical processing • Consumer • Energy, oil & gas • Fluid power • General industrial • Information technology • Life sciences • Military • Semiconductor • Telecommunications • Transportation Key Products • Dynamic seals • Elastomeric o-rings • EMI shielding • Extruded & precision-cut, fabricated elastomeric seals • Homogeneous & inserted elastomeric shapes • High temperature metal seals • Metal & plastic retained composite seals • Thermal management

Parker Worldwide AE – UAE, Dubai Tel: +971 4 8127100 [email protected]

FR – France, Contamine s/Arve Tel: +33 (0)4 50 25 80 25 [email protected]

RO – Romania, Bucharest Tel: +40 21 252 1382 [email protected]

AR – Argentina, Buenos Aires Tel: +54 3327 44 4129

GR – Greece, Athens Tel: +30 210 933 6450 [email protected]

RU – Russia, Moscow Tel: +7 495 645-2156 [email protected]

HK – Hong Kong Tel: +852 2428 8008

SE – Sweden, Spånga Tel: +46 (0)8 59 79 50 00 [email protected]

AT – Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0 [email protected] AT – Eastern Europe, Wiener Neustadt Tel: +43 (0)2622 23501 900 [email protected] AU – Australia, Castle Hill Tel: +61 (0)2-9634 7777 AZ – Azerbaijan, Baku Tel: +994 50 2233 458 [email protected] BE/LU – Belgium, Nivelles Tel: +32 (0)67 280 900 [email protected] BR – Brazil, Cachoeirinha RS Tel: +55 51 3470 9144 BY – Belarus, Minsk Tel: +375 17 209 9399 [email protected] CA – Canada, Milton, Ontario Tel: +1 905 693 3000 CH – Switzerland, Etoy Tel: +41 (0) 21 821 87 00 [email protected] CL – Chile, Santiago Tel: +56 2 623 1216 CN – China, Shanghai Tel: +86 21 2899 5000

HU – Hungary, Budapest Tel: +36 1 220 4155 [email protected] IE – Ireland, Dublin Tel: +353 (0)1 466 6370 [email protected]

SK – Slovakia, Banská Bystrica Tel: +421 484 162 252 [email protected]

IN – India, Mumbai Tel: +91 22 6513 7081-85

SL – Slovenia, Novo Mesto Tel: +386 7 337 6650 [email protected]

IT – Italy, Corsico (MI) Tel: +39 02 45 19 21 [email protected] JP – Japan, Tokyo Tel: +(81) 3 6408 3901 KR – South Korea, Seoul Tel: +82 2 559 0400 KZ – Kazakhstan, Almaty Tel: +7 7272 505 800 [email protected] LV – Latvia, Riga Tel: +371 6 745 2601 [email protected] MX – Mexico, Apodaca Tel: +52 81 8156 6000 MY – Malaysia, Shah Alam Tel: +60 3 7849 0800

CZ – Czech Republic, Klecany Tel: +420 284 083 111 [email protected]

NL – The Netherlands, Oldenzaal Tel: +31 (0)541 585 000 [email protected]

DE – Germany, Kaarst Tel: +49 (0)2131 4016 0 [email protected]

NO – Norway, Ski Tel: +47 64 91 10 00 [email protected]

DK – Denmark, Ballerup Tel: +45 43 56 04 00 [email protected]

NZ – New Zealand, Mt Wellington Tel: +64 9 574 1744

ES – Spain, Madrid Tel: +34 902 330 001 [email protected] FI – Finland, Vantaa Tel: +358 (0)20 753 2500 [email protected]

SG – Singapore Tel: +65 6887 6300

TH – Thailand, Bangkok Tel: +662 717 8140 TR – Turkey, Istanbul Tel: +90 216 4997081 [email protected] TW – Taiwan, Taipei Tel: +886 2 2298 8987 UA – Ukraine, Kiev Tel +380 44 494 2731 [email protected] UK – United Kingdom, Warwick Tel: +44 (0)1926 317 878 [email protected] US – USA, Cleveland Tel: +1 216 896 3000 VE – Venezuela, Caracas Tel: +58 212 238 5422 ZA – South Africa, Kempton Park Tel: +27 (0)11 961 0700 [email protected]

PL – Poland, Warsaw Tel: +48 (0)22 573 24 00 [email protected] PT – Portugal, Leca da Palmeira Tel: +351 22 999 7360 [email protected]

European Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, UK, ZA)

© 2010 Parker Hannifin Corporation. All rights reserved.

Edition: May 2010/CAT/4054-2/UK Scriptor/Thieme MediaCenter Zwolle

Your local authorized Parker distributor